Petsafe PRF-3004W-20 Скачать руководство пользователя страница 17

 

www.petsafe.net

 17 

Phase

2

Phase

3

Days 3 and 4 - Continue Boundary Flag Awareness

Perform three training sessions per day, each lasting 10-15 minutes.

Goal:

To introduce your pet to the Static Correction and teach where it happens.

Setup:

• Place the Receiver Collar on your pet’s neck.
• Put a separate non-metallic collar on your pet’s neck ABOVE the Receiver Collar and attach a lead. 

CAUTION

 Be sure the extra collar does not put pressure on the Contact Points.

• Have tiny pieces of treats that your pet will fi nd desirable available.
• Have your pet’s favourite play toy available.

Steps:

1. Walk your pet on a lead in the Pet Area. Calmly praise and talk to your pet, 

occasionally giving him treats.

2. Allow your pet to move toward the Boundary Flags.
3. When your pet enters the Warning Zone, the Receiver Collar will activate and 

start beeping. As your pet continues past the fl ags into the Static Correction Zone 
(

11A

), he will receive a Static Correction.

4. Immediately after your pet receives a correction, lead him back into the Pet Area. 

Praise him warmly, keep very calm body language, and offer him a treat.

5. Repeat this process at the same Boundary Flag until your pet resists going into 

the static correction zone. Never pull or call your pet into the Static Correction 
Zone. Lead him to the Boundary Flags, and if he decides to not move past the 
fl ags, he is learning the system.

11A

__________________________________________________

Days 5 thru 8 - Distraction Phase

Perform three training sessions per day, each lasting 10 to 15 minutes.

Goal:

To train your pet to stay within the Pet Area with distractions outside of the Pet Area.

Setup:

• Put a separate non-metallic collar on your pet’s neck ABOVE the Receiver Collar and attach a lead. 

CAUTION

 Be sure the extra collar does not put pressure on the Contact Points.

• Have tiny pieces of treats available.
• Have your pet’s favourite play toy available.
• Create distractions to tempt your pet to enter the Warning and Static Correction Zones, such as:
  - Have a family member cross from inside the Pet Area to outside of it.
  - Throw a ball or treat outside of the Pet Area.
  - Have a neighbour walk their pet outside of the Pet Area.
• Gradually increase distraction level. 

Never coax or call your pet out of the Pet Area.

Steps:

1. With full control of your pet on a lead, have the distraction presented. 
2. If your pet does not move toward the distraction, praise and offer a treat. 
3. If your pet does react to the distraction, allow him to go into the Static Correction Zone. 
4. Help your pet back into the Pet Area if he does not turn back after 3 seconds. 
5. Treat and praise your pet anytime he comes back into the Pet Area with or without help.
6. Repeat this process with other distractions. Use other family members during this process.

Содержание PRF-3004W-20

Страница 1: ...stema antifuga con filo R ckhaltesysteme mit Draht Nedgravet hegnsystem Please read this entire guide before beginning Veuillez lire ce manuel en entier avant de commencer Gelieve deze gids volledig d...

Страница 2: ...ire In most areas this is a free service Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardo...

Страница 3: ...iscontinue use until the skin has fully healed You may need to trim the hair in the area of the Contact Probes Never shave the dog s neck this may lead to a rash or infection You should not make the c...

Страница 4: ...________________________ Table of Contents Components 5 Other ItemsYou May Need 5 How the System Works 6 Key De nitions 6 Operating Guide Install the Fence Transmitter 7 Lay Out the System 7 Sample La...

Страница 5: ...and ags Part PRFA 500 T ape measure Small Phillips screwdriver Drill mounting hardware Shovel or lawn edger Pliers Wire stripping pliers Scissors Lighter Gel lled Capsules Additional wire nuts W ater...

Страница 6: ...c Correction signaling him to return to the Pet Area Boundary Width Combination of the Warning Zone and the Static Correction Zone Receiver Collar Receives the radio signal from the Boundary Wire Cont...

Страница 7: ...e the Fence Transmitter indoors in a dry location only 1A 1B 1 m 3ft 1C __________________________________________________ Lay Out the System WARNING Underground cables can carry high voltage Have all...

Страница 8: ...eed to be buried From the Fence Transmitter run the wire to A A to B B to C C to D D to E E to A twist the wires from A back to the Fence Transmitter See the Install the BoundaryWire section for more...

Страница 9: ...nded that you cut and splice the BoundaryWire between each twisted section The signal cannot be cancelled by running the wire through plastic or metal piping Splicing shielded cable to the BoundaryWir...

Страница 10: ...rning Zone at the maximum width 5 Plug the Power Adapter into the Power Socket and a working outlet The Power Adapter comes with the North American plug installed and additional plugs for the UK Europ...

Страница 11: ...ow often your pet tests the system and receives a Static Correction Check the Receiver Collar every month to ensure the battery is working properly A replacement PetSafe battery RFA 67D 11 can be foun...

Страница 12: ...Correction The numbers on the BoundaryWidth Control knob indicate signal strength and are not representative of BoundaryWidth footage If adjusting the Boundary Width Control knob does not give the des...

Страница 13: ...can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as needed However make sure the BoundaryWidth is set at a high enough range f...

Страница 14: ...raining The Contact Points must have direct contact with your pet s skin on the underside of his neck CAUTION Please read and follow the instructions in this manual Proper fit of the collar is importa...

Страница 15: ...ed for good contact A collar that is too tight will increase the risk of pressure necrosis in the contact area 5 Allow your pet to wear the collar for several minutes then recheck the fit Check the fi...

Страница 16: ...aining session Be sure to contain your pet by another means during the training period e g pen tie out lead etc During training if you need to take your pet out of the Pet Area remove the Receiver Col...

Страница 17: ...to the Boundary Flags and if he decides to not move past the ags he is learning the system 11A __________________________________________________ Days 5 thru 8 Distraction Phase Perform three training...

Страница 18: ...training is complete remove every other Boundary Flag every 4 days until all ags are removed Save Boundary Flags for future use __________________________________________________ Taking Your Pet Out...

Страница 19: ...A to one half turn beyond finger tight Check the tightness weekly To Insert and Remove the Battery Please see Step 5 of this manual A To Set the Static Correction Level Read all steps before attempti...

Страница 20: ...rrection Level 1 Remove the clear plastic cover with the edge of the Test Light Tool to expose the Correction Level Button D B C 2 With the battery installed press the Correction Level Button and rele...

Страница 21: ...ction is produced by the Contact Points on the Receiver Collar not the Boundary Wire With proper use the system is safe for all I have a small pet and a large pet will this work for me Yes Since the P...

Страница 22: ...smit through the walls of your house Make sure BoundaryWires are twisted from Boundary to the FenceTransmitter I have an inconsistent signal Make sure Fence Transmitter is at least 1 m 3 ft from large...

Страница 23: ...iver Collar does not beep and the Test Light does not ash replace the battery in the Receiver Collar If it still does not beep and the Test Light does not ash contact the Customer Care Centre 11 If th...

Страница 24: ...duct they shall be binding on you as if incorporated herein ___________________________________________ Compliance This equipment has been tested and found to comply with the EU R TTE Directive Before...

Страница 25: ...ther patents pending 400 1194 00 1 2010 Radio Systems Corporation Layout Grid Sch ma d installation Ontwerpraster Cuadr cula de distribuci n Plantilla de montaje Plantilla de montaje Udl gningsnet 7 6...

Отзывы: