background image

TTD-08A Electromechanical Box Tripod Turnstile 

13 

The control mode is set by removal / installation of the jumper on a J1 connector on control 
board. The J1 connector location is shown in Fig.  5.  An installed jumper corresponds to 
the pulse control mode. In order to switch to potential mode, uninstall the jumper. The 
change of control mode will take place after switching on the turnstile. 

Pulse control mode 

The mode is used to control the turnstile with RC panel, WRC and CLB, outputs of which 
support pulse control mode.  

Duration of control signal during command issuing on operational control inputs should be 
not less than 100mc. The passage waiting time is 5 seconds and it doesn’t depend on 
duration of control signal (impulse). 

Description of turnstile work in pulse control mode is described in Table 5  Procedure of 
command issuing is described in Appendix 1.  

By removal of low-level signal from special control input 

Fire Alarm

, turnstile switches to 

Fire Alarm,

  mode and therewith all incoming commands of turnstile control are ignored 

(see Clause 5.3.2). 

During low-level signal issuing at the input 

Fire Alarm

 command 

«Passage Denial» 

is sent 

and turnstile rotary mechanism is blocked.  

Potential control mode 

The mode is used to control the turnstile with CLB, outputs of which support  potential 
control mode.  

Duration of control signal during command issuing on operational control inputs should be 
not less than 100mc.  

The passage waiting time equals the duration of control signal: if by the moment of the 
passage in authorized direction at the entrance of this direction there is a low-level signal, 
then the turnstile will stay open in this direction.  

At the low-level signal inputting to the “Stop” input, both directions will lock for the time of 
the signal duration regardless of the signal strength at the inputs “Unlock A” and “Unlock 
B”. By the removal of a low-level signal from the “Stop” input, the directions will set to the 
modes according to the signal strength at the inputs “Unlock A” and “Unlock B”. 

Description of turnstile work in potential control mode is described in Table 6. Procedure of 
command issuing is described in Appendix 2. 

 

Note: 

To organize single passages in potential control mode it is advisable to remove low-
level control signal from control input 

Unlock A

Unlock B

  during activation of relay 

output 

PASS A / PASS B

 of corresponding direction. 

5.2.7 

Algorithm of the control mechanism 

Procedure of turnstile work in the pulse control mode in case of a single passage in one of 
directions: 

1.  From control unit (RC panel, WRC, ACS) on control board inputs comes a 

command (combination of control commands) for execution of a single passage in 
one of directions. 

2.  Microcontroller, fixed on the control board, processes the received signal 

combination and forms a command to the turnstile control unit to unblock the rotary 
mechanism. Turnstiles hold time counting starts in the blocked mode. 

3.  Control mechanism unlocks the rotary mechanism for the rotation in a chosen 

direction. Passage in this direction becomes possible. 

Содержание TTD-08A

Страница 1: ......

Страница 2: ...Electromechanical Box Tripod Turnstile with Automatic Anti Panic Arms TTD 08A Assembly and Operation Manual ...

Страница 3: ...stile 16 5 4 1 Relay outputs 16 5 4 2 ID and siren 17 5 4 3 Remote indicators 17 5 5 Operation contingencies and response 18 6 MARKING AND PACKAGING 19 7 SAFETY REQUIREMENTS 20 7 1 Installation safety requirements 20 7 2 Operation safety requirements 20 8 INSTALLATION INSTRUCTIONS 21 8 1 Installation details 21 8 2 Installation tools 23 8 3 Length of cables 23 8 4 Connection layout of the turnstil...

Страница 4: ...ION The TTD 08A electromechanical box tripod turnstile with automatic anti panic folding arms hereinafter the turnstile is designed for managing pedestrian flows at entrance points of industrial facilities banks administrative buildings retail outlets railway terminals airports providing free passageway in emergency situations Housing of the turnstile is made of stainless steel Outdoor application...

