Fit the Receiver Collar 

Important: The proper fit and placement of your Receiver Collar is important for effective training. The Contact 

Points must have direct contact with your pet’s skin on the underside of his neck.

Please read and follow the instructions in this manual. Proper fit of the collar is important. A collar worn for 

too long or made too tight on the pet’s neck may cause skin damage. Ranging from redness to pressure 

ulcers; this condition is commonly known as bed sores.
•  Avoid leaving the collar on the dog for more than 12 hours per day.
•  When possible reposition the collar on the pet’s neck every 1 to 2 hours.
•  Check the fit to prevent excessive pressure; follow the instructions in this manual.
•  Never connect a lead to the electronic collar; it will cause excessive pressure on the contacts.
•  When using a separate collar for a lead, don’t put pressure on the electronic collar.
•  Wash the dog’s neck area and the contacts of the collar weekly with a damp cloth.
•  Examine the contact area daily for signs of a rash or a sore.
•  If a rash or sore is found, discontinue use of the collar until the skin has healed.
•  If the condition persists beyond 48 hours, see your veterinarian.
•  For additional information on bed sores and pressure necrosis, please visit our website. These steps will 

help keep your pet comfortable and secure. Millions of pets are comfortable while they wear stainless 

steel contacts. Some pets are sensitive to contact pressure. You may find after some time that your pet is 

very tolerant of the collar. If so, you may relax some of these precautions. It is important to continue daily 

checks of the contact area. If redness or sores are found, discontinue use until the skin has fully healed. 

You may need to trim the hair in the area of the Contact Points. Never shave the dog’s neck; this may lead 

to a rash or infection.

To assure a proper fit, please follow these steps:
1.  Make sure that the battery is not installed in the Receiver Collar. 
2.  Start with your pet standing comfortably (

9A

).

3.  Place the Receiver Collar on your pet so that the “PetSafe

®

” logo is facing your pet’s 

chin. Center the Contact Points underneath your pet’s neck, touching the skin.

4.  The Receiver Collar should fit snugly, yet loose enough to allow one finger to fit between a 

contact point and your pet’s neck (

9B

). Allow your pet to wear the collar for several minutes 

then recheck the fit. Check the fit again as your pet becomes more comfortable with  

the Receiver Collar.

9A

5.  Once you are satisfied with the fit of the Receiver Collar then you may 

trim any excess collar strap as follows (

9C

):

a.  Mark the desired length of the Receiver Collar with a pen. Allow for 

growth if your pet is young or grows a thick winter coat.

b.  Remove the Receiver Collar from your pet and cut off the excess.
c.  Before placing the Receiver Collar back onto your pet, seal the edge  

of the cut collar by applying a flame along the frayed edge.

9B

9C

Step 

9

Содержание Stubborn Dog In-Ground Fence ZIG00-14658

Страница 1: ...Stubborn Dog In Ground Fence ZIG00 14658 Product Manual Please read this entire Product Manual before beginning...

Страница 2: ...e established boundary Not all pets can be trained to avoid crossing the boundary Therefore if you have reason to believe that your pet may pose a danger to others or harm himself if he is not kept fr...

Страница 3: ...ur pet may receive an unintended correction The Boundary Width of the system must be tested whenever an adjustment is made to the containment field to prevent unintended corrections to your pet If you...

Страница 4: ...Width and Test the Receiver Collar 15 Install the Boundary Wire 17 Place the Boundary Flags 18 Fit the Receiver Collar 19 Training Guide 20 Day 1 21 Days 2 thru 4 21 Days 5 thru 8 21 Days 9 thru 30 22...

Страница 5: ...ts Other Items You May Need Additional wire and flags Part PIG00 13769 Tape measure Small Phillips screwdriver Drill mounting hardware Shovel or lawn edger Pliers Wire stripping pliers Scissors Lighte...

Страница 6: ...ctor Installed with the Fence Transmitter to protect it from lightning strikes and power surges USA and Canada only Receiver Collar Receives the radio signal from the Boundary Wire Correction Level Bu...

Страница 7: ...consistency 1C To mount the Fence Transmitter screw the mounting bracket onto a stationary surface such as a wall and slide the Fence Transmitter onto the bracket Once you have mounted the Fence Tran...

