1.  Turn the power OFF to the outlet that the Surge Protector 

and Fence Transmitter will be plugged into.

2.  We recommend that, if possible, use the outlet center 

screw that holds the cover plate in place to secure the 

Surge Protector to the outlet. To do this, tape the top of 

the cover plate to the wall, then remove the cover plate 

center screw. Plug the Surge Protector into the lower outlet 

and then secure the cover plate using the longer screw 

included with the protector. The screw is for mechanical 

attachment only and does not ground the protector. 

Remove the tape and turn ON the power to the outlet.

3.  Run the Boundary Wire through a window, under a door, 

through a crawl space vent, or any other appropriate 

available access. You can also drill a hole through your wall. 

Fence Transmitter

Power

Adapter

Red Loop Tabs

Boundary Wires

(Twisted)

Boundary

Wire

Terminals

Transmitter

Wires

(Twisted)

Boundary Wire

Loop

Black 

Transmitter

Tabs

LP-4100

Power

Jack

Transmitter

Loop

4A

4.  Strip 

3

8

 inch of insulation from the ends of the Boundary Wire. Insert the stripped 

ends into the 2 left red connector holes on the bottom of the Surge Protector labeled 

“Loop” (

4B

). There should be 1 wire in each connector hole. Press the plastic tab, 

insert the wires and release the tab. Make sure the wires do not touch each other at 

the terminals.

Verify that the boundary loop and transmitter wires connect to the 

proper Surge Protector terminals. Reversed connections will result in an 

increased risk of surge related damage.

5.  Determine the length of wire needed to pass from the Surge Protector to the Fence 

Transmitter. Measure and cut 2 lengths of wire, then strip 

3

8

 inch of insulation at both 

ends. Twist the 2 lengths together, with at least 10-12 twists per foot, so the wires will 

not send out a signal.

LOOP      TRAN

SMITTER

Push Tab

Down

Insert bare end 

of wire into 

opened slot 

and release tab 

to lock.

4B

6.  Insert the ends of the the twisted transmitter wires into the right 2 black connectors at the bottom of the Surge 

Protector labeled “Transmitter”. 

7.  Press the red plastic tabs on the Fence Transmitter and insert the opposite ends of the twisted wire into the 

Boundary Wire Terminals.

8.  Turn the Boundary Width Control knob to 10. This will set the Boundary Width at the maximum width.
9.  Plug in the transmitter power adapter to the outlet on the front of the Surge Protector.
10. The Power Light and Loop Indicator Lights should come on. If this does not happen, see the “Troubleshooting” 

section.

For added protection, when unused for long periods of time or prior to thunderstorms, unplug  from the 

wall outlet and disconnect the loop boundary wires. This will prevent damage to the transmitter due to 

surges.

Содержание PIG00-100777

Страница 1: ...stubborn dog in ground fence operating and training guide Model Number PIG00 10777 Please read this entire guide before beginning...

Страница 2: ...sive dogs can cause severe injury or death to their owners and others If you are not sure that this product is right for your dog please talk to your veterinarian or a certified trainer Underground ca...

Страница 3: ...shave the dog s neck this may lead to a rash or infection The Receiver Collar should not be on your dog when the system is tested Your pet may receive an unintended correction The Boundary Width of th...

Страница 4: ...is available online at www petsafe net Table of Contents Components 5 Other Items You May Need 5 How the System Works 6 Key Definitions 6 Operating Guide 7 Locate the Fence Transmitter 7 Lay Out the...

Страница 5: ...PLE ASE REA D THI S ENTIR E GU IDE BEF OR E BEG INN ING Mo del Num ber PIG00 10777 Other Items You May Need Additional wire and flags Part PRFA 500 Tape measure Small Phillips screwdriver Drill mounti...

Страница 6: ...o signal from the Boundary Wire Correction Level Button Adjusts the level of Static Correction your pet receives in the Static Correction Zone Receiver Indicator Light Indicates the level of correctio...

Страница 7: ...ency 1C To mount the Fence Transmitter screw the mounting bracket onto a stationary surface such as a wall and slide the Fence Transmitter onto the bracket Once you have mounted the Fence Transmitter...

Страница 8: ...e recommend setting a Boundary Width for the Warning and Static Correction Zones to approximately 12 20 feet 6 to 10 feet on each side of the wire Avoid making passageways too narrow for your pet to m...

Страница 9: ...east 5 feet Twist the wire from A back to the Fence Transmitter E B D C A 5 2H Sample 5 2H Lake Access Double Loop From the Fence Transmitter run the wire to A A to B make a U turn and go to C C to D...

Страница 10: ...to something secure and insert the other end in a power drill Pull the wire taut The drill enables you to twist the wire quickly Twist the Boundary Wire 10 to 12 times per foot to cancel the signal On...

Страница 11: ...connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardous surges Turn off power to outlet before you install o...

Страница 12: ...wires and release the tab Make sure the wires do not touch each other at the terminals Verify that the boundary loop and transmitter wires connect to the proper Surge Protector terminals Reversed con...

Страница 13: ...r Lights should come on If this does not happen see the Troubleshooting section Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thund...

Страница 14: ...led press the Correction Level Button and release when the Receiver Indicator Light lights up 5E 3 The Receiver Indicator Light will emit a series of flashes representing the Static Correction Level 4...

Страница 15: ...Run Through Prevention sound is an intermittent tone Over Correction Protection In the unlikely event that your pet freezes in the Static Correction Zone this feature limits the static correction dur...

Страница 16: ...warning tone you have identified the Boundary Width distance Static Correction Zone Two seconds after the warning tone the test light will begin to flash This flashing light can aid you in identifyin...

Страница 17: ...g Fence The Boundary Wire of the PetSafe Stubborn Dog In Ground Fence can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as need...

Страница 18: ...before burying 7C 7D Place the Boundary Flags The Boundary Flags are visual reminders for your pet of where the Warning Zone is located 1 Place the Test Light contacts on the contact points and hold t...

Страница 19: ...comfortable while they wear stainless steel contacts Some pets are sensitive to contact pressure You may find after some time that your pet is very tolerant of the collar If so you may relax some of...

Страница 20: ...own the training schedule add additional days of training or increase the amount of play time with your pet in the Pet Area Common stress signals include Pet pulling on leash toward the house Ears tuc...

Страница 21: ...orrection Zone the Receiver Collar will begin to beep and vibrate 10B Allow your pet to stay in the Static Correction Zone for up to 2 seconds then gently help him back into the Pet Area 10C Immediate...

Страница 22: ...treats available hot dogs or lunch meat work well Have your pet s favorite play toy available Create distractions to tempt your pet to enter the Static Correction Zone such as Have a family member cro...

Страница 23: ...satisfied your pet s training is complete remove every other Boundary Flag every 4 days until all flags are removed Save Boundary Flags for future use Taking Your Pet Out of the Pet Area Important Re...

Страница 24: ...with the Test Light walking toward the Boundary Wire If the Test Light flashes check the fit of the Receiver Collar Trim your pet s fur where the Contact Points touch the neck and or switch to the lo...

Страница 25: ...omer Care Center If a Surge Protector is installed unplug the Surge Protector and plug the power adapter directly into the outlet If the Transmitter operates without the Surge Protector contact the Cu...

Страница 26: ...peat the above test on each collar 10 Keep Boundary Width Control Knob position at 10 Set the Boundary Control Switch to A Approach loop with Receiver Collar as in Step 7 and verify the Receiver Colla...

Страница 27: ...installed 5 At wire splices without reinforcements knots refer to Figure 3E If you still cannot find the break in the Boundary Wire there are two options for locating it Option 1 It is recommended to...

Страница 28: ...d trainer Proper use includes reviewing the entire Guide provided with your Product and any specific Caution statements 3 No Unlawful or Prohibited Use This Product is designed for use with pets only...

Страница 29: ...interfered receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different to that to which the receiver is connected Contact...

Страница 30: ...r change of mind or for any other reason outside of these Warranty terms Claims Procedure Any claim made under this Warranty should be made directly to Radio Systems Australia Pty Ltd Customer Care Ce...

Страница 31: ...www petsafe net 31...

Страница 32: ...Systems Corporation 10427 PetSafe Way Knoxville TN 37932 1 800 732 2677 www petsafe net Protected by US Patents 6 538 617 400 1416 3 2006 Radio Systems Corporation 3 000 7 62 cm Drill Here Drill Here...

Отзывы: