ST-01 Speed gate, STD-01 Double-sided section
9. After the passage is completed and the swing panels are closed, the speed gate is ready for
another passage.
In potential speed gate control mode, the control signal can be released after receiving a signal
from
PASS
output for the same direction.
5.3 Operating devices
Speed gate operation can be performed through the following devices: RC-panel / WRC; ACS-
controller, Fire Alarm
device. These devices can be connected to the speed gate separately,
simultaneously or in any combination with each other.
In case several operating devices are connected simultaneously there can be a control signal
overlap. In this case speed gate will operate according to the command, generated by the signal
combination (Appendixes 1 and 2).
5.3.1 RC-panel connection
RC-panel is connected with a flexible multicore cable to
Unlock A
,
Stop
,
Unlock B
,
Led A
,
Led Stop
,
Led B, Sound
and
GND
contacts of the
X2
terminal block according to the speed gate
connection layout (Fig. 18).
Figure 12. Standard RC-panel orientation regarding speed gate sections
Note:
WRC is connected to
Unlock
A,
Stop
,
Unlock B
and
GND
contacts of the
X2
terminal block.
Power supply of the WRC is connected to
+12V
contact of the
X3
terminal block.
Standard RC-panel orientation regarding sections is stated in Fig. 12. If the operator’s workspace
is located on the opposite side regarding
Master
section, it will be more convenient to change the
RC-panel wires, which are connected to
Unlock A
and
Unlock B
contacts, as well as
Led A
and
Led B
respectively (Table 4).
Table 4. Connection of RC-panel cable wires to the X2 connector block
RC-panel orientation
№
Contact
Standard
Reverse
1
GND
black black
2
Unlock A
white green
3
Stop
blue blue
4
Unlock B
green white
5
Led A
yellow red
6
Led Stop
orange orange
7
Led B
red yellow
8
Sound
brown brown
19