Страница 8: ...pet we recommend setting a Boundary Width for the Warning and Static Correction Zones to approximately 12 20 feet 6 to 10 feet on each side of the wire Avoid making passageways too narrow for your pet...

Страница 9: ...5 feet Twist the wire from A back to the Fence Transmitter E B D C A 5 2H Sample 5 2H Lake Access Double Loop From the Fence Transmitter run the wire to A A to B make a U turn and go to C C to D D to...

Страница 10: ...ut The drill enables you to twist the wire quickly Twist the Boundary Wire 10 to 12 times per foot to cancel the signal Once you have completed your boundary layout insert the twisted wire into the tr...

Страница 11: ...nnect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardous surges Turn off power to outlet before you install or r...

Страница 12: ...nections will result in an increased risk of surge related damage 5 Determine the length of wire needed to pass from the Surge Protector to the Fence Transmitter Measure and cut 2 lengths of wire then...

Страница 13: ...Lights should come on If this does not happen see the Troubleshooting section Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder...

Страница 14: ...the Correction Level Button and release when the Receiver Indicator Light lights up 5E 3 The Receiver Indicator Light will emit a series of flashes representing the Static Correction Level 4 Increase...

Страница 15: ...ne if the collar is set at level 2 or above The Run Through Prevention sound is an intermittent tone Over Correction Protection In the unlikely event that your pet freezes in the Static Correction Zon...

Страница 16: ...warning tone you have identified the Boundary Width distance Static Correction Zone Two seconds after the warning tone the test light will begin to flash This flashing light can aid you in identifyin...

Страница 17: ...ce The Boundary Wire of the PetSafe Stubborn Dog In Ground Fence system can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as ne...

Страница 18: ...before burying 7C 7D Place the Boundary Flags The Boundary Flags are visual reminders for your pet of where the Warning Zone is located 1 Place the Test Light contacts on the contact points and hold t...

Страница 19: ...comfortable while they wear stainless steel contacts Some pets are sensitive to contact pressure You may find after some time that your pet is very tolerant of the collar If so you may relax some of t...

Страница 20: ...your pet Finish each training session on a positive note with lots of praise and play Remove the collar after each training session While your pet is still learning the boundary contain him by anothe...

Страница 21: ...around in curiosity flicking of the ears or scratching at the collar If he does not respond check the fit of the collar to make sure the contact points are making contact with his skin If the collar...

Страница 22: ...portant Remove the Receiver Collar and leave it at home Once your pet learns the boundary he will be reluctant to cross it for walks or car rides Option 1 Replace the Receiver Collar with a regular co...

Страница 23: ...to be held on top of the Boundary Wire perform the System Test The Receiver Collar activates inside the house Turn the Boundary Width Control knob counterclockwise to decrease the distance from the B...

Страница 24: ...m the System Test page 26 to determine if the Fence Transmitter or Surge Protector needs to be replaced If the Fence Transmitter is functioning properly you have a break in your Boundary Wire See the...

Страница 25: ...Turn the Boundary Width Control knob to 10 and repeat Step 7 The distance where the Receiver Collar activates should be greater than the previous result 9 If more than one Receiver Collar is used on t...

Страница 26: ...ns 2 Where the wires cross sidewalks or driveways due to edging and string trimmers 3 Around landscaping and flower beds due to digging or working up the soil 4 At wire splices where Gel filled capsul...

Страница 27: ...t shall Radio Systems Corporation or any of its associated companies be liable for i any direct indirect punitive incidental special or consequential damage and or ii any loss or damages whatsoever ar...

Страница 28: ...ect the interference by one or more of the following measures Relocate the interfered receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet...

Страница 29: ...ranty should be made directly to Radio Systems Australia Pty Ltd Customer Care Centre at Radio Systems Australia Pty Ltd PO Box 3442 Australia Fair QLD 4215 Australia Australia Residents 1800 786 608...

Страница 30: ...30 1 800 732 2677 Layout Grid...

Страница 31: ...petsafe com 31 Layout Grid...

Страница 32: ...Radio Systems Corporation 10427 PetSafe Way Knoxville TN 37932 1 800 732 2677 petsafe com YU400 1783 2 2020 Radio Systems Corporation 3 000 in 7 62 cm Drill Here Drill Here 3 in Mounting Template...