Continuous Drainage
•
Pull out the rubber plug from the drain tube.
•
Connect the drain hose to the tube and lead the hose to a proper collecting basin. Make sure never to
crimp the drain hose.
7. Troubleshooting
Problem
Possible Cause
Solution
Unit does not work
Power supply fault
•
Power plug not connected
•
Defective power plug or cord
•
Defective fuse
•
Plug in correctly
•
Replace power plug or cord
•
Replace the fuse
Unit stops running
automatically
Timer has elapsed or environmental
temperature is cooler than set
temperature
Disable the timer function or start
manually
No cool air when running under
cooling mode
•
Timer has elapsed or
environmental temperature is
cooler than set temperature
•
Evaporator is covered with frost
•
Disable the timer function or start
manually
•
Unit is defrosting. Unit will restart
after defrosting period
No cool air when running under
dehumidifying mode
Evaporator is covered with frost and
unit is defrosting
Unit is defrosting. Unit will restart
after defrosting period
Error code E3 displayed
Air exhaust pipe is defective
Replace the air exhaust pipe
Error code E4 displayed
Water storage tank is full
Drain the water storage tank
8. Technical Specifications
Power Supply
max. 240VAC / 50Hz
Power Consumption
max. 1200W
Fuse
3.15A / 250V
Cooling Power
3200W
Cooling Capacity
12 000 BTU/h
Airflow
350m³/h
Humidity Extraction
1.5l/h
Noise
< 52dB (A)
Length of Connection
1.8m
Dimensions
Indoor Unit
870 x 445 x 400mm
Outdoor Unit
535 x 485 x 200mm
Weight
Indoor Unit
42kg
Outdoor Unit
10kg
For more info concerning this product, please visit our website www.perel.be