How the System Works

The PetSafe

®

 Free to Roam Wireless Fence

 system has been proven safe, 

comfortable, and effective for pets over 5 pounds. The system works by 
transmitting a radio signal up to 90 feet in all directions. You temporarily 
define the Pet Area with Boundary Flags for a visual aid in training your 
pet. Your pet wears a Receiver Collar with Contact Points that touch his 
neck, and, once trained, is allowed to roam freely in the Pet Area. When 
your pet reaches the Boundary Zone, the Receiver Collar gives a warning 
tone before delivering a safe Static Correction through the Contact Points 
to get his attention until he returns to the Pet Area.

Key Definitions

Pet Area:

 Distance from the Transmitter where your pet can roam freely.

Boundary Zone:

 2 to 3 foot wide area outside the Pet Area where 

your pet’s Receiver Collar will begin to tone and then begin to deliver 
a Static Correction. The correction will start in the Boundary Zone and 
continue anywhere beyond the Pet Area. 

Note: 

The Receiver Collar is equipped with a safety time-out feature that will 

Содержание PIF00-15002

Страница 1: ...Please read this entire guide before beginning PIF00 15002 Free to Roam Wireless Fence Wireless Collar Operating Guide...

Страница 2: ...rranty please register your product within 30 days at www petsafe net By registering and keeping your receipt you will enjoy the product s full warranty and should you ever need to call the Customer C...

Страница 3: ...y hazards Obey all safety messages that follow this symbol to avoid possible injury or death WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTIO...

Страница 4: ...rcuit mix old and new batteries dispose of in fire or expose to water When batteries are stored or disposed they must be protected from shorting Dispose of used batteries properly This PetSafe Free to...

Страница 5: ...amage economic loss or any consequential damages sustained as a result of any animal crossing the boundary Proper fit of the collar is important A collar worn for too long or made too tight on the pet...

Страница 6: ...nd 48 hours see your veterinarian For additional information on bed sores and pressure necrosis please visit our website These steps will help keep your pet secure and comfortable Millions of pets are...

Страница 7: ...ted whenever an adjustment is made to the Transmitter setting to prevent unintended corrections to your pet If you use a collar and leash for training be sure the extra collar does not put pressure on...

Страница 8: ...freely in the Pet Area When your pet reaches the Boundary Zone the Receiver Collar gives a warning tone before delivering a safe Static Correction through the Contact Points to get his attention unti...

Страница 9: ...r ON OFF and adjusts the level of Static Correction your pet receives outside the Pet Area Receiver Indicator Light Indicates the level of correction at which the Receiver Collar is set This light als...

Страница 10: ...PetSafe battery RFA 67 This unique battery is designed to make battery replacement easier and increase water protection Once you insert the battery and turn it to the lock position the unit will be tu...

Страница 11: ...at many retailers Contact the Customer Care Center at 1 800 732 2677 or visit our web site at www petsafe net to locate a retailer near you Risk of explosion if batteries are replaced by an incorrect...

Страница 12: ...atus followed by the red Receiver Indicator Light flashing the Static Correction Level Settings Turn the Receiver Collar OFF Press and hold the Mode Button continuously for 5 seconds The red Receiver...

Страница 13: ...ed flashes representing the Static Correction Level 3 Increase the Static Correction Level by pressing and releasing the Mode Button within 5 seconds of the previous series of flashes The Static Corre...

Страница 14: ...ion the Receiver Collar Indicator Light will flash for the first 30 seconds after a battery is installed or the receiver is turned on to indicate the battery status as shown in the table below Receive...

Страница 15: ...s per second Warning Tone Warning Tone Fast pulsating red 3 flashes per second Tone for duration of Static Correction Static Correction being delivered up to 15 seconds Continuous green 10 seconds No...

Страница 16: ...Correction Timid 3 Red Flashes 3 Medium Low Static Correction Timid or Average 4 Red Flashes 4 Medium Static Correction Average Energy 5 Red Flashes 5 Medium High Static Correction Average or High Ene...

Страница 17: ...eyond the Pet Area this feature limits the Static Correction duration to 15 seconds While the system locks out further Static Correction the Green light will remain ON for 10 seconds In the unlikely e...

Страница 18: ...ne holding the Receiver collar at your pet s neck level 1G until the Test Light flashes 1H Save Test Light for future testing Note If the Test Light does not flash check the battery status by turning...

Страница 19: ...the collar is important A collar worn for too long or made too tight on the pet s neck may cause skin damage Ranging from redness to pressure ulcers this condition is commonly known as bed sores Avoid...

Страница 20: ...bed sores and pressure necrosis please visit our website These steps will help keep your pet secure and comfortable Millions of pets are comfortable while they wear stainless steel contacts Some pets...

Страница 21: ...t standing comfortably 2A 3 To make it easier to hear the warning tone place the Receiver Collar on your pet with the logo side of Receiver facing up 4 Center the Contact Points underneath your pet s...

Страница 22: ...eck the fit b Check the fit again as your pet becomes more comfortable with the Receiver Collar 6 Trim the collar as follows 2C a Mark the desired length of the Receiver Collar with a pen Allow for gr...

Страница 23: ...e net 23 Re Thread the Collar The slide buckle prevents the collar from becoming loose around your pet s neck The ridges must be facing up the collar will slip if it is not properly threaded Slide Buc...

Страница 24: ...the Pet Area Option 2 Replace the Receiver Collar with a regular collar and leash Walk your pet out of the Pet Area while giving a command such as OK at a specific place of the Boundary Zone the end o...

Страница 25: ...t Contact the Customer Care Center at 1 800 732 2677 or visit our website at www petsafe net to locate a retailer near you Is there a hand held remote Transmitter that will work with the Wireless syst...

Страница 26: ...rately What happens if the power goes out The Wireless system is designed to recognize power outages and shuts down without activating the Receiver Collar However if your pet is near the Boundary Zone...

Страница 27: ...s on how frequently your pet tests the Boundary Zone The receiver Indicator Light acts as a low battery indicator flashing every 4 to 5 seconds when replacement is required Can I place the receiver on...

Страница 28: ...Contact Points irritating the skin Discontinue use of the Receiver Collar for a few days If the condition persists beyond 48 hours see your veterinarian Once the skin returns to normal replace the Re...

Страница 29: ...iver Collar battery The Receiver Collar tone is not sounding or administering a Static Correction Check that the Transmitter is plugged into a working 120 volt outlet turned on the Power Light is on a...

Страница 30: ...hin the Pet Area The Transmitter may need to be moved to adjust the Pet Area to include the entire house If relocating the Transmitter remove the Receiver Collar from your pet before turning the Trans...

Страница 31: ...ientation of the Receiver Collar as your pet enters the Boundary Zone The Receiver Collar activates in the middle of the yard The Receiver Collar activates when it loses the Transmitter signal This so...

Страница 32: ...onger Contact Points Increase the Static Correction Level Repeat training steps to reinforce training My pet reacts strongly to the Static Correction and has become fearful Lower the Static Correction...

Страница 33: ...he Transmitter goes out My next door neighbor has a Containment system and the Receiver Collar does not activate near their property Your neighbor s containment signal may interfere with the operation...

Страница 34: ...rical burns The energy in an output pulse is only a few thousandths of a Joule it is similar in nature to the static pulse that you may feel when getting out of your car In some cases pressure ulcers...

Страница 35: ...se This Product is designed for use with pets where training is desired The specific temperament of your pet may not work with this Product If you are unsure whether this is appropriate for your pet p...

Страница 36: ...eserves the right to change the terms conditions and notices under which this Product is offered Compliance FCC IC This Class B digital apparatus complies with Canadian RSS 310 This equipment has been...

Страница 37: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different to that to which the receiver is connected Contact the Customer Care Center at 1 800 732 267...

Страница 38: ...y Customer Care International USA Canada Tel 800 732 2677 Monday Friday 8 AM 8 PM Saturday 9 AM 5 PM Australia Tel 1800 786 608 Monday Friday 8 30 AM 5 PM New Zealand Tel 0800 543 054 Monday Friday 10...

Страница 39: ...douswaste perchlorate Warranty One Year Non Transferrable Limited Warranty This Product has the benefit of a limited manufacturer s warranty Complete details of the warranty applicable to this Product...

Страница 40: ...r entity who originally purchases the Product or a gift recipient of a new product that is unopened and in its original packaging When serviced by Radio Systems Customer Service Radio Systems covers l...

Страница 41: ...nty terms Claims Procedure Any claim made under this Warranty should be made directly to Radio Systems Australia Pty Ltd Customer Care Centre at Radio Systems Australia Pty Ltd PO Box 7266 Gold Coast...

Страница 42: ...the consumer will be required to return the Product to Radio Systems at the consumer s own expense Radio Systems will test and replace the faulty unit or its components and return to the consumer free...

Страница 43: ...www petsafe net 43 Should you have any queries or require any further information please contact our Customer Care Centre on 1800 786 608 Australia or 0800 543 054 New Zealand...

Страница 44: ...adio Systems Corporation 10427 PetSafe Way Knoxville TN 37932 1 800 732 2677 www petsafe net Protected by US Patents 6 879 300 6 921 089 7 142 167 and D515 027 400 1860 4 2016 Radio Systems Corporatio...

Отзывы: