ION/CME N-Series Digital Drive Developer Kit User Manual
2
selected. The programmed baud rate should match the baud rate entered into the N-Series IONs, the protocol should
be programmed to multi-drop, and the correct address/node ID should be entered.
With the full network powered on, If RS485 communication is successful, an additional set of graphical icons
representing each of the N-Series IONs on the network will be loaded into the Project window. If communication is
not successful, after about 2 seconds a Communications Timeout Error dialog box appears. If this happens, recheck
your connections, and retry to establish communications with the ION units.
If RS485 communications are functioning properly, the last step is to disconnect the Serial3 programming port.
Instructions to do this can be found at
Section 2.2.4, “Disconnecting Serial3 Programming Port Communications.”
RS485 communication setup is now complete and you are ready to execute all Pro-Motion and N-Series ION
functions via RS485 network.
2.3
Activating Ethernet
Communications
N-Series IONs of Ethernet host interface type support 100 Base-T Ethernet Communications. For detailed
information on N-Series ION’s Ethernet interface, refer to
ION/CME N-Series Digital Drive User Manual
.
2.3.1
Setting Up the ION For Ethernet
Communications
Here is the Pro-Motion sequence used to set up the N-Series ION to connect via its Ethernet host interface.
1
With serial communications via the 3-pin programming cable functioning properly, click the Device
toolbar button. The Device window appears.
2
Click Network I/O. The Network I/O Defaults dialog box appears.
3
Click the Ethernet tab. This window appears with data entry fields for the IP Address, the Net Mask, and
the gateway. This is shown below with default values visible.
4
Enter the IP Address in the corresponding data field as well as the net mask and gateway if this is required
for your network.
For a typical installation you will not change the netmask and gateway default values, but you must specify a valid,
unique IP Address. If you are not sure what IP addresses are free and available for your Ethernet network contact
your system administrator.
Содержание CME N Series
Страница 6: ...vi ION CME N Series Digital Drive Developer Kit User Manual ...
Страница 8: ...viii ION CME N Series Digital Drive Developer Kit User Manual ...
Страница 30: ...30 ION CME N Series Digital Drive Developer Kit User Manual 1 ...
Страница 58: ...58 ION CME N Series Digital Drive Developer Kit User Manual 3 7 6 7 6 PP LQFK ...
Страница 69: ...ION CME N Series Digital Drive Developer Kit User Manual 69 4 ...
Страница 70: ...70 ION CME N Series Digital Drive Developer Kit User Manual 4 ...