![PFT 00260621 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/pft/00260621/00260621_operating-instructions-manual_1535709032.webp)
Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Operation
5.1.4
Safety system
1
Figure 26: Inclination switch
Inclination switch (1) in the terminal box of the geared motor.
The inclination switch triggers as soon as the quick closure is
opened and the geared motor is tilted on the side.
If the machine in on rough terrain, the inclined position of the
machine can also trigger the inclination switch.
5.1.5
Mortar pressure gauge
Figure 27: Mortar pressure gauge
WARNING
Operating pressure too high!
Machine parts can open in an uncontrolled manner and
injure the operator.
Do not operate the machine without mortar pressure
gauge.
Only use mortar hoses with a permissible operating
pressure of at least 40 bar.
The burst pressure of the mortar hose must reach at
least 2.5 times the value of the operating pressure.
5.2
Inspection by machine operator
Prior to each shift, the machine operator has to examine the effec-
tiveness of the control and safety devices, as well as the proper
fitting of the protection devices.
The safe working condition of construction machinery has to be
checked by the machine operator during operation.
If the safety devices show any defects or if any other defects are
detected that compromise a safe operation, the supervisor has to
be informed immediately.
In case of defects that cause harm to persons, the operation of the
construction machine has to be stopped to eliminate the defects.
5.3
Preparing the machine
Prior to operating the machine carry out the following steps for
preparing the machine:
page 32 / 80