![Pereko KSP Duo Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/pereko/ksp-duo/ksp-duo_operation-and-maintenance-manual_1528311033.webp)
9
7.3
Setting
the
preset
boiler
temperature
Set the preset boiler temperature in:
MENU Boiler settings
Preset boiler
temperature
Note: Preset boiler temperature will be
automatically increased to enable filling HUW
container and heating circuits of mixers, if
required.
7.4
STOP
Upon start-up the regulator remains in STOP
mode. To activate STOP mode press the
knob on main screen.
Upon activation of STOP mode, the boiler
burner is OFF, while hydraulic system
remains in normal operation.
7.5
FIRING UP
To activate FIRING-UP mode - press the
knob and select FIRING-UP. This mode
enables to control manually fan and fuel
feeder. Follow strictly the instructions of the
boiler manufacturer when firing-up the
boiler.
The feeder starts once the knob has been
pressed on a feeder symbol. Feed such
amount of fuel so that it appears at the end
of retort. Press the knob again to stop the
feeder, and put firelighter (e.g. barbecue
kindling-fuel) below the fuel layer and fire it.
Press the knob once on a fan symbol to start
the fan and press again to stop it. Fire the
fuel supplied, and feed next fuel dose, if
required.
Manual feeder start-up
Once you have made sure fire in the furnace
is properly kindled - stop the fan and the
feeder and press EXIT to leave FIRING-UP
mode. Now, the regulator enters OPERATION
mode and the word OPERATION appears in
the left upper corner. Regulator starts to
work in automatic cycle.
If the user does not switch-over the
regulator to OPERATION mode, the
regulator will heat-up the boiler to
preset temperature
+ 10 C, and will
automatically enter OPERATION
mode,
and
subsequently
SUPERVISION because the preset
boiler
temperature
has
been
reached.
In case actual boiler temperature is
higher than
its preset value
+ 10 C,
FIRING -UP mode is inaccessible.
In such a case wait until the boiler
cools down.
7.6
OPERATION
–
STANDARD mode
The regulator offers two modes of boiler
burner control:
-
Standard
mode
–
without output
modulation (described in this chapter),
-
Fuzzy logic
mode - with output
modulation
1
.
To activate
Standard
mode - click:
MENU
Boiler Settings
Burner Settings
Regulation mode
and Standard. This option
1
Fuzzy Logic mode of regulator operation has to be
activated - see sec. 21.1
Содержание KSP Duo
Страница 1: ...Operation and maintenance manual for the boilers with feeder KSP Duo...
Страница 22: ......
Страница 23: ......
Страница 26: ......
Страница 31: ...REGULATOR INSTRUCTION MANUAL ecoMAX 910R1...
Страница 41: ...USER MANUAL OF CONTROLLER INSTALLATION AND SERVICE SETTINGS ecoMAX 910R1...
Страница 47: ...23...
Страница 71: ...47...
Страница 73: ...Quatro PSQ SCREW CONVEYOR FEEDER U S E R S MA N UA L Updated user s manual are available at www pereko pl...
Страница 82: ......
Страница 84: ...wer 13 12 2017 r...