TROUBLESHOOTING LOGIC DIAGRAM
Page: 21
Reproductions or translations, even parrtial, are forbidden without the written consent of Peugeot Motocycles
Incident: problems during the maintenance charge:
With or without the following fault codes: CHARGE TIME, MAINTENANCE CHARGE TIME, BAT
TEMPERATURE or BATTERY TEMP SENSOR
Voltage over 12V,
change the charger (see
workshop
documentation)
Voltage under 8 V apply
procedure:
charging after
prolonged immobilisation
(see appropriate chapter
Test
200 A
fuse
Check
220-230 V
mains and
charging
cable
Check
battery
voltage
YES
The charge and
maintenance lamps
flash
Charge between 10
and 15 hours
See next page
On the TEP 96, carry
out a keypad test
NO
CHOOSE A FUNCTION
⇓
Check for defects
♦
Activating tests
♦
States of scooter
TESTS SWITCHES :
⇓
Accelerator
♦
Keyboard
♦
Contact key
Change
keypad
Test
incorrect
1.
Disconnect the charging cable
2.
Test drive for 2 or 3 km to slightly discharge
the battery
3.
Repeat the procedure from the start
Test OK
NO
Charge lamp is on and
maintenance lamp flashes
Machine connected
to 220 V mains
YES
Press the “V” key
on the keypad for a
minimum of 2
seconds