Adjustment
95
12
.14.03
Test block 2 – outputs
The current output is displayed with the
+/- key B
.
Press the
+/- key B
to display the other outputs.
If the
+/- key D
is pressed, the output is switched on for
200 ms
●
●
●
12
.14.04
Test block 3 – Set value sender and actual value sender
SWG
-2
x IWG
All 16 switch positions can be called up by operating the pedal. If all positions from -2, -1,
0, 1, 1D to 12D appear on the display, the set value sender is in order.
The actual value can be checked by turning the balance wheel. If all increments from
0 - 255 appear on the display, the actual value sender is in order.
●
●
A 1
0 X5: 28
Set value sender
Output number
Connector
Output status
If the D+ key is pressed, the output is
switched on for 200 ms
Contact number
Pedal setting