HOW TO INSTALL THE UNIT

- For an existing wall sleeve, measure the sleeve’s

dimensions.

- Installation of the air conditioner according to these

instructions will assure the unit’s best performance.

All wall sleeves used to mount the new air conditioner

must be in good structural condition and have a rear

grille that securely attaches to the sleeve or the flange

of the sleeve to secure the new air conditioner.

- To avoid vibration and noise,make sure the unit is

installed securely and firmly.

- When installing the sleeve,make certain there is

nothing within 20" of the back that would interfere

with heat radiation and exhaust air flow. (See Fig. 2.)

!

CAUTION

There are sharp edges and extreme care should

be used to avoid serious cuts.

The air conditioner is heavy. Always use 2 people

when lifting or moving unit.

COOLED

AIR

INTAKE

AIR

WALL

WALL

HEAT

RADIATION

SLEEVE

Over 20

Fig. 2

Fig. 3

Fig. 4

Fig. 5

PREPARATION OF SLEEVE ASSEMBLY (optional)

- Refer to the installation instruction of sleeve assembly

for details.

UNIT INSTALLATION

- Carefully remove shipping tape from the front panel.

(See Fig. 3)

Shipping

tape

- Remove the shipping screw from the vent door. (See

Fig. 5)

- Remove the front panel. (See Fig. 4)

Shipping

screw

1067mm/42inch

408mm/16inch

606mm/23.9inch

Fig. 1a - Dimensions of Air Conditioner

376mm/14.8inch

408mm/16inch

1067mm/42inch

Fig. 1b - Dimensions of Sleeve 

 

 Assembly (optional)

-

Pull out at the bottom to release it from

the tab     .

- Then lift up     .

PREPARATION OF REAR GRILLE ASSEMBLY (optional)

- Refer to the installation instruction of rear grille

assembly for details.

INSTALLATION

Содержание 1PTC07A-3.5

Страница 1: ...read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort PACKAGED TERMINAL AIR CONDITIONER USER MANUAL FOR MODELS 1PTC07A 3 5 1PTC09A 3 5 1PTC12...

Страница 2: ...ferring to this section may save time and prevent the need for a service call in the event of a problem CAUTION Contact an authorized service technician for installation repair or maintenance of this...

Страница 3: ...may cause fire Failure to do so may cause explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of mach...

Страница 4: ...main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified serviced technic...

Страница 5: ...age within the airconditioner Do not use an extension cord or an adaptor plug WARNING DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance A...

Страница 6: ...LED for POWER indicates the unit s ON OFF status If the unit is in ON mode the LED will be green If the unit is OFF the LED will be off Note HEAT mode is for models with Cooling Heating functions only...

Страница 7: ...ature of the unit in cooling or heating mode The temperature can be set by increments of 1 F 1 C The temperature setting appears in the display NOTE Press and hold the and buttons together for 3 secon...

Страница 8: ...e in continuous or cycle mode while the unit is in heating and cooling mode CON Continuous Allows the fan to run continuously circulating air even when the temperature setting has been satisfied This...

Страница 9: ...sal wall thermostat WALL THERMOSTAT TERMINAL INSTALLATION OF WALL THERMOSTAT PROVIDED BY THE AIR CONDITIONER S MANUFACTURER NOTE When installing a thermostat provided by the air conditioner s maufactu...

Страница 10: ...k If High fan is desired wire the G output from the thermostat to HI FAN on the unit s terminal block The range of set temperature of the wall thermostat must be in accordance with the unit type heat...

Страница 11: ...reme care should be used to avoid serious cuts The air conditioner is heavy Always use 2 people when lifting or moving unit COOLED AIR INTAKE AIR WALL WALL HEAT RADIATION SLEEVE Over 20 Fig 2 Fig 3 Fi...

Страница 12: ...holes See Fig 7 and Fig 8 Reinstall front panel See Fig 9 Place tabs over top rail Push Inward at bottom until panel snaps into place NOTE When vent control lever set at CLOSED only the air inside the...

Страница 13: ...e or with damaged filter will allow dirt and dust to reach indoor coil and reduce cooling heating airflow and efficiency of unit Airflow restriction may cause damage to unit Do not UNIT DAMAGE HAZARD...

Страница 14: ...ately 3 minutes for compressor to start Strange numbers characters appear on the display The unit may be in a protection mode The unit may be set for C instead of F The unit is making noises Clicking...

Страница 15: ...Printed in PRC...

Отзывы: