Table 1 – Contacts of the connector blocks
№
Item
Function of the contact
Connector blocks of the CLB.140
XT1L (In)
1
+12V
Output of power supply for ID
2 Detector Input for connections ID
3
GND
Common contact for connections ID
4 Fire Alarm
Input for emergency opening device
5
GND
6
GND
Common
7 Unlock A
Inputs for turnstile control
8
Stop
9 Unlock B
10
Led A
Indication outputs of RC panel
11 Led Stop
12
Led B
XT1H (Out)
1
GND
Output of power supply for additional devices
2
+12V
3
Alarm 1
Outputs for connections siren
4
Alarm 2
5 Common Common contact for
PASS A
,
PASS B signals
6
Pass A
PASS A
relay contact (passage in direction A)
7
Pass B
PASS A
relay contact (passage in direction B)
9
Ready
Relay output
READY
(turnstile readiness)
10 Det Out Relay output
DET
OUT
(retransmission of intrusion detector condition)
XT3 (+12VDC)
1
+12V
Connection of external power supply
2
GND
XT4 (Light A)
1
NO
Light A
relay contacts – connection of remote indicator for direction A
2
C
3
NC
XT5 (Light B)
5
NO
Light B
relay contacts – connection of remote indicator for direction B
6
C
7
NC
Out connector block XS1 on the bracket
1
+12V
Connection of external power supply
2
GND
3 Fire Alarm
Input for emergency opening device
4
GND
5
GND
Common
6 Unlock A
Inputs for turnstile control
7
Stop
8 Unlock B
9
Led A
Indication outputs of RC panel
10 Led Stop
11
Led B
12 Common Common contact for
PASS A
,
PASS B signals
13
Pass A
PASS A
relay contact (passage in direction A)
14
Pass B
PASS A
relay contact (passage in direction B)