Страница 5: ...le length 2 Ingress Protection Rating IP44 EN 60529 min 6 6 m Electric shock protection class III IEC 61140 Mean time to failure min 1 500 000 passages Mean lifetime 8 years Overall dimensions L W H 1166 750 1016 mm Net weight of the turnstile max 70 kg Figure 1 Overall dimensions of the TTD 08A turnstile 1 The power consumption can rise to 72W within 5 sec after power up or at taking off the Fire...

Страница 6: ...adhesive cable tie mount 3 Nylon cable tie 100 mm 6 Self adhesive PCB pillars FSS 5 4 Technical documentation Certificate 1 Assembly and operation manual 1 Package Box 1 4 2 Optional equipment supplied on request Power supply unit 1 WRC kit 12VDC 6A 1 2 SORMAT anchor PFG IR 10 15 4 1 1 The power supply source must have load current min 6A within 5 sec 2 WRC kit consists of a receiver and transmitt...

Страница 7: ...rnstile has relay outputs for connection of an intrusion detector and a siren There are two modes for the turnstile control a pulse control mode and a potential control mode After each passage the turnstile provides automatic complete rotation of the barrier arm to home position i e automatic reset After the turn of barrier arm for more than 60º angle its reverse rotation is blocked Smoothness of ...

Страница 8: ...nel with cable Not included in the standard delivery set 13 power cable 14 emergency opening device Fire Alarm cable 15 ACS connection cable 5 2 1 Turnstile housing Internal elements of the turnstile housing are accessed through the removable top cover 3 Fastening of the cap to the housing is accomplished with the help of driver screw 4 During operation of the turnstile top cover has to be locked ...

Страница 9: ...cy opening of the passageway 5 2 2 Indication modules To inform about a current status and a set module of the turnstile work both front sides of the turnstile housing feature indication modules see Fig 3 The indication module has 3 mnemonic indicators green indicator of authorized passage arrow red indicator of passage denial cross white indicator showing the card presentation spot Figure 3 Indic...

Страница 10: ...4 5 green indicators Left Right 6 red indicator Stop 7 RC cable 5 2 4 Control Logic Board Turnstile control board see Fig 5 and remote connector block XS1 are fixed on the bracket located inside the post To access the board it is necessary to remove the turnstile cover following the instructions of Clause 6 Figure 5 Control Logic Board CLB ...

Страница 11: ...7 Pass B PASS A relay contact passage in direction B 9 Ready Relay output READY turnstile readiness 10 Det Out Relay output DET OUT retransmission of intrusion detector condition XT3 12VDC 1 12V Connection of external power supply 2 GND XT4 Light A 1 NO Light A relay contacts connection of remote indicator for direction A 2 C 3 NC XT5 Light B 5 NO Light B relay contacts connection of remote indica...

Страница 12: ...ial control mode The jumper is fixed at the factory before the delivery see Clause 5 2 6 J2 connector for programming Power power LED indicator on the control board For convenience connection contacts of turnstile power supply and turnstile control units are set on the bracket on connector block XS1 Connection is conducted out in accordance to the connection diagram of the turnstile and optional e...

Страница 13: ...ce with the resistance of the connected cable no more than 300 Ohm the circuit with open collector output as the control element voltage at the closed contact low level signal at the CLB input no more than 0 8 V 5 2 6 Control modes of the turnstile There can be two control modes of the turnstile pulse and potential In both modes turnstile control is conducted by command issuing namely by combinati...

Страница 14: ...0mc The passage waiting time equals the duration of control signal if by the moment of the passage in authorized direction at the entrance of this direction there is a low level signal then the turnstile will stay open in this direction At the low level signal inputting to the Stop input both directions will lock for the time of the signal duration regardless of the signal strength at the inputs U...

Страница 15: ...s in unblocked mode 5 seconds from receiving the instruction by default 7 Turnstile is ready for next passage 5 3 Control devices of the turnstile The turnstile can be operated from the following control devices the RC panel the WRC the ACS controller The above devices can be connected to the turnstile as follows any device separately in any combination with each other all devices simultaneously i...

Страница 16: ...uring release of control signal on Fire Alarm input turnstile switches to the emergency Fire Alarm passageway opening In this mode all incoming turnstile control signals are disregarded Turnstile rotation mechanism is blocked for rotation in both directions Central barrier arm falls down automatically by gravity and takes a vertical position which opens the passageway The following indication in b...

Страница 17: ...e Clause 5 4 2 Contacts Pass A Pass B and Common are also located on connector block XS1 Relays have normally open contacts Therewith common for those relays contact Common is not connected with the negative of turnstile power supply galvanically isolated In initial standard condition with a switched on power supply relay contacts PASS A PASS B READY and DETECTOR are closed relay coil gets energiz...

Страница 18: ...e Control signal from intrusion detector doesn t lead to ALARM output activation if the rotating mechanism of the turnstile is blocked in one of directions or was blocked less than 3 seconds ago 5 4 3 Remote indicators Remote indication blocks for corresponding passage directions is connected to outputs Light A and Light B Outputs are provided with the complete group of contacts normally opened NO...

Страница 19: ...arrier arms without a command to unblock the rotation unit Barrier arms return to initial position is considered to be delayed if the passage zone is opened for more than 30 seconds In each of indicated cases the activation of switch READY takes place switch coil is deenergized therewith the output contacts Ready and Common get opened ref Section 5 4 1 When barrier arms reset to home position norm...

Страница 20: ...f the turnstile housing use it to unscrew the drag screw 4 unlocking the top cover 3 Holding the front edge of the top cover 3 carefully lift it and turning it remove it from the turnstile housing Be careful not to damage the CLB located under the cover while removing the top cover 4 Place the top cover on a flat steady surface Installation of the top cover back into its operation position is carr...

Страница 21: ...e turnstile first power on make sure its installation and connection have been made accordingly Power supply unit installation must be made in accordance with the safety rules stipulated in its certificate 7 2 Operation safety requirements Observe general electrical safety rules when operating the turnstile Warning Do not use the turnstile under conditions that do not comply with the requirements ...

Страница 22: ... 200 mm for installation on less steady foundation to mark the mounting holes according to Fig 14 to control vertical alignment of the turnstile with a level during installation to do installation of the turnstile by at least 2 skilled installers when arranging a passage area through the turnstile please take into account that the resetting mechanism operates as follows at the barrier arm turning ...

Страница 23: ...ailing ref Section 9 4 can serve as such an exit Figure 12 Cable layout inside the housing 1 CLB 2 indication module IM1 3 indication module IM2 4 remote connector block XS1 5 power cable 6 cable from the RC panel WRC device 7 indication cable 3 on Fig 13 8 intermediate indication cable from IM1 to IM2 6 on Fig 13 9 bracket for reader installation 10 ACS installation zone ...

Страница 24: ...nt in use ensures the required parameters and measurement accuracy 8 3 Length of cables Cables used for installation are listed in table 3 Table 3 Cables used during the installation Equipment connected to the turnstile controller Maximum cable length m Cable type Minimum cross section mm Example of the cable 1 Power supply 10 Twin wire 1 5 AWG 18 HO3VV F 2 1 5 bi colored 20 Twin wire 2 5 AWG 13 H...

Страница 25: ...layout of the turnstile and optional equipment Figure 13 Connection layout of the TTD 08A turnstile and optional equipment 1 1 Elements of the scheme are listed in Table 4 Elements marked with a star sign are not included in standard delivery set ...

Страница 26: ... logic board CLB 140 1 A6 RC panel 1 A7 1 WRC device 1 A81 ACS controller 1 A91 Turnstile power supply DC 12V 1 A101 Intrusion detector 1 A111 Siren DC12V 1 A121 Emergency opening device Fire Alarm 1 A13 11 A13 21 Remote indicators 2 A141 Remote indicator power supply 1 XS1 Remote connector block Klemsan 1 12 2 1 Cable power of the CLB 1 2 Control cable 1 3 Indication cable 1 4 5 Cables of directi...

Страница 27: ...ply unit 3 Drill the holes for anchor bolt sleeves to fix the turnstile housing Ref Fig 14 4 If you lay the cables under the floor surface prepare the electric raceway to the cables laying zone of the turnstile housing The cables layout inside the turnstile housing is shown in Fig 12 Caution It is necessary to leave a reserve of length enough for hinged joint removal and for the access to the barr...

Страница 28: ...d install card readers on specially provided for it brackets on the housing flanks 9 in Fig 12 To ease the installation procedure remove the bracket by loosening two nuts M3 with an open end wrench S5 5 located below under the bracket To connect card readers use free contacts 15 24 of the remote connector block XS1 Attention Possibility of PERCo card reader s installation is anticipated in the tur...

Страница 29: ...o 50 sec Put your hand before the intrusion detector The continuous signal will sound when the intrusion detector activates To eliminate that sound signal press any button on the RC panel The sound will stop without pressing the button in 5 sec The turnstile is ready for operation 9 2 Operating modes of the turnstile at pulse control mode See Table 5 for the operating modes set from the RC panel a...

Страница 30: ...pleted passage Free passage in the set direction open for free passage in the chosen direction Press the STOP button and the button corresponding to the chosen passage direction LEFT RIGHT simultaneously The green indicator above the button of the chosen passage direction Left Right is on The Green arrow in the chosen passage direction is on Turnstile remains open in the set direction Free passage...

Страница 31: ...rection are on The turnstile is locked One of the passage directions is open the turnstile is open for passage in the set direction The low level on the contact corresponding to the passage direction the high levels on the other contacts The green indicator above the button of the chosen passage direction Left Right is on The Green arrow in the chosen passage direction is on When the passage is co...

Страница 32: ... Check the power cable serviceability and reliability of its connection to the CLB XS1 and XT3 connector blocks The turnstile is not controlled in one of the directions and there is light indication on the turnstile housing and on the RC panel The CLB does not receive a control signal for this direction Switch off the turnstile power supply from the AC mains open the turnstile housing cover and re...

Страница 33: ...ose unscrew 6 screws 3 on Fig 15 which fix the bracket on the turnstile housing and accurately take a bracket aside without damaging connected cables 4 Inspect the resetting mechanism a pusher springs and a roller optic sensors and a damper Ref Fig 16 5 Remove dust from a rotation sensor disc located in the spacing of the rotation optic sensors with alcohol gasoline blend applied with a cloth Avoi...

Страница 34: ...of the turnstile in accordance with Section 9 of this Manual After maintenance works are complete the turnstile is ready for further operation In case of any defects revealed during visual check please apply to the PERCo Technical Support Department the PERCo TSD 11 TRANSPORTATION AND STORAGE The turnstile in the original package should be transported in closed freight containers or other closed t...

Страница 35: ...eceipt the status of the passage direction A is Always free Active front is at the contact Unlock B while there is a high level at the contacts Stop and Unlock A Single passage in the direction B open for passage of one person in the direction B At this command the passage direction B opens either for 5 sec or until the passage has been effected in this direction or until the command Always locked...

Страница 36: ...low level either contacts of the output relay are closed or the output transistor is open high level either contacts of the output relay are broken or the output transistor is closed There is a high level at the contacts Unlock A and Unlock B Both directions are locked locked for entry and exit or a low level at the contact Stop Both passage directions close at this command There is a low level at...

Страница 37: ...PERCo P O Box 87 Saint Petersburg 194295 Russia Tel 7 812 321 61 72 Fax 7 812 292 36 08 E mail export perco ru support perco ru www perco com ...

Страница 38: ...www perco com export perco ru ...

Отзывы: