10
IDS-710 Hardware Installation Guide
Connecting Power to the IDS Switch
The IDS switch has two power inputs that can be connected simultaneously to provide
redundant power. If one power source fails the other source acts as a backup, and powers
the switch
Wiring with suitable temperature ratings must be used. Refer to specification section for
details. Use copper wire only if the terminal is only for connection to copper wire.
1. Ensure the power source is off prior to connection.
2. Strip both (12-20AWG) wires 7-8 mm(5/16th).
3. Loosen the terminal block screws and connect positive (+) / negative (-) wires into the
+/- terminals.
4. Tighten terminal screws (0.5Nm torque). Ensure the wires are securely fastened.
5. Re-insert the Terminal Block connector if removed, Turn on power source. Check
LED indicators in the guide for power status
6. Connect P2 (power source 2, beginning at Step 1)
7. Ensure that there is one individual conductor for each clamping point.
.
Wiring the Relay Alarm
The IDS switch has a relay with a Normally Open (NO) terminal pair which supports a
resistive load. The relay connections are located next to the power connections. Using
this, the IDS switch can be connected to an external powered device such as a siren or
light for visual or audible notification of an alarm status.
1. Ensure the power source is off prior to connection.
2. Strip 2x12-20AWG (3.31 mm² -0.52 mm²) twisted pair copper wires 7-8 mm.
3. Loosen the terminal block screws and connect wires into the terminals.
4. Tighten terminal screws. Ensure the wires are securely fastened.
5. Re-insert the Terminal block connector if removed.
6. Turn on power source.
.
Warning:
Ensure power has been removed at the source of the alarm circuit prior to pro
-
ceeding with connections to the alarm relay.
Warning:
Ensure the voltage and current supplied by the alarm circuits are within the
stated Alarm Relay specifications.
Wiring Digital Input
The IDS switch has a one Dry Contact digital input. This can sense a dry contact. On this
terminal pair the IDS switch provides a voltage and current and can monitor the opening
and closing of a dry contact switch.
To connect the digital input;
1. Ensure the power source is off prior to connection.
2. Strip 2x12-20AWG (3.31 mm² -0.52 mm²) twisted pair copper wires 7-8 mm.
3. Loosen the terminal block screws and connect wires into the terminals.