background image

24 

+1 (800) 732-2677

 

petsafe.com 25 

System Test

The system test is used to determine the cause of system problems that have not been addressed elsewhere in this guide. 

You will need a piece of Boundary Wire greater than 15 feet long with 

3

8

 inch of insulation removed from each end to use as 

a test loop wire. Make a note of your Boundary Control Switch setting, Boundary Width Control knob setting, and Receiver 

Collar setting before beginning the System Test. Follow the steps below to perform the system test:

1.  Remove the Receiver Collar from your dog and make sure a good battery is 

installed in the receiver.

2.  Set the Boundary Control switch to B.
3.  Set the Receiver Collar Static Correction Level to 5.
4.  Disconnect the twisted Boundary Wire from the Boundary Wire terminals on 

the Fence Transmitter by pressing the red release levers on the connector and 

pulling the wires free (

11A

).

5.  Insert the two ends of the test loop wire into the Boundary Wire Terminals  

on the Transmitter.

6.  Turn the Boundary Width control knob to 10 and then back to 5.
7.  Place the Test Light Tool Contacts on the Contact Points of the Receiver Collar. 

While holding the Receiver Collar with the Test Light Tool in place, approach 

the wire from the outside loop 2 inches off the ground. Make a mental note of 

the distance where the Receiver Collar activates from the wire.

8.  Turn the Boundary Width Control knob to 10 and repeat Step 7. The distance 

where the Receiver Collar activates should be greater than the previous result.

9.  If more than one Receiver Collar is used on the system, repeat the above  

test on each collar.

10. Keep Boundary Width Control Knob position at 10. Set the Boundary Control 

Switch to A. Approach loop with Receiver Collar as in Step 7 and verify the 

Receiver Collar activates.

11. Keep Boundary Width Control knob position at 10. Set the Boundary Control 

Switch to C. Approach loop with Receiver Collar as in Step 7 and verify the 

Receiver Collar activates.

12. Interpreting the Results:

a.  If the Power light or the Loop indicator light are not both lit on the Fence 

Transmitter, or the alarm is on, for any of the above tests, there is a problem 

with the Transmitter. Contact the Customer Care Center.

b.  If both the Power and Loop indicator lights are on, but the Receiver Collar  

does not activate on the test loop wire, the Receiver Collar is not working. 

Contact the Customer Care Center.

c.  If the Transmitter Power and Loop indicator lights are on in each of the 3 

Boundary Control Switch positions and the Receiver Collar is activating at 

different distances on the test loop wire, the problem is most likely in the 

containment Boundary Wire or Surge Protector. Reconnect the Transmitter 

wires to the Surge Protector and connect the Test Loop to the Surge 

Protector loop terminals. Repeat steps (6-11) (

11B

).

11A

11B

System Test 

Surge Protector 

Unconnected

System Test 

Surge Protector 

Connected

Содержание Stubborn Dog In-Ground Fence ZIG00-14658

Страница 1: ...Stubborn Dog In Ground Fence ZIG00 14658 Product Manual Please read this entire Product Manual before beginning...

Страница 2: ...e established boundary Not all pets can be trained to avoid crossing the boundary Therefore if you have reason to believe that your pet may pose a danger to others or harm himself if he is not kept fr...

Страница 3: ...ur pet may receive an unintended correction The Boundary Width of the system must be tested whenever an adjustment is made to the containment field to prevent unintended corrections to your pet If you...

Страница 4: ...Width and Test the Receiver Collar 15 Install the Boundary Wire 17 Place the Boundary Flags 18 Fit the Receiver Collar 19 Training Guide 20 Day 1 21 Days 2 thru 4 21 Days 5 thru 8 21 Days 9 thru 30 22...

Страница 5: ...ts Other Items You May Need Additional wire and flags Part PIG00 13769 Tape measure Small Phillips screwdriver Drill mounting hardware Shovel or lawn edger Pliers Wire stripping pliers Scissors Lighte...

Страница 6: ...ctor Installed with the Fence Transmitter to protect it from lightning strikes and power surges USA and Canada only Receiver Collar Receives the radio signal from the Boundary Wire Correction Level Bu...

Страница 7: ...consistency 1C To mount the Fence Transmitter screw the mounting bracket onto a stationary surface such as a wall and slide the Fence Transmitter onto the bracket Once you have mounted the Fence Tran...

