Each fixture takes up 5 DMX Channels (See Above)

You have a cable from the controller to the first fixture cable, then from first to second and so on.  The last

light then has a DMX terminator plugged in.

Fixture 1 would be set to DMX address 1 

Fixture 2 would be set to DMX address 6

Fixture 3 would be set to DMX address 11

Fixture 4 would be set to DMX address 16

When setting these addresses, ensure that the fixture addresses dont overlap. You can set two fixtures to the

same address as long as they have the same channel layout, they will then perform in the same way.

We recommend you to read manuals for your DMX fixture and controller in full.  Some controllers tell you

what each fixture address needs to be, and some equipment will need other settings changed before they will

work.

Содержание Fog Blaster 3000

Страница 1: ...NOT OPEN RISQUE D ELECTROCUTION NE PAS OUVRIR STROMSCHLAGGEFAHR NICHT OFFNEN In Compliance with the following directives RoHS Directive 2002 95 EU and WEEE directive 2002 96 EU If this product is no longer functional or reached the end of its usable life please take it to an approved recycling plant ...

Страница 2: ... to a mains socket with suitable trip and RCD protection To disconnect from the mains socket always remove by the mains plug Do not attempt to remove by pulling the mains cable Disconnect the unit from the mains supply before cleaning Cleaning should be carried out with a soft dry cloth Do not submerge or expose this machine to any liquid Do not operate near exposed water or in high humidity Choos...

Страница 3: ...he heater Never aim the nozzle directly at people Use only in a well ventilated area do not cover the machine vents In order to guarantee adequate ventilation allow a free air space of at least 20cm around all sides of the machine Effects fluids can cause irratation and injury handle with care and keep out of the reach of children Avoid contact with the eyes and skin if this occurs rinse with warm...

Страница 4: ...controller or previous DMX fixture 5 DMX Output Male 3 pin used to connect to next DMX fixture in the chain 6 Power Switch Used to turn the smoke machine on and off 7 Circuit Breaker If this trips reset once if it trips again there may be a problem with the machine 8 Mains Input Plug the supplied PowerCon mains cable in here 9 Remote Control For connection of the wireless receiver 10 Menu Button u...

Страница 5: ...n put any body part close to the heater output Unscrew the Lid on the fluid bottle fill up with a suitable fog liquid make sure not to over fil Then screw the plastic cap back on Make sure the tank never runs dry during operation Connect the PFX3000S to a suitable mains supply There is a simple 4 button menu with LCD display on the back of the unit the 4 buttons control menu up down and enter When...

Страница 6: ...ring rigging de rigging and servicing Locate the smoke machine in a well ventilated area away from flammable materials and liquids The smoke machine needs to be 50cm away from surrounding walls and fixtures The smoke machine should be installed out of reach of people and not where people are seated walking or standing When mounting make sure the installation point can take the weight Make sure a s...

Страница 7: ...ntroller This is normally done by a digital display panel where the address can be changed by simple up and down buttons the address ranges from 1 512 Alternatively it may be controlled by a row of small switches called dip switches on this type system the required address is then converted to a binary number DMX Connector Wiring 3 Pin wiring is more common but the 5 pin configuration is often use...

Страница 8: ...would be set to DMX address 11 Fixture 4 would be set to DMX address 16 When setting these addresses ensure that the fixture addresses dont overlap You can set two fixtures to the same address as long as they have the same channel layout they will then perform in the same way We recommend you to read manuals for your DMX fixture and controller in full Some controllers tell you what each fixture ad...