background image

NOTE:

 

All the illustrations in this manual are for explanation and reference purposes only. 

            Unit purchased may be slightly different.

The design and specifications are subject to change without prior notice for product 

improvement. Contact customer service for details.

1

SAFETY PRECAUTIONS ..................................................................................... 2

IMPORTANT SAFETY INSTRUCTIONS ...............................................................4

AIR CONDITIONER FEATURES.......................................................................... 5

CONTROL PANEL OPERATION .........................................................................4

DIP SWITCH CONFIGURATION .......................................................................... 7

INSTALLATION ...................................................................................................10

CARE AND CLEANING...................................................................................... 12

TROUBLESHOOTING TIPS ............................................................................... 13

This manual provides the information needed for proper use and maintenance of this air 

conditioner. Basic preventative care can help extend the life of this unit. The “Troubleshooting 

Tips” section in this manual contains a chart with solutions to the most common problems. 

Referring to this section may save time and prevent the need for a service call in the event of 

a problem.

!

CAUTION

● Contact an authorized service technician for installation, repair or maintenance of this unit.

● If power cord is damaged and requires replacement, the work should be performed by 

authorized service personnel only.

● Installation and repair work must be performed in accordance with national wiring standards 

by authorized personnel only.

● Do not operate your air conditioner in a room such as a bathroom or laundry room where 

direct or indirect exposure to water is possible.

● All units have a heating function and must be at least 3 1/2 ft (1 meter) away from  

combustible and flammable materials.

● The air conditioner is not intended for use by young children without supervision. 

Young children should be supervised to ensure that they do not play with the air conditioner.

● Disabled persons may require assistance with set up.

CONTENTS

Содержание 1PTC07A-3.5

Страница 1: ...read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort PACKAGED TERMINAL AIR CONDITIONER USER MANUAL FOR MODELS 1PTC07A 3 5 1PTC09A 3 5 1PTC12...

Страница 2: ...ferring to this section may save time and prevent the need for a service call in the event of a problem CAUTION Contact an authorized service technician for installation repair or maintenance of this...

Страница 3: ...may cause fire Failure to do so may cause explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of mach...

Страница 4: ...main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified serviced technic...

Страница 5: ...age within the airconditioner Do not use an extension cord or an adaptor plug WARNING DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance A...

Страница 6: ...LED for POWER indicates the unit s ON OFF status If the unit is in ON mode the LED will be green If the unit is OFF the LED will be off Note HEAT mode is for models with Cooling Heating functions only...

Страница 7: ...ature of the unit in cooling or heating mode The temperature can be set by increments of 1 F 1 C The temperature setting appears in the display NOTE Press and hold the and buttons together for 3 secon...

Страница 8: ...e in continuous or cycle mode while the unit is in heating and cooling mode CON Continuous Allows the fan to run continuously circulating air even when the temperature setting has been satisfied This...

Страница 9: ...sal wall thermostat WALL THERMOSTAT TERMINAL INSTALLATION OF WALL THERMOSTAT PROVIDED BY THE AIR CONDITIONER S MANUFACTURER NOTE When installing a thermostat provided by the air conditioner s maufactu...

Страница 10: ...k If High fan is desired wire the G output from the thermostat to HI FAN on the unit s terminal block The range of set temperature of the wall thermostat must be in accordance with the unit type heat...

Страница 11: ...reme care should be used to avoid serious cuts The air conditioner is heavy Always use 2 people when lifting or moving unit COOLED AIR INTAKE AIR WALL WALL HEAT RADIATION SLEEVE Over 20 Fig 2 Fig 3 Fi...

Страница 12: ...holes See Fig 7 and Fig 8 Reinstall front panel See Fig 9 Place tabs over top rail Push Inward at bottom until panel snaps into place NOTE When vent control lever set at CLOSED only the air inside the...

Страница 13: ...e or with damaged filter will allow dirt and dust to reach indoor coil and reduce cooling heating airflow and efficiency of unit Airflow restriction may cause damage to unit Do not UNIT DAMAGE HAZARD...

Страница 14: ...ately 3 minutes for compressor to start Strange numbers characters appear on the display The unit may be in a protection mode The unit may be set for C instead of F The unit is making noises Clicking...

Страница 15: ...Printed in PRC...

Отзывы: