Key Pad Configuration
MENU
This function is to enter the basic set up information required at the
time of installation.
SET
This function is to initiate an immediate or delayed manual
regeneration.
DOWN /
Increase or decrease the value of the settings while in the
UP
programming mode.
Date and Time
Hardness
Manual Regen.
Dealer Information
Main Menu
Regen. Now?
Regen. Tonight?
Press
To Cancel
Press
To Confirm
Backwashing ...
Any Key 3s To Next
13:59
89 Downflow
89 Upflow
Auto On
18%
Brine Drawing ...
Any Key 3s To Next
063:59
50%
Rinsing ...
Any Key 3s To Next
00:00
90%
Refilling ...
Any Key 3s To Next
00:00
98%
Refilling ...
Any Key 3s To Next
Regen. Now?
Regen. Tonight?
Press
To Cancel
Press
To Confirm
Brine Drawing ...
Any Key 3s To Next
103:59
68%
Backwashing ...
Any Key 3s To Next
13:59
88%
Rinsing ...
Any Key 3s To Next
12:09
90%
Refilling ...
Any Key 3s To Next
03:59
98%
Refilling ...
Any Key 3s To Next
Date and Tim
e
Hardness
Manual Regen.
Dealer Information
Main Menu
QUALITY WATER
666 3 AVE
CHIGAGO IL
TEL 12345678
Setting Complete
Press
To Return
Date and Time
Hardness
Manual Regen.
Dealer Information
Main Menu
= Date and Time =
17-Feb-2016, 12:25PM
Press
To Cancel
Press
To Confirm
Setting Complete
Press
To Return
Standby
interface
Auto On
Auto On
Auto On Dealer
information
input letter
by letter
STARTUP INSTRUCTIONS
(CONTINUED)
4. Manually Regenerate the Valve
(Continued)
6. Add Salt to
the Brine Tank/
Cabinet
Put 40 kgs of crystal water
softener salt in the brine tank.
The unit will automatically
fill the water to the correct level
when it regenerates.
Start up and
programming
complete. Unit is
now operational.
4a.
Open the inlet on the bypass valve slowly and allow water to enter the unit. (The outlet of the bypass should remain closed to prevent any fines or debris from entering the
plumbing system. Allow all air to escape from the unit before turning the water on fully then allow water to run until the drain water appears to be clear of any fines.
4b.
Plug in the valve. Allow the valve to continue its cycles until complete and back in service. Do not manually shorten this cycle as it is critical to have the valve go through all
cycles normally to purge all air from the control valve for the upflow injection system to work correctly.
4c.
The Valve is already programmed from factory. Please set up date and time of day and feedwater hardness as shown below:
NOTE** All units are factory programmed for the correct size and regeneration cycle, alteration should only be done by a factory
trained technician or after consultation with one of our technical representatives if you have any questions please call:
1-877-288-9888
5. Power and Program Valve
Initial Manual Regen by pressing
SET
button. When in backwash cycle, do not skip the cycle and let all air from the tank escape.
After backwash cycle, the valve will advance to brine draw which needs to be skipped by pressing
SET
button.
The valve will now advance to
RINSE CYCLE
which can be skipped. Then valve will advance to refill cycle which should not be skipped. This cycle will let the air our of ejector system
of the valve.