Measures in case of risk of frost
62
2016-02-17
48 Measures in case of risk of frost
ATTENTION!
Damage by frost!
Water that expands inside the machine during frost
can cause severe damage.
Therefore:
The following steps are to be carried out if the
machine stands still in case of risk of frost.
Fig. 105: Disconnect water supply
1. Remove the water hose (1) from the water inlet.
2. Remove the water hose (2) from the water nozzle at the rubber
mixing section.
Fig. 106: Remove the agitator
3. Remove the agitator (3) from the mixing zone.
4
Fig. 107: Open the drain tap
4. Open the drain taps (4) at the fittings block.
5. Let the water flow and close drain taps again.