Petsafe PRF-3004W-20 Скачать руководство пользователя страница 6

www.petsafe.net

How the System Works

A radio signal travels from the Fence Transmitter through a buried wire, marking the boundaries you wish to set for your 
dog. Your dog wears a Receiver Collar that detects the signal at the boundary. As your dog approaches the boundary, the 
receiver issues a warning tone. If he proceeds further, he receives a safe but startling Static Correction. While harmless, the 
correction will persuade him to stay in the containment area you’ve established. Boundary fl ags are a temporary visual aid 
for your pet; remove them after training. This PetSafe

®

 In-Ground Fence

 has been proven safe, comfortable, and effective 

for pets over 3.6 kg (8 lbs).

Key Definitions

Fence Transmitter:

 Transmits the radio signal through the Boundary Wire.

Pet Area:

 Area within the Warning Zone where your pet can roam freely.

Warning Zone:

 Outer edge of the Pet Area where your pet’s Receiver Collar begins to beep, warning him not to go into the 

Static Correction Zone.

Static Correction Zone:

 Zone beyond the Warning Zone where your pet’s Receiver Collar will emit a Static Correction, 

signaling him to return to the Pet Area.

Boundary Width: 

Combination of the Warning Zone and the Static Correction Zone.

Receiver Collar: 

Receives the radio signal from the Boundary Wire.

Contact Points:

 Delivers the safe Static Correction when your pet moves into the Static Correction Zone.

Power Jack:

 Where the Power Adapter plugs into the Fence Transmitter. The Fence Transmitter is powered by a 

standard outlet.

Boundary Control Switch:

 Switch located on the Fence Transmitter to adjust according to the length of Boundary Wire used.

Boundary Wire Terminals:

 Where the Boundary Wires connect to the Fence Transmitter in order to complete a 

continuous loop.

Loop Indicator Light:

 Indicates that the Boundary Wire makes a complete loop, enabling the signal to be transmitted.

Boundary Width  Control:

 Adjusts the width of the Warning and Static Correction Zones. 

Note: Adjusting the knob does not 

change the level of Static Correction on the Receiver Collar.

Pet Area

Static Correction

 Zone

Static Correction

 Zone

Fence

Transmitter

Warning

 Zone

Warning

 Zone

Boundary

 Width

}

Boundary Width 
Control

Power Light

Loop Indicator Light

Boundary Wire 
Terminals

Boundary 
Control 
Switch

Power
Jack

Fence Transmitter

BATTER

Y 6V

RFA-67

Battery

Contact Points

Washers

Receiver Collar

Содержание PRF-3004W-20

Страница 1: ...stema antifuga con filo R ckhaltesysteme mit Draht Nedgravet hegnsystem Please read this entire guide before beginning Veuillez lire ce manuel en entier avant de commencer Gelieve deze gids volledig d...

Страница 2: ...ire In most areas this is a free service Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardo...

Страница 3: ...iscontinue use until the skin has fully healed You may need to trim the hair in the area of the Contact Probes Never shave the dog s neck this may lead to a rash or infection You should not make the c...

Страница 4: ...________________________ Table of Contents Components 5 Other ItemsYou May Need 5 How the System Works 6 Key De nitions 6 Operating Guide Install the Fence Transmitter 7 Lay Out the System 7 Sample La...

Страница 5: ...and ags Part PRFA 500 T ape measure Small Phillips screwdriver Drill mounting hardware Shovel or lawn edger Pliers Wire stripping pliers Scissors Lighter Gel lled Capsules Additional wire nuts W ater...

Страница 6: ...c Correction signaling him to return to the Pet Area Boundary Width Combination of the Warning Zone and the Static Correction Zone Receiver Collar Receives the radio signal from the Boundary Wire Cont...

Страница 7: ...e the Fence Transmitter indoors in a dry location only 1A 1B 1 m 3ft 1C __________________________________________________ Lay Out the System WARNING Underground cables can carry high voltage Have all...

Страница 8: ...eed to be buried From the Fence Transmitter run the wire to A A to B B to C C to D D to E E to A twist the wires from A back to the Fence Transmitter See the Install the BoundaryWire section for more...

Страница 9: ...nded that you cut and splice the BoundaryWire between each twisted section The signal cannot be cancelled by running the wire through plastic or metal piping Splicing shielded cable to the BoundaryWir...

Страница 10: ...rning Zone at the maximum width 5 Plug the Power Adapter into the Power Socket and a working outlet The Power Adapter comes with the North American plug installed and additional plugs for the UK Europ...

Страница 11: ...ow often your pet tests the system and receives a Static Correction Check the Receiver Collar every month to ensure the battery is working properly A replacement PetSafe battery RFA 67D 11 can be foun...

Страница 12: ...Correction The numbers on the BoundaryWidth Control knob indicate signal strength and are not representative of BoundaryWidth footage If adjusting the Boundary Width Control knob does not give the des...

Страница 13: ...can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as needed However make sure the BoundaryWidth is set at a high enough range f...

Страница 14: ...raining The Contact Points must have direct contact with your pet s skin on the underside of his neck CAUTION Please read and follow the instructions in this manual Proper fit of the collar is importa...

Страница 15: ...ed for good contact A collar that is too tight will increase the risk of pressure necrosis in the contact area 5 Allow your pet to wear the collar for several minutes then recheck the fit Check the fi...

Страница 16: ...aining session Be sure to contain your pet by another means during the training period e g pen tie out lead etc During training if you need to take your pet out of the Pet Area remove the Receiver Col...

Страница 17: ...to the Boundary Flags and if he decides to not move past the ags he is learning the system 11A __________________________________________________ Days 5 thru 8 Distraction Phase Perform three training...

Страница 18: ...training is complete remove every other Boundary Flag every 4 days until all ags are removed Save Boundary Flags for future use __________________________________________________ Taking Your Pet Out...

Страница 19: ...A to one half turn beyond finger tight Check the tightness weekly To Insert and Remove the Battery Please see Step 5 of this manual A To Set the Static Correction Level Read all steps before attempti...

Страница 20: ...rrection Level 1 Remove the clear plastic cover with the edge of the Test Light Tool to expose the Correction Level Button D B C 2 With the battery installed press the Correction Level Button and rele...

Страница 21: ...ction is produced by the Contact Points on the Receiver Collar not the Boundary Wire With proper use the system is safe for all I have a small pet and a large pet will this work for me Yes Since the P...

Страница 22: ...smit through the walls of your house Make sure BoundaryWires are twisted from Boundary to the FenceTransmitter I have an inconsistent signal Make sure Fence Transmitter is at least 1 m 3 ft from large...

Страница 23: ...iver Collar does not beep and the Test Light does not ash replace the battery in the Receiver Collar If it still does not beep and the Test Light does not ash contact the Customer Care Centre 11 If th...

Страница 24: ...duct they shall be binding on you as if incorporated herein ___________________________________________ Compliance This equipment has been tested and found to comply with the EU R TTE Directive Before...

Страница 25: ...ther patents pending 400 1194 00 1 2010 Radio Systems Corporation Layout Grid Sch ma d installation Ontwerpraster Cuadr cula de distribuci n Plantilla de montaje Plantilla de montaje Udl gningsnet 7 6...

Отзывы: