![PFT 00260621 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/pft/00260621/00260621_operating-instructions-manual_1535709066.webp)
Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Operation
5
1
3
2
4
6
Figure 94: Switching on the machine
again
Operation 400V
1. Push the metal bracket (1) in the opposite direction.
2. Turn the main reversing switch (2) to position "I".
3. Press the green pushbutton (3) control voltage "ON".
4. Switch on the air compressor using the green toggle switch.
5. Turn the booster pump selector switch (4) to the "AUTO" position.
6. Turn the star wheel selector switch (5) to the "1" position.
7. Turn the pump motor selector switch (6) to "right" position.
8. Let the machine run for a short while without mortar hoses.
9. As soon as material flows out of the pressure flange, switch the
pump motor selector switch (6) to the "0" position.
10.Apply wallpaper paste to the cleaned mortar hoses and connect to
the machine and spray gun.
11.Turn the pump motor selector switch (6) to "right" position.
12.The machine starts again as soon as the air tap at the spray gun is
re-opened.