background image

+1 (800) 732-2677

How the System Works

A radio signal travels from the Fence Transmitter through a buried wire, marking the boundaries you wish to set for your dog. 

Your dog wears a Receiver Collar that detects the signal at the Static Correction Zone. As your dog approaches the Static 

Correction Zone, the receiver issues a warning tone and vibrates. If he proceeds further, he receives a safe but startling Static 

Correction. While harmless, the correction will persuade him to stay in the containment area you’ve established. Boundary 

Flags are a temporary visual aid for your pet; remove them after training. This PetSafe

®

 Stubborn Dog In-Ground Fence

 

system has been proven safe, comfortable, and effective for pets over 8 lb.

Key Definitions

Fence Transmitter:

 Transmits the radio signal through the Boundary Wire.

Pet Area:

 Area within the Warning Zone where your pet can roam freely.

Warning Zone:

 Outer edge of the Pet Area where your pet’s Receiver Collar begins to 

beep and vibrates for 2 seconds, warning him not to go into the Static Correction Zone.

Static Correction Zone:

 Zone beyond the Warning Zone where your pet’s Receiver 

Collar will emit a Static Correction, signaling him to return to the Pet Area.

Boundary Width:

 Combination of the Warning Zone and the Static Correction Zone.

Surge Protector:

 Installed with the Fence Transmitter to protect it from lightning 

strikes and power surges (USA and Canada only).

Receiver Collar:

 Receives the radio signal from the Boundary Wire.

Correction Level Button:

 Adjusts the level of Static Correction your pet receives in 

the Static Correction Zone.

Receiver Indicator Light:

 Indicates the level of correction at which the Receiver 

Collar is set. This light also serves as a low battery indicator.

Contact Points:

 Delivers the safe Static Correction when your pet moves into the 

Static Correction Zone.

Power Jack:

 Where the Power Adapter plugs into the Fence Transmitter.

Boundary Control Switch:

 Switch located on the 

Fence Transmitter to adjust according to the length of 

Boundary Wire used.

Boundary Wire Terminals:

 Where the Boundary Wires 

connect to the Fence Transmitter in order to complete a 

continuous loop.

Loop Indicator Light:

 Indicates that the Boundary Wire 

makes a complete loop, enabling the signal  

to be transmitted.

Boundary Width Control:

 Adjusts the width of the 

Warning and Static Correction Zones. 

Note: Adjusting 

the knob does not change the level of Static Correction 

on the Receiver Collar.

Correction 

Level 

Button

Contact Points

Washers

Receiver Collar

Boundary Control Switch

Boundary Wire

Terminals

Loop Indicator Light

Power Light

Power

Jack

Boundary Width

Control

Fence Transmitter

Pet

Area

Static Correction

 Zone

Static Correction

Zone

Surge

Protector

with Power

Adapter

Fence

Transmitter

Warning

 Zone

Warning

 Zone

Boundary

 Width

Содержание Stubborn Dog In-Ground Fence ZIG00-14658

Страница 1: ...Stubborn Dog In Ground Fence ZIG00 14658 Product Manual Please read this entire Product Manual before beginning...

Страница 2: ...e established boundary Not all pets can be trained to avoid crossing the boundary Therefore if you have reason to believe that your pet may pose a danger to others or harm himself if he is not kept fr...

Страница 3: ...ur pet may receive an unintended correction The Boundary Width of the system must be tested whenever an adjustment is made to the containment field to prevent unintended corrections to your pet If you...

Страница 4: ...Width and Test the Receiver Collar 15 Install the Boundary Wire 17 Place the Boundary Flags 18 Fit the Receiver Collar 19 Training Guide 20 Day 1 21 Days 2 thru 4 21 Days 5 thru 8 21 Days 9 thru 30 22...

Страница 5: ...ts Other Items You May Need Additional wire and flags Part PIG00 13769 Tape measure Small Phillips screwdriver Drill mounting hardware Shovel or lawn edger Pliers Wire stripping pliers Scissors Lighte...

Страница 6: ...ctor Installed with the Fence Transmitter to protect it from lightning strikes and power surges USA and Canada only Receiver Collar Receives the radio signal from the Boundary Wire Correction Level Bu...

Страница 7: ...consistency 1C To mount the Fence Transmitter screw the mounting bracket onto a stationary surface such as a wall and slide the Fence Transmitter onto the bracket Once you have mounted the Fence Tran...

Страница 8: ...pet we recommend setting a Boundary Width for the Warning and Static Correction Zones to approximately 12 20 feet 6 to 10 feet on each side of the wire Avoid making passageways too narrow for your pet...

Страница 9: ...5 feet Twist the wire from A back to the Fence Transmitter E B D C A 5 2H Sample 5 2H Lake Access Double Loop From the Fence Transmitter run the wire to A A to B make a U turn and go to C C to D D to...

Страница 10: ...ut The drill enables you to twist the wire quickly Twist the Boundary Wire 10 to 12 times per foot to cancel the signal Once you have completed your boundary layout insert the twisted wire into the tr...

Страница 11: ...nnect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardous surges Turn off power to outlet before you install or r...

Страница 12: ...nections will result in an increased risk of surge related damage 5 Determine the length of wire needed to pass from the Surge Protector to the Fence Transmitter Measure and cut 2 lengths of wire then...

Страница 13: ...Lights should come on If this does not happen see the Troubleshooting section Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder...

Страница 14: ...the Correction Level Button and release when the Receiver Indicator Light lights up 5E 3 The Receiver Indicator Light will emit a series of flashes representing the Static Correction Level 4 Increase...

Страница 15: ...ne if the collar is set at level 2 or above The Run Through Prevention sound is an intermittent tone Over Correction Protection In the unlikely event that your pet freezes in the Static Correction Zon...

Страница 16: ...warning tone you have identified the Boundary Width distance Static Correction Zone Two seconds after the warning tone the test light will begin to flash This flashing light can aid you in identifyin...

Страница 17: ...ce The Boundary Wire of the PetSafe Stubborn Dog In Ground Fence system can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as ne...

Страница 18: ...before burying 7C 7D Place the Boundary Flags The Boundary Flags are visual reminders for your pet of where the Warning Zone is located 1 Place the Test Light contacts on the contact points and hold t...

Страница 19: ...comfortable while they wear stainless steel contacts Some pets are sensitive to contact pressure You may find after some time that your pet is very tolerant of the collar If so you may relax some of t...

Страница 20: ...your pet Finish each training session on a positive note with lots of praise and play Remove the collar after each training session While your pet is still learning the boundary contain him by anothe...

Страница 21: ...around in curiosity flicking of the ears or scratching at the collar If he does not respond check the fit of the collar to make sure the contact points are making contact with his skin If the collar...

Страница 22: ...portant Remove the Receiver Collar and leave it at home Once your pet learns the boundary he will be reluctant to cross it for walks or car rides Option 1 Replace the Receiver Collar with a regular co...

Страница 23: ...to be held on top of the Boundary Wire perform the System Test The Receiver Collar activates inside the house Turn the Boundary Width Control knob counterclockwise to decrease the distance from the B...

Страница 24: ...m the System Test page 26 to determine if the Fence Transmitter or Surge Protector needs to be replaced If the Fence Transmitter is functioning properly you have a break in your Boundary Wire See the...

Страница 25: ...Turn the Boundary Width Control knob to 10 and repeat Step 7 The distance where the Receiver Collar activates should be greater than the previous result 9 If more than one Receiver Collar is used on t...

Страница 26: ...ns 2 Where the wires cross sidewalks or driveways due to edging and string trimmers 3 Around landscaping and flower beds due to digging or working up the soil 4 At wire splices where Gel filled capsul...

Страница 27: ...t shall Radio Systems Corporation or any of its associated companies be liable for i any direct indirect punitive incidental special or consequential damage and or ii any loss or damages whatsoever ar...

Страница 28: ...ect the interference by one or more of the following measures Relocate the interfered receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet...

Страница 29: ...ranty should be made directly to Radio Systems Australia Pty Ltd Customer Care Centre at Radio Systems Australia Pty Ltd PO Box 3442 Australia Fair QLD 4215 Australia Australia Residents 1800 786 608...

Страница 30: ...30 1 800 732 2677 Layout Grid...

Страница 31: ...petsafe com 31 Layout Grid...

Страница 32: ...Radio Systems Corporation 10427 PetSafe Way Knoxville TN 37932 1 800 732 2677 petsafe com YU400 1783 2 2020 Radio Systems Corporation 3 000 in 7 62 cm Drill Here Drill Here 3 in Mounting Template...

Отзывы: