background image

2 1-800-732-2677

Important Safety Information

Explanation of Attention Words and Symbols used in this guide

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that 

follow this symbol to avoid possible injury or death.

WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result 

in minor or moderate injury.

CAUTION, used without the safety alert symbol, indicates a hazardous situation which, if not avoided, could 

result in harm to your pet.

NOTICE is used to address safe use practices not related to personal injury.

•  Not for use with aggressive dogs. Do not use this product if your dog is prone to aggressive 

behavior. Aggressive dogs can cause severe injury or death to their owners and others. If you are 

not sure that this product is right for your dog, please talk to your veterinarian or a certified trainer.

•  Underground cables can carry high voltage. Have all underground cables marked before you dig 

to bury your wire. In most areas this is a free service. Avoid these cables when you dig.

•  Follow all safety instructions for your power tools. Be sure to always wear your safety goggles.
•  Do not install, connect, or remove your system during a lightning storm. If the storm is close 

enough for you to hear thunder, it is close enough to create hazardous surges.

•  Risk of electric shock. Use the Fence Transmitter and Surge Protector indoors in dry location only.

•  Turn off power to outlet before you install or remove your Surge Protector.
•  Risk of electrical shock or fire. Use Surge Protector only with a duplex outlet with center screw. Attach unit 

with long screw supplied.

•  Risk of injury. Wire on top of the ground may be a trip hazard; Use care in how you place your 

wires.

Содержание PIG00-100777

Страница 1: ...stubborn dog in ground fence operating and training guide Model Number PIG00 10777 Please read this entire guide before beginning...

Страница 2: ...sive dogs can cause severe injury or death to their owners and others If you are not sure that this product is right for your dog please talk to your veterinarian or a certified trainer Underground ca...

Страница 3: ...shave the dog s neck this may lead to a rash or infection The Receiver Collar should not be on your dog when the system is tested Your pet may receive an unintended correction The Boundary Width of th...

Страница 4: ...is available online at www petsafe net Table of Contents Components 5 Other Items You May Need 5 How the System Works 6 Key Definitions 6 Operating Guide 7 Locate the Fence Transmitter 7 Lay Out the...

Страница 5: ...PLE ASE REA D THI S ENTIR E GU IDE BEF OR E BEG INN ING Mo del Num ber PIG00 10777 Other Items You May Need Additional wire and flags Part PRFA 500 Tape measure Small Phillips screwdriver Drill mounti...

Страница 6: ...o signal from the Boundary Wire Correction Level Button Adjusts the level of Static Correction your pet receives in the Static Correction Zone Receiver Indicator Light Indicates the level of correctio...

Страница 7: ...ency 1C To mount the Fence Transmitter screw the mounting bracket onto a stationary surface such as a wall and slide the Fence Transmitter onto the bracket Once you have mounted the Fence Transmitter...

Страница 8: ...e recommend setting a Boundary Width for the Warning and Static Correction Zones to approximately 12 20 feet 6 to 10 feet on each side of the wire Avoid making passageways too narrow for your pet to m...

Страница 9: ...east 5 feet Twist the wire from A back to the Fence Transmitter E B D C A 5 2H Sample 5 2H Lake Access Double Loop From the Fence Transmitter run the wire to A A to B make a U turn and go to C C to D...

Страница 10: ...to something secure and insert the other end in a power drill Pull the wire taut The drill enables you to twist the wire quickly Twist the Boundary Wire 10 to 12 times per foot to cancel the signal On...

Страница 11: ...connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardous surges Turn off power to outlet before you install o...

Страница 12: ...wires and release the tab Make sure the wires do not touch each other at the terminals Verify that the boundary loop and transmitter wires connect to the proper Surge Protector terminals Reversed con...

Страница 13: ...r Lights should come on If this does not happen see the Troubleshooting section Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thund...

Страница 14: ...led press the Correction Level Button and release when the Receiver Indicator Light lights up 5E 3 The Receiver Indicator Light will emit a series of flashes representing the Static Correction Level 4...

Страница 15: ...Run Through Prevention sound is an intermittent tone Over Correction Protection In the unlikely event that your pet freezes in the Static Correction Zone this feature limits the static correction dur...

Страница 16: ...warning tone you have identified the Boundary Width distance Static Correction Zone Two seconds after the warning tone the test light will begin to flash This flashing light can aid you in identifyin...

Страница 17: ...g Fence The Boundary Wire of the PetSafe Stubborn Dog In Ground Fence can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as need...

Страница 18: ...before burying 7C 7D Place the Boundary Flags The Boundary Flags are visual reminders for your pet of where the Warning Zone is located 1 Place the Test Light contacts on the contact points and hold t...

Страница 19: ...comfortable while they wear stainless steel contacts Some pets are sensitive to contact pressure You may find after some time that your pet is very tolerant of the collar If so you may relax some of...

Страница 20: ...own the training schedule add additional days of training or increase the amount of play time with your pet in the Pet Area Common stress signals include Pet pulling on leash toward the house Ears tuc...

Страница 21: ...orrection Zone the Receiver Collar will begin to beep and vibrate 10B Allow your pet to stay in the Static Correction Zone for up to 2 seconds then gently help him back into the Pet Area 10C Immediate...

Страница 22: ...treats available hot dogs or lunch meat work well Have your pet s favorite play toy available Create distractions to tempt your pet to enter the Static Correction Zone such as Have a family member cro...

Страница 23: ...satisfied your pet s training is complete remove every other Boundary Flag every 4 days until all flags are removed Save Boundary Flags for future use Taking Your Pet Out of the Pet Area Important Re...

Страница 24: ...with the Test Light walking toward the Boundary Wire If the Test Light flashes check the fit of the Receiver Collar Trim your pet s fur where the Contact Points touch the neck and or switch to the lo...

Страница 25: ...omer Care Center If a Surge Protector is installed unplug the Surge Protector and plug the power adapter directly into the outlet If the Transmitter operates without the Surge Protector contact the Cu...

Страница 26: ...peat the above test on each collar 10 Keep Boundary Width Control Knob position at 10 Set the Boundary Control Switch to A Approach loop with Receiver Collar as in Step 7 and verify the Receiver Colla...

Страница 27: ...installed 5 At wire splices without reinforcements knots refer to Figure 3E If you still cannot find the break in the Boundary Wire there are two options for locating it Option 1 It is recommended to...

Страница 28: ...d trainer Proper use includes reviewing the entire Guide provided with your Product and any specific Caution statements 3 No Unlawful or Prohibited Use This Product is designed for use with pets only...

Страница 29: ...interfered receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different to that to which the receiver is connected Contact...

Страница 30: ...r change of mind or for any other reason outside of these Warranty terms Claims Procedure Any claim made under this Warranty should be made directly to Radio Systems Australia Pty Ltd Customer Care Ce...

Страница 31: ...www petsafe net 31...

Страница 32: ...Systems Corporation 10427 PetSafe Way Knoxville TN 37932 1 800 732 2677 www petsafe net Protected by US Patents 6 538 617 400 1416 3 2006 Radio Systems Corporation 3 000 7 62 cm Drill Here Drill Here...