background image

14 1-800-732-2677

Prepare the Receiver Collar

Your Receiver Collar comes with short Contact Points installed. Use the Long Contact Points 

for pets with long or thick hair. Tighten the Contact Points using Test Light Tool (

5A

) one-half 

turn beyond finger tight. Check the tightness weekly.

To Insert and Remove the Battery

Note: Do not install the battery while the Receiver Collar is on your pet.

5A

1.  Remove the screws with a Phillips screwdriver.
2.  Remove the Battery Lid (

5B

).

3.  Install a 9-volt alkaline battery (

5C

).

4.  Replace the Battery Lid (

5C

).

5.  Reinstall the screws. Do not over-tighten the screws.
If the Receiver Indicator Light is flashing every 4 to 5 seconds, battery 

replacement is required. Remove the old battery from the Receiver 

Collar. Discharge all power by holding the correction level button down 

until the light is no longer illuminated. Replace with a new battery. 
A replacement PetSafe

®

 9-volt alkaline battery (PAC11-12067) can be 

found at many retailers. Contact the Customer Care Center or visit our 

web site at www.petsafe.net to locate a retailer near you. 

5B

5C

To Set the Static Correction Level

Read all steps before attempting to set the Static Correction Level.
1.  Remove the clear plastic cover with the Test Light Tool to 

expose the Correction Level Button (

5D

).

2.  With the battery installed, press the Correction Level 

Button and release when the Receiver Indicator Light 

lights up (

5E

).

3.  The Receiver Indicator Light will emit a series of flashes 

representing the Static Correction Level.

4.  Increase the Static Correction Level by pressing and 

releasing the Correction Level Button within 

5 seconds of the previous series of flashes.

5.  After setting the Static Correction Level, replace the cover 

to protect the Correction Level Button.

5E

5D

The Static Correction levels increase in strength from 1 to 5. Pushing the Correction Level Button while the Receiver 

Collar is on level 5 will cause the Receiver Collar to revert to Level 1. Refer to the Function and Response Table to 

choose the Static Correction level that best fits your pet.
The Receiver Collar will emit a Warning Tone and vibrate whenever your pet enters the Warning Zone, no matter 

what correction level the Receiver Collar is set to.  If your pet continues into the Correction Zone, and the Receiver 

Collar is set to level 2 or above, he will receive a Static Correction. The Receiver Collar is equipped to automatically 

increase the level of Static Correction the longer your pet remains in the Static Correction Zone if the collar is set at 

level 2 or above.
The Receiver Indicator Light acts as a low battery indicator, flashing every 4 to 5 seconds when battery replacement 

is required. Test your Receiver Collar at least once a month to verify that it is functioning properly and that it 

activates at the Boundary Wire.

Step 

5

Содержание PIG00-100777

Страница 1: ...stubborn dog in ground fence operating and training guide Model Number PIG00 10777 Please read this entire guide before beginning...

Страница 2: ...sive dogs can cause severe injury or death to their owners and others If you are not sure that this product is right for your dog please talk to your veterinarian or a certified trainer Underground ca...

Страница 3: ...shave the dog s neck this may lead to a rash or infection The Receiver Collar should not be on your dog when the system is tested Your pet may receive an unintended correction The Boundary Width of th...

Страница 4: ...is available online at www petsafe net Table of Contents Components 5 Other Items You May Need 5 How the System Works 6 Key Definitions 6 Operating Guide 7 Locate the Fence Transmitter 7 Lay Out the...

Страница 5: ...PLE ASE REA D THI S ENTIR E GU IDE BEF OR E BEG INN ING Mo del Num ber PIG00 10777 Other Items You May Need Additional wire and flags Part PRFA 500 Tape measure Small Phillips screwdriver Drill mounti...

Страница 6: ...o signal from the Boundary Wire Correction Level Button Adjusts the level of Static Correction your pet receives in the Static Correction Zone Receiver Indicator Light Indicates the level of correctio...

Страница 7: ...ency 1C To mount the Fence Transmitter screw the mounting bracket onto a stationary surface such as a wall and slide the Fence Transmitter onto the bracket Once you have mounted the Fence Transmitter...

Страница 8: ...e recommend setting a Boundary Width for the Warning and Static Correction Zones to approximately 12 20 feet 6 to 10 feet on each side of the wire Avoid making passageways too narrow for your pet to m...

