44
Tables and Formulations
SONO WZ
Translation of the Original Instructions for Use
With the adjustment of the two parame-
ters CHAR (fine, coarse, normal, special)
and G-Set (core water and additive), rela-
tively good conformity of the SONO WZ
results with verified actual values or tar-
get values can probably be guaranteed.
In order to achieve the best possible accu-
racy of the SONO WZ, we recommend
archiving the settings required for the
measurements while repeatedly checking
the different types of concrete.
The following example table shows one
possibility of archiving.
Type of concrete or
type no.
Target bulk density
value
CHAR parameters
G-Set parameters
F600TL
2.422
coarse
-10
AAV2
2.441
normal
-5
163802
2.330
normal
-8
3716CL
2.367
fine
-5
Formulation Management and Archiving