47
Technical Data
SONO WZ
Translation of the Original Instructions for Use
Power supply:
7 V – 24 V DC
Current consumption:
150 mA with 12 V/DC during 2 – 3 s measuring cycle time
Measurement range:
0 – 100 % water content
Repeatability accuracy of water con-
tent measurement (with stationary
probe in concrete):
±2 l/m³
Absolute accuracy:
± 3 % of the amount of water
Conductivity range:
0 – 40 dS/m
Measuring volume:
0.5 l
Temperature range of probe:
0 °C – 50 °C
Calibration:
Calibration for fresh concrete pre-installed
Self-calibration is possible, storage capacity for up to 15 calibration
curves
Protection type for probe:
Waterproof encapsulated in Protection Class IP67
Probe dimensions:
155 x 60 mm
Interfaces:
1.5-m cable with 7-pin coupling socket
Lancehead-Shaped Probe