Страница 9: ...east 5 feet Twist the wire from A back to the Fence Transmitter E B D C A 5 2H Sample 5 2H Lake Access Double Loop From the Fence Transmitter run the wire to A A to B make a U turn and go to C C to D...

Страница 10: ...to something secure and insert the other end in a power drill Pull the wire taut The drill enables you to twist the wire quickly Twist the Boundary Wire 10 to 12 times per foot to cancel the signal On...

Страница 11: ...connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardous surges Turn off power to outlet before you install o...

Страница 12: ...wires and release the tab Make sure the wires do not touch each other at the terminals Verify that the boundary loop and transmitter wires connect to the proper Surge Protector terminals Reversed con...

Страница 13: ...r Lights should come on If this does not happen see the Troubleshooting section Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thund...

Страница 14: ...led press the Correction Level Button and release when the Receiver Indicator Light lights up 5E 3 The Receiver Indicator Light will emit a series of flashes representing the Static Correction Level 4...

Страница 15: ...Run Through Prevention sound is an intermittent tone Over Correction Protection In the unlikely event that your pet freezes in the Static Correction Zone this feature limits the static correction dur...

Страница 16: ...warning tone you have identified the Boundary Width distance Static Correction Zone Two seconds after the warning tone the test light will begin to flash This flashing light can aid you in identifyin...

Страница 17: ...g Fence The Boundary Wire of the PetSafe Stubborn Dog In Ground Fence can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as need...

Страница 18: ...before burying 7C 7D Place the Boundary Flags The Boundary Flags are visual reminders for your pet of where the Warning Zone is located 1 Place the Test Light contacts on the contact points and hold t...

Страница 19: ...comfortable while they wear stainless steel contacts Some pets are sensitive to contact pressure You may find after some time that your pet is very tolerant of the collar If so you may relax some of...

Страница 20: ...own the training schedule add additional days of training or increase the amount of play time with your pet in the Pet Area Common stress signals include Pet pulling on leash toward the house Ears tuc...

Страница 21: ...orrection Zone the Receiver Collar will begin to beep and vibrate 10B Allow your pet to stay in the Static Correction Zone for up to 2 seconds then gently help him back into the Pet Area 10C Immediate...

Страница 22: ...treats available hot dogs or lunch meat work well Have your pet s favorite play toy available Create distractions to tempt your pet to enter the Static Correction Zone such as Have a family member cro...

Страница 23: ...satisfied your pet s training is complete remove every other Boundary Flag every 4 days until all flags are removed Save Boundary Flags for future use Taking Your Pet Out of the Pet Area Important Re...

Страница 24: ...with the Test Light walking toward the Boundary Wire If the Test Light flashes check the fit of the Receiver Collar Trim your pet s fur where the Contact Points touch the neck and or switch to the lo...

Страница 25: ...omer Care Center If a Surge Protector is installed unplug the Surge Protector and plug the power adapter directly into the outlet If the Transmitter operates without the Surge Protector contact the Cu...

Страница 26: ...peat the above test on each collar 10 Keep Boundary Width Control Knob position at 10 Set the Boundary Control Switch to A Approach loop with Receiver Collar as in Step 7 and verify the Receiver Colla...

Страница 27: ...installed 5 At wire splices without reinforcements knots refer to Figure 3E If you still cannot find the break in the Boundary Wire there are two options for locating it Option 1 It is recommended to...

Страница 28: ...d trainer Proper use includes reviewing the entire Guide provided with your Product and any specific Caution statements 3 No Unlawful or Prohibited Use This Product is designed for use with pets only...

Страница 29: ...interfered receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different to that to which the receiver is connected Contact...

Страница 30: ...r change of mind or for any other reason outside of these Warranty terms Claims Procedure Any claim made under this Warranty should be made directly to Radio Systems Australia Pty Ltd Customer Care Ce...

Страница 31: ...www petsafe net 31...

Страница 32: ...Systems Corporation 10427 PetSafe Way Knoxville TN 37932 1 800 732 2677 www petsafe net Protected by US Patents 6 538 617 400 1416 3 2006 Radio Systems Corporation 3 000 7 62 cm Drill Here Drill Here...

Отзывы: