Adjusting and Measuring
SONO WZ
Translation of the Original Instructions for Use
Smileys in the display show if the stand-
ard deviation is good (<0.2), acceptable
(0.2....0.49) or not acceptable (>0.5).
The hand-held measuring instrument au-
tomatically filters out measurement re-
sults of water content values that are
<100 l. This could happen, for example, if
the start button is accidentally pressed
during a series of measurements or if the
probe was not completely submerged in
the concrete. These measured values
(<100 l) are indicated through a warning
sign and are not used for calculating
the average value!
By pressing the button, the series of
measurements can be deleted and the
SONO WZ is then ready for a new meas-
uring cycle.