Petsafe PRF-3004W-20 Скачать руководство пользователя страница 3

 

www.petsafe.net

 3 

CAUTION

• Please read and follow the instructions in this manual. Proper fit of the collar is important.  A collar 

worn for too long or made too tight on the pet’s neck may cause skin damage. This is called bed 
sores; it is also called decubitus ulcers or pressure necrosis. 

• Avoid leaving the collar on the dog for more than 12 hours per day.

• When possible reposition the collar on the pet’s neck every 1 to 2 hours.

• Check the fit to prevent excessive pressure; follow the instructions in this manual.

• Never connect a lead to the electronic collar; it will cause excessive pressure on the contacts.

• When using a separate collar for a lead, don’t put pressure on the electronic collar.

• Wash the dog’s neck area and the contacts of the collar weekly with a damp cloth.

• Examine the contact area daily for signs of a rash or a sore.

• If a rash or sore is found, discontinue use of the collar until the skin has healed.

• If the condition persists beyond 48 hours, see your veterinarian.

For additional information on bed sores and pressure necrosis, please visit our website.

These steps will help keep your pet safe and comfortable. Millions of pets are comfortable while 
they wear stainless steel contacts. Some pets are sensitive to contact pressure. You may find 
after some time that your pet is very tolerant of the collar. If so, you may relax some of these 
precautions.  It is important to continue daily checks of the contact area. If redness or sores are 
found, discontinue use until the skin has fully healed.

• You may need to trim the hair in the area of the Contact Probes.  Never shave the dog’s neck; this 

may lead to a rash or infection.

• You should not make the collar any tighter than is required for good contact.  A collar that is too 

tight will increase the risk of pressure necrosis in the contact area.

• Proper training of your pet is essential to the success of the Petsafe

®

 In-Ground Fence

. During the 

first 2 weeks of training, do not use the training device on your pet without direct supervision.

• To prevent an unintended correction:

- The receiver collar should not be on your dog when the system is tested. 

- Remove the receiver collar before making any changes to your system. 

- Before placing the receiver collar on your pet, test the boundary location and width after 

any change. 

• If possible, do not use an outlet protected with a residual current device (RCD) or ground fault 

circuit interrupter (GFCI). The fence system will function properly, but in rare cases, nearby 
lightning strikes may cause the RCD or GFCI to trip. Without power, your pet may be vulnerable to 
excape. You will have to reset the RCD or GFCI to restore power to the system.

NOTICE

• Avoid damage to the insulation of the loop wire during the install; damage may cause areas of weak 

signal and lead to early failure of the loop (wire breaks).

• Use care when mowing or trimming your grass not to cut the loop wire.
• For added protection for the Fence Transmitter when unused for long periods of time or prior to 

thunderstorms, disconnect the Loop Boundary Wires and unplug the Power Adapter from the outlet. 
This will prevent damage to the Transmitter due to surges.

Содержание PRF-3004W-20

Страница 1: ...stema antifuga con filo R ckhaltesysteme mit Draht Nedgravet hegnsystem Please read this entire guide before beginning Veuillez lire ce manuel en entier avant de commencer Gelieve deze gids volledig d...

Страница 2: ...ire In most areas this is a free service Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardo...

Страница 3: ...iscontinue use until the skin has fully healed You may need to trim the hair in the area of the Contact Probes Never shave the dog s neck this may lead to a rash or infection You should not make the c...

Страница 4: ...________________________ Table of Contents Components 5 Other ItemsYou May Need 5 How the System Works 6 Key De nitions 6 Operating Guide Install the Fence Transmitter 7 Lay Out the System 7 Sample La...

Страница 5: ...and ags Part PRFA 500 T ape measure Small Phillips screwdriver Drill mounting hardware Shovel or lawn edger Pliers Wire stripping pliers Scissors Lighter Gel lled Capsules Additional wire nuts W ater...

Страница 6: ...c Correction signaling him to return to the Pet Area Boundary Width Combination of the Warning Zone and the Static Correction Zone Receiver Collar Receives the radio signal from the Boundary Wire Cont...

Страница 7: ...e the Fence Transmitter indoors in a dry location only 1A 1B 1 m 3ft 1C __________________________________________________ Lay Out the System WARNING Underground cables can carry high voltage Have all...

Страница 8: ...eed to be buried From the Fence Transmitter run the wire to A A to B B to C C to D D to E E to A twist the wires from A back to the Fence Transmitter See the Install the BoundaryWire section for more...

Страница 9: ...nded that you cut and splice the BoundaryWire between each twisted section The signal cannot be cancelled by running the wire through plastic or metal piping Splicing shielded cable to the BoundaryWir...

Страница 10: ...rning Zone at the maximum width 5 Plug the Power Adapter into the Power Socket and a working outlet The Power Adapter comes with the North American plug installed and additional plugs for the UK Europ...

Страница 11: ...ow often your pet tests the system and receives a Static Correction Check the Receiver Collar every month to ensure the battery is working properly A replacement PetSafe battery RFA 67D 11 can be foun...

Страница 12: ...Correction The numbers on the BoundaryWidth Control knob indicate signal strength and are not representative of BoundaryWidth footage If adjusting the Boundary Width Control knob does not give the des...

Страница 13: ...can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as needed However make sure the BoundaryWidth is set at a high enough range f...

Страница 14: ...raining The Contact Points must have direct contact with your pet s skin on the underside of his neck CAUTION Please read and follow the instructions in this manual Proper fit of the collar is importa...

Страница 15: ...ed for good contact A collar that is too tight will increase the risk of pressure necrosis in the contact area 5 Allow your pet to wear the collar for several minutes then recheck the fit Check the fi...

Страница 16: ...aining session Be sure to contain your pet by another means during the training period e g pen tie out lead etc During training if you need to take your pet out of the Pet Area remove the Receiver Col...

Страница 17: ...to the Boundary Flags and if he decides to not move past the ags he is learning the system 11A __________________________________________________ Days 5 thru 8 Distraction Phase Perform three training...

Страница 18: ...training is complete remove every other Boundary Flag every 4 days until all ags are removed Save Boundary Flags for future use __________________________________________________ Taking Your Pet Out...

Страница 19: ...A to one half turn beyond finger tight Check the tightness weekly To Insert and Remove the Battery Please see Step 5 of this manual A To Set the Static Correction Level Read all steps before attempti...

Страница 20: ...rrection Level 1 Remove the clear plastic cover with the edge of the Test Light Tool to expose the Correction Level Button D B C 2 With the battery installed press the Correction Level Button and rele...

Страница 21: ...ction is produced by the Contact Points on the Receiver Collar not the Boundary Wire With proper use the system is safe for all I have a small pet and a large pet will this work for me Yes Since the P...

Страница 22: ...smit through the walls of your house Make sure BoundaryWires are twisted from Boundary to the FenceTransmitter I have an inconsistent signal Make sure Fence Transmitter is at least 1 m 3 ft from large...

Страница 23: ...iver Collar does not beep and the Test Light does not ash replace the battery in the Receiver Collar If it still does not beep and the Test Light does not ash contact the Customer Care Centre 11 If th...

Страница 24: ...duct they shall be binding on you as if incorporated herein ___________________________________________ Compliance This equipment has been tested and found to comply with the EU R TTE Directive Before...

Страница 25: ...ther patents pending 400 1194 00 1 2010 Radio Systems Corporation Layout Grid Sch ma d installation Ontwerpraster Cuadr cula de distribuci n Plantilla de montaje Plantilla de montaje Udl gningsnet 7 6...

Отзывы: