Input
60
Group
Parameter
Description
User level
Setting range
Set value
6
651 Presser foot with automatic lowering if the
machine is at a standstill
ON = yes
OFF = no
B, C
ON -OFF
ON
660 Bobbin thread monitoring
0 = without (= *II*)
1 = via sensor (= **I*)
2 = via stitch counting
A,B,C
0 - 2
0
668 Thread wiper / thread blower
ON = yes
OFF = no
B,C
ON - OFF
ON
7
700 Needle position "0"
(reference position of
needle)
B,C
0 - 255
0
702 Needle position "1" (needle down)
B,C
0 - 255
80
703 Needle position "2" (thread lever up)
B,C
0 - 255
226
705 Needle position "5"
(Magnetic thread trimming / end of cutting
signal "1", start of cutting signal timing "1")
B,C
0 - 255
200
706 Needle position "6"
(Pneumatic thread trimming / start of cutting
signal "2")
B,C
0 - 255
80
707 Needle position "9"
(Start of thread tension release / start of
thread catcher)
B,C
0 -255
164
715 Extension time for blowing and suction
after the seam end
B,C
0 - 2000
90
718 Standstill brake timing
0 = brake off
B,C
0 - 100
0
719 Timing adjustment A4 (presser foot)
B,C
10 - 60
40
722 Acceleration ramp
1 = flat
50 = steep
B,C
1 - 60
50
723
Braking ramp
1 = flat
50 = steep
B,C
1 - 60
40
729
Start delay after lowering the presser foot [ms]
B,C
10 - 2000
150