Страница 8: ...pet we recommend setting a Boundary Width for the Warning and Static Correction Zones to approximately 12 20 feet 6 to 10 feet on each side of the wire Avoid making passageways too narrow for your pet...

Страница 9: ...5 feet Twist the wire from A back to the Fence Transmitter E B D C A 5 2H Sample 5 2H Lake Access Double Loop From the Fence Transmitter run the wire to A A to B make a U turn and go to C C to D D to...

Страница 10: ...ut The drill enables you to twist the wire quickly Twist the Boundary Wire 10 to 12 times per foot to cancel the signal Once you have completed your boundary layout insert the twisted wire into the tr...

Страница 11: ...nnect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardous surges Turn off power to outlet before you install or r...

Страница 12: ...nections will result in an increased risk of surge related damage 5 Determine the length of wire needed to pass from the Surge Protector to the Fence Transmitter Measure and cut 2 lengths of wire then...

Страница 13: ...Lights should come on If this does not happen see the Troubleshooting section Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder...

Страница 14: ...the Correction Level Button and release when the Receiver Indicator Light lights up 5E 3 The Receiver Indicator Light will emit a series of flashes representing the Static Correction Level 4 Increase...

Страница 15: ...ne if the collar is set at level 2 or above The Run Through Prevention sound is an intermittent tone Over Correction Protection In the unlikely event that your pet freezes in the Static Correction Zon...

Страница 16: ...warning tone you have identified the Boundary Width distance Static Correction Zone Two seconds after the warning tone the test light will begin to flash This flashing light can aid you in identifyin...

Страница 17: ...ce The Boundary Wire of the PetSafe Stubborn Dog In Ground Fence system can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as ne...

Страница 18: ...before burying 7C 7D Place the Boundary Flags The Boundary Flags are visual reminders for your pet of where the Warning Zone is located 1 Place the Test Light contacts on the contact points and hold t...

Страница 19: ...comfortable while they wear stainless steel contacts Some pets are sensitive to contact pressure You may find after some time that your pet is very tolerant of the collar If so you may relax some of t...

Страница 20: ...your pet Finish each training session on a positive note with lots of praise and play Remove the collar after each training session While your pet is still learning the boundary contain him by anothe...

Страница 21: ...around in curiosity flicking of the ears or scratching at the collar If he does not respond check the fit of the collar to make sure the contact points are making contact with his skin If the collar...

Страница 22: ...portant Remove the Receiver Collar and leave it at home Once your pet learns the boundary he will be reluctant to cross it for walks or car rides Option 1 Replace the Receiver Collar with a regular co...

Страница 23: ...to be held on top of the Boundary Wire perform the System Test The Receiver Collar activates inside the house Turn the Boundary Width Control knob counterclockwise to decrease the distance from the B...

Страница 24: ...m the System Test page 26 to determine if the Fence Transmitter or Surge Protector needs to be replaced If the Fence Transmitter is functioning properly you have a break in your Boundary Wire See the...

Страница 25: ...Turn the Boundary Width Control knob to 10 and repeat Step 7 The distance where the Receiver Collar activates should be greater than the previous result 9 If more than one Receiver Collar is used on t...

Страница 26: ...ns 2 Where the wires cross sidewalks or driveways due to edging and string trimmers 3 Around landscaping and flower beds due to digging or working up the soil 4 At wire splices where Gel filled capsul...

Страница 27: ...t shall Radio Systems Corporation or any of its associated companies be liable for i any direct indirect punitive incidental special or consequential damage and or ii any loss or damages whatsoever ar...

Страница 28: ...ect the interference by one or more of the following measures Relocate the interfered receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet...

Страница 29: ...ranty should be made directly to Radio Systems Australia Pty Ltd Customer Care Centre at Radio Systems Australia Pty Ltd PO Box 3442 Australia Fair QLD 4215 Australia Australia Residents 1800 786 608...

Страница 30: ...30 1 800 732 2677 Layout Grid...

Страница 31: ...petsafe com 31 Layout Grid...

Страница 32: ...Radio Systems Corporation 10427 PetSafe Way Knoxville TN 37932 1 800 732 2677 petsafe com YU400 1783 2 2020 Radio Systems Corporation 3 000 in 7 62 cm Drill Here Drill Here 3 in Mounting Template...

Отзывы: