MANUAL PERIBEST I12
–
I17
–
I21
23 | 29
lifetime of
the hoses
High pump speed
Reduce pump speed
High conveying temperature
Reduce product temperature
High operating pressure
Reduce operating pressure
Pump cavitation
Check the suction conditions
Abnormal
elevation
of
temperature
Check rollers shaft mounting
Unsuitable lubricant
Use original lubricant
Insufficient level of lubricant
Add original lubricant
Pump hose
pulled into
the pump
housing
High inlet pressure (> 3 bar)
Reduce inlet pressure
Pump hose filled with solidss
Clean or replace the pump hose
Press
flanges
insufficiently
tightened
Re-tighten press flanges
Insufficient lubricant
Add original lubricant
The pump
does
not
start up
Insufficient motor performance
Check motor and replace if necessary
Insufficient
output
from
frequency converter
The frequency converter must match
the motor
Blockage in the pump
Check if the suction or discharge side is
blocked. Rectify blockage