3
Perlick.is.committed.to.continuous.improvement..Therefore,.we.reserve.the.right.to.change.specifications.without.prior.notice.
HOT WATER
INLET 1/2” [13]
MALE N.P.T.
(R.H. & STD.
UNITS)
HOT WATER INLET
1/2” [13] MALE N.P.T.
(L.H. UNITS)
HOT WATER
INLET 1/2” [13]
MALE N.P.T.
(L.H. UNITS)
HOT WATER
INLET 1/2” [13]
MALE N.P.T.
(R.H. & STD.
UNITS)
MOdEL NOS.
PkbR24
PkbR24L
PkbR24R
WASH.TANK.CAPACITY.(gals.).
1.
1.
1
CYCLE.TIME.(sec.).
120.
120.
120
WASH.TIME.(sec.).60.
60.
60
SANITIZER.TIME.(sec.).
35.
35.
35
GLASSES.WASHED.PER..
HR..(2
1
/
2
”.dia.).
.
720.
720.
720
TANK.HEATER.(watts).
650.
650.
650
WASH.PUMP.CAPACITY.(gals./min.).
24.
24.
24
DRAIN.FLOW.(gals/cycle).
1.67.
1.67.
1.67
EXHAUST.REQUIREMENT.
None.
None.
None
MAXIMUM.GLASS.HEIGHT.
10”.
10”.
10”
Ship.wt.lbs..(kg). .
225.(103).
225.(103).
225.(103)
ELECTRICAL.
120.Volt,.60.Hz.,.single.phase.AC..5.4.amps,.furnished.with.6.foot.power.cord.and.standard.
.
3.prong.NEMA.style.5-15P.
PLUMBING.
hot water Inlet Connection
:.1/2.”.NPTM..Incoming.Hot.Water:.130–140°.F,.at.30-60.psi
.
with..a.flow.rate.of.4.0.gal/min..Drain:.11/4.IPS.PVC.socket.connection.to.include.an.air.gap...
.
Plumbers hookup kit
:.Includes.water.hammer.arrestor,.stop.valve.and.union..
Important:
.
Failure.to.install..the.Glasswasher.with.Plumbers.Hookup.Kit.can.damage.the.hot.water.
.
solenoid.valve..Machine.
failure due to improper installation is not covered by Perlick’s warranty.
WATER.HARDNESS.
Water.containing.more.than.15.GPG.will.require.a.water.softener..
Caution
:.Parts.failure.. .
.
caused..by.hard.water.are.not.covered.under.
Perlick’s warranty.
DETERGENT,.SANITIZER.and..
detergent
:.A.heavy-duty.liquid.warewashing.detergent.containing.water.conditioners.
RINSE.AID.
Chlorine Sanitizer
:.Any.EPA.registered.chlorine.can.be.used..The.EPA.marking.can.be.found..
.
on.the.container.label..
Rinse Aid
:.A.low-foaming.warewashing.rinse.aid.containing.water..
.
conditioners..
Note: To ensure maximum glasswasher performance. It is important to select
the appropriate detergent and rinse aid for specific water conditions. These chemicals can be
purchased from a local chemical supplier or food service distributor.
OPTIONAL.ACCESSORIES.
•.Low.Sanitizer.shut.down.kit.-.#61945...•.Glass.Rack.-.#50470-2.
Sizes.and.Specifications..
PKBR24.Glasswashers
All plumbing and chemical lines must be routed so that the glasswasher can be pulled out for service.