10
Perlick.is.committed.to.continuous.improvement..Therefore,.we.reserve.the.right.to.change.specifications.without.prior.notice.
OWNERS.INSTRUCTIONS
DETERGENT
CALIBRATING THE CHEMICAL SYSTEM
RINSE AID
Detergent and Rinse Additive:
Low Foaming Liquid
Position 1: Low soil and soft water
Position 2: Medium soil and soft water
Position 3: High soil and hard water
TO PRIME:
Depress buttons until chemicals appear in windows.
Sanitizer:
Adjust to min. 50 ppm chlorine
(see Test Kit Instructions)
EPA Registered
Non–Foaming Liquid
Alkaline
Non–Chlorinated
Low Foaming Liquid
CHLORINE
PRIME
PRIME
PRIME
ON
3
3
1
+
_
2
2
OFF
CHEMICAL
SWITCH
DETERGENT
RINSE AID
SANITIZER
Chemical Control Panel
ITEM NO.
dESCRIPTION
FUNCTION
.
1
ChEMCIAL SySTEM
.
Should.be.kept.in.the.ON.position.except.during.cleaning..
.
.
.
POwER SwITCh
.
When.switch.is.in.the.OFF.position,.the.Chemical.OFF...
.
.
.
.
light.on.the.instrument.panel.will.be.illuminated.
.
2
dETERgENT CONTROL kNOb
.
Controls.detergent.concentration.with.three,.pre-calibrated.
.
.
.
settings:
.
.
.
.
.
1.=.Lowest.Concentration
.
.
.
.
.
2.=.Medium.Concentration
.
.
.
.
.
3.=.Highest.Concentration
.
3
SANITIZER CONTROL kNOb
.
Controls.sanitizer.concentration.with.an.infinite.adjustment..
.
.
.
.
to.precisely.dispense.sanitizer.to.the.required.minimum.of..
.
.
.
.
50.ppm.
4
RINSE AddITIVE CONTROL
.
Controls.rinse.aid.concentration.with.three,.pre-calibrated..
.
.
.
.
settings:
.
.
.
.
.
1.=.Lowest.Concentration
.
.
.
.
.
2.=.Medium.Concentration
.
.
.
.
.
3.=.Highest.Concentration
5
PRIME SwITChES
.
Fills.chemical.lines.without.running.glasswasher..Power..
.
.
.
.
ON.light.must.be.illuminated.
6
ChEMICAL FLOw INdICATORS
.
These.windows.illuminate.when.a.chemical.is.flowing.. .
.
.
.
.
during.a.wash.cycle.or.when.chemical.lines.are.being.. .
.
.
.
.
primed,.providing.a.visual.indicator.of.chemical.flow.