28
Step 1
Step 2*
Unplug the
power from the
wall socket.
Remove 2 screws and
clips from bypass.
Disconnect the
meter cable from
the bypass.
Grey Meter Cable
60010267
Step 3
Remove Cover.
Step 4
Step 5
Step 6
Step 7
Disconnect
the cables
from the
front PCB
display.
Disconnect
the cables
from the rear
PCB display.
Remove
strain relief
with pliers.
Replace the
old cable
with the
new Cable.
60095101
Bypass comes with Meter
and Grey Meter Cable
*
NOTE
Water to the household
needs to be turned off
and pressure relieved
before Step 2
If replacing old impeller assembly to new version on Valves manufactured
before March 20th 2018, programming should be adjusted on the control
valve. Please see steps below:
To enter the programming press and hold the MENU button for 5 seconds to
unlock the screen.
Press and hold the Up and Down Arrows.
Press the down arrow to get to METER RATIO then press SET.
Press UP or Down Arrow to choose Turbine-H and press SET.
Set as per below:**
Step 8
Assemble the valve.
Plug the power
supply back into
the wall socket
and follow the
programming
shown on right:
Cut the tie
that fastens
the wires
Remove
the meter
cable
attached
on Main
PCB.
If valve is manufactured before March 20th, 2018, and customer wishes to replace or service impeller on bypass. Customer can order 60010238. If customer wishes
to replace to new design, then follow the steps below.
*Meter and Cable Ratio
Valve Model Region
Meter Ratio
OLD
NEW
75V Series
U.S Gallon
0.576
0.443
REPLACING THE BYPASS AND METER CABLE