Step
5
Prepare the Receiver Collar (PIG19-10761)
There are two sets of Contact Points that can be used on y our receiver. Your Receiver Collar
comes with the shor t Contact Points installed. The longer Contact Points should be used
on dogs with long hair. Tighten the Contact Points using Test Light Tool (
5A
) one-half turn
beyond finger tight. Check the tightness weekly.
To Insert and Remove the Battery
Note: Do not install the battery while the Receiver Collar is on your pet.
This Receiver Collar utilizes a replaceable PetSafe
®
battery (RFA-67D-11). This unique battery
is designed to make battery replacement easier and increase water protection.
To insert the battery, align the symbols on the battery (arrow) and Receiver Collar (triangle)
(
5B
). Use the edge of the Test Light Tool to turn the battery clockwise until the arrow lines up
with the lock symbol on the housing.
To remove the battery, turn the battery counter-clockwise using the edge of the Test Light
Tool (
5C
).
WARNING
DO NOT attempt to cut into or pry open the battery. Be sure to discard the used battery properly.
Battery life will vary depending on how often your pet tests the system and receives a Static Correction. Check the
Receiver Collar every month to ensure the battery is working properly.
A replacement PetSafe
®
battery (RFA-67D-11) can be found at many retailers. Contact the Customer Care
Centre or visit our web site at www.petsafe.net to locate a retailer near you.
Over Correction Protection
In the unlikely event that your pet “freezes” in the Static Correction Zone, this feature limits the static correction
duration to a maximum of 30 seconds. While the system locks out further static correction, the warning tone will
continue until the pet leaves the Static Correction Zone.
__________________________________________________
Set the Boundary Width
and Test the Receiver Collar
The Boundary Control Switch on the side of the
Fence Transmitter has three settings (
6A
). Setting
B
is used for most properties. The following table will
indicate the setting you should use.
Amount of Wire
Setting
Up to 396 m (1300 ft)
B
396 m - 732 m (1300 ft - 2400 ft)
C
Greater than 732 m (2400 ft)
A
Use the Boundary Width Control knob to set the
width of the Warning Zone and Static Correction
Zone (
6B
). Set the Boundary Width as wide as
possible to give your pet the widest Warning and
Static Correction Zones without reducing the
6A
5
2
8
4
10
3
9
1
7
0
6
5
2
8
4
10
3
9
1
7
0
6
6B
Step
6