![PFT 00 06 49 61 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/pft/00-06-49-61/00-06-49-61_operating-manual_1535704037.webp)
Mixing pump RITMO L / RITMO M Overview - Operation
Monitoring the machine
2016-02-17
37
30 Monitoring the machine
DANGER!
Access by unauthorised persons!
The machine must be operated only if monitored.
31 Putting the machine into operation
31.1 Check consistency of mortar
Fig. 50: Consistency test tube
1. Connect consistency test tube at the mortar pressure gauge.
2. Place a bucket or pan under the consistency test tube.
Article number: 20104301 Consistency test tube 25m piece
31.2 Start RITMO L in “flying mode”
2
4
3
Fig. 51: Switching on
1. Close the control circuit by inserting the plug (1) in the control
cabinet.
2. Turn the selector switch (2) to the “With water” position towards
the left.
3. Turn poti (3) for motor speed / material quantity to position 7
(adjust as required).
4. Turn the selector switch (4) directions of rotation of the pump
motor clockwise (machine starts).
5. Check material consistency at the consistency test tube.
6. Switch off the machine at selector switch (4) (centre position).
7. Remove consistency test tube and clean it.
1