Adjustment
91
Gr
oup
P
arameter
Description
User level
S
et
ting range
S
et value
7
761
Extension thread tension release / thread dra-
wing
B,C
0 - 80
0
770
Delay for raising pressure foot when pedal
set at "-1"
C
10 - 250
80
789
Needle position "10" (bearing position)
B,C
0 - 255
239
797
Hardware test
1 = on; 0 = off
C
0 - 1
0
798
User lever "C"
1 = on; 0 = off
B,C
0 - 1
0
799
Selected machine class
C
1
1
8
800
Motor rotation direction when looking at
V-belt pulley
1 = anti-clockwise; 0 = clockwise
C
0 - 1
0
801
Reversing angle at end of seam
B,C
10 - 212
16
880
Max. starting power [A]
C
1 - 30
10
884
Proportional sensitivity of the speed control
unit (general)
B,C
1 - 24
10
885
Integral sensitivity of the speed control unit
C
10 - 80
50
886
Proportional sensitivity of the positioner
C
1 - 15
8
887
Differential sensitivity of the positioner
C
1 - 15
8
889
Time for positioning action
0 = always
C
0 - 2500
400
890
Proportional sensitivity of the superset positi-
oner for stop brake
C
1 - 25
15
897
MINI-motor variant
1 = long; 0 = short
C
0 - 1
0
898
No existing comment
C
0
0
9
900
Additional P-sensitivity for speed control unit
B,C
1 -
24
12
901
Cutting release - speed
B,C
30 - 500
300
933
Switchover for display
1 = diagnosis; 0 = normal display
C
0 - 1
0
10
1000
Number of steppers
B,C
0 - 1
1
1001
Starting angle of stepper
B,C
0 - 255
110
1003
Feed roller radius
C
5 - 50
11