background image

ASSEMBLY  AND  OPERATION  MANUAL

STD-01

Do

u

bleSided Section

ST-01

Speed Gate

Содержание ST-01

Страница 1: ...ASSEMBLY AND OPERATION MANUAL STD 01 Double Sided Section ST 01 Speed Gate ...

Страница 2: ...ST 01 Speed gate STD 01 Double sided section Assembly and Operation Manual ...

Страница 3: ...22 7 2 Operation safety requirements 23 8 INSTALLATION 23 8 1 Installation details 23 8 2 Installation tools 23 8 3 Cable length 24 8 4 Installation order 24 8 5 Mounting surface marking layouts 27 8 6 Speed gate wiring diagram 29 8 7 Training mode 30 8 8 Auto opening in the selected direction mode 31 8 9 Assembly and disassembly of the speed gate components 32 8 9 1 Central post cover plate 32 8 ...

Страница 4: ...livery set the speed gate allows to arrange one passage lane The width of the passage lane depends on the chosen swing panel width Use STD 01 double sided section hereinafter double sided section to arrange more passage lanes Each double sided section provides one extra passage lane Note Inside the turnstile sections it is possible to install access card readers as manufactured by PERCo IR03 1 MR0...

Страница 5: ...where n number of ATG 300 and ATG 300H swing panel sets installed m number of ATG 425 swing panel sets installed k number of ATG 475 swing panel sets installed Weight net ST 01 M section max 85 kg ST 01 S section max 85 kg STD 01 double sided section max 100 kg ATG 300 swing panel max 6 kg ATG 300H swing panel max 9 kg ATG 425 swing panel max 8 kg ATG 475 swing panel max 9 kg 4 DELIVERY SET 4 1 St...

Страница 6: ...for 1000 mm passageway arrangement RC panel with cable 1 in box 1 Jumper 3 in box 1 Self adhesive rubber pad with mnemonic image 2 in box 1 Installation tools Section top cover mounting kit M5 16 bolt 16 8 in each box 1 and 2 washer 5 16 8 in each box 1 and 2 Central post indication block mounting kit M5 16 bolt 4 2 in each box 1 and 2 washer 5 4 2 in each box 1 and 2 Swing panel cover plate mount...

Страница 7: ... pad with mnemonic image 2 Installation tools Section top cover mounting kit M5 16 bolt 8 washer 5 8 Central post indication block mounting kit M5 16 bolt 4 washer 5 4 Swing panel cover plate mounting kit M4 10 screw 8 washer 4 8 Swing panel mounting kit M10 30 bolt 6 M10 nut 6 washer 10 12 plastic bushing 6 Technical documentation Certificate 1 Packaging Box 1 for double sided section 1 Box for s...

Страница 8: ...ST 01 Speed gate STD 01 Double sided section Figure 1 Speed gate overall dimensions with ATG 300 swing panels Figure 2 Speed gate overall dimensions with ATG 300H swing panels 7 ...

Страница 9: ...Assembly and Operation Manual Figure 3 Speed gate overall dimensions with ATG 425 swing panels Figure 4 Speed gate overall dimensions with ATG 475 swing panels 8 ...

Страница 10: ...chosen according to the passage lane width and to the operation peculiarities upon making an order Section top covers may be chosen when ordering they can be made of tempered glass or stainless steel A wide range of optional equipment can be installed card capture reader barcode reader face recognition terminal etc The number of the passage lanes can be increased with STD 01 double sided section i...

Страница 11: ...r plate 6 central post rear panel 7 side post 8 front panel 9 front end indication block 10 section top cover 11 top cover indication block 12 top duct 13 filling glass 14 bottom duct cover 15 bottom duct 16 power supply cable 17 RC panel with the cable 18 Fire Alarm cable1 19 DC connection cable 20 CAN connection cable Not included in the standard delivery set 10 ...

Страница 12: ...nd indication block 10 section top cover 11 top cover indication block 12 top duct 13 filling glass 14 bottom duct cover 15 bottom duct 16 power supply cable1 17 RC panel with cable 18 Fire Alarm cable1 19 to the Master section side DC cable 20 to the Master section side CAN cable 