Care and Maintenance
12 - 3
12
.04
Checking/adjusting the air pressure
●
Before operating the machine, always
check the air pressure on gauge
1
.
●
Gauge
1
must show a pressure of
6 bar
.
●
If necessary adjust to this reading.
●
To do so, pull knob
2
upwards and turn it
so that the gauge shows a pressure of
6
bar
.
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
Fig. 12 - 04
12
.05
Cleaning the air filter of the air-filter/lubricator
Switch the machine off!
Disconnect the air hose at the
air-filter/lubricator.
To drain water bowl
1
:
●
Water bowl
1
drains itself automatically
when the compressed-air hose is discon-
nected from the air-filter/lubricator.
Cleaning filter
2
:
●
Unscrew water bowl
1
.
●
Take out filter
2
.
●
Clean filter
2
with compressed air or iso-
propyl alcohol (part No. 95-665 735-91).
●
Screw in filter
2
and screw on water
bowl
1
.
Fig. 12 - 05
2
1
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
A
1
2
Содержание 3801-11/071
Страница 19: ...Controls 7 4 7 07 Reverse feed control lever To sew condensed stitches press lever 1 down Fig 7 08 1 ...
Страница 122: ...15 3 Circuit diagrams Version 01 09 05 91 191 495 95 Page 1 ...
Страница 123: ...15 4 91 191 495 95 Page 2 Version 01 09 05 Circuit diagrams ...
Страница 124: ...15 5 Circuit diagrams Version 01 09 05 91 191 495 95 Page 3 ...
Страница 125: ...15 6 91 191 495 95 Page 4 Version 01 09 05 Circuit diagrams ...