18
8
Hydraulic diagrams
Shown hydraulic schemes do not replace the design of central heating and may be used
only for informational purposes.
Diagram with 4-way control valve for central heating circuit
3
, where: 1
–
boiler, 2
–
ecoMAXX
regulator
–
module A, 3
–
ecoMAXX regulator
–
control panel, 4
–
fan, 5
–
feeder temperature sensor, 6 -
gear-motor, 7
–
boiler temperature sensor, 8
–
HUW temperature sensor, 9 - mixer temperature sensor, 10
–
temperature (weather) sensor 12
–
HUW circuit pump, 13
–
mixer circuit pump, 14
–
electric servo the
valve, 15
–
HUW container, 16
–
room thermostat or ecoSTER200, 17
–
HUW circulating pump, 27
–
return
temperature sensor (does not affect combustion process control), P
–
electric relay.
As there is not mechanically forced water flow in boiler return circuit - this method of protection of
boiler return circuit from cold water is not efficient. Use of other methods is recommended. To
improve water flow in gravitational circuit of the boiler (the circuit is indicated on the diagram with
a bold line) it is necessary to: (i) use pipes and 4-way valve of large DN value, (ii) avoid using
excessive number of elbows and cross section reductions, and (iii) apply other rules of gravitational
circuit construction - e.g. keeping of gradients, etc. In case the return temperature sensor is of
contact type - provide the sensor with heat insulation to isolate it from the environment and
improve its thermal contact with the pipe by application of thermal paste. Set the preset boiler
temperature at so high value that heat output required to the heating circuit and to heat-up return
water to the boiler is guaranteed.
RECOMMENDED SETTINGS:
Parameter
Setting
MENU
OPERATION mode:
Return Protection
ON
Service Settings Boiler Settings Return
Protection 4D
Min. return temp
45 C
Return temp. hyst.
2 C
Valve closing
0%
Min. preset boiler temperature
70 C
Service Settings Boiler Settings
Mixer support 1
ON CO
Service Settings Mixer Settings 1
Max. preset temperature of mixer 1
75
Service Settings Mixer Settings 1
Heating curve. mixer 1
0.8
–
1.4
Service Settings Mixer Settings 1
Weather control mix.1
ON
Menu Mixer Settings 1
Output H
Circulating
Pump
Menu Service Settings
Circulation support
ON
Menu Pump Service Settings
3
The presented hydraulic diagram does not replace central heating engineering design and may be used for information
purposes only.
Содержание KSP Duo
Страница 1: ...Operation and maintenance manual for the boilers with feeder KSP Duo...
Страница 22: ......
Страница 23: ......
Страница 26: ......
Страница 31: ...REGULATOR INSTRUCTION MANUAL ecoMAX 910R1...
Страница 41: ...USER MANUAL OF CONTROLLER INSTALLATION AND SERVICE SETTINGS ecoMAX 910R1...
Страница 47: ...23...
Страница 71: ...47...
Страница 73: ...Quatro PSQ SCREW CONVEYOR FEEDER U S E R S MA N UA L Updated user s manual are available at www pereko pl...
Страница 82: ......
Страница 84: ...wer 13 12 2017 r...