24
Troubleshooting Guide
in
Parking and access control equipment manufactured in the UK
Automatic Sliding Gates
Notes Area
Gate not Moving
Motor brake locked on
Check brake is releasing
Gate creaking when moving
Gate alignment
Check and align gate correctly
Gate motor not running
Loss of voltage
Check motor supply test 3 phases
Gate not moving or closing
Drive shaft connections
Re-connect any drive shaft connections
Gate not moving or moving half way
Gearbox or gate track damaged
Gears/Track stripped due to overlading replace
Gate crashes into catch post
Cantilever arm not adjusted correctly
Adjust and check alignment
Gate not running at all
Door has been left open or switch not making
Close the door and check display is not reading
e.211
Gate open and will not close
Key switch is left in open position
Turn key switch to auto if fitted
Loop fault or loop detecting
Check if green light is on detector if so remove
object that it is detecting or replace loop
MECHANICAL ERRORS
CAUSE
CORRECTION
Содержание FF9000
Страница 14: ...Wiring Diagram in Parking and access control equipment manufactured in the UK Automatic Sliding Gates 14 ...
Страница 17: ...Wireless Encoder in Parking and access control equipment manufactured in the UK Automatic Sliding Gates 17 ...
Страница 18: ...18 Wireless Encoder in Parking and access control equipment manufactured in the UK Automatic Sliding Gates ...