11 - 17
Adjustment
Fig. 11 - 15
2
3
0,3 mm
4
5
5
1
11
.05.04
Engaging solenoid
Requirement
In needle rise position and with engaging solenoid
5
activated, there must be a distance
of
0.3 mm
between engaging lever
2
and pawl
3
.
●
Bring the machine to needle rise position by turning the balance wheel.
●
Loosen screw
1
until the engaging solenoid can be turned with difficulty.
●
Manually activate engaging lever 2
2
2
2
2 so that pawl
3
engages.
●
Press solenoid planger
4
as far as possible into solenoid housing
5
and move both the
solenoid housing and the solenoid planger in accordance with the
requirement.
●
In this position tighten screw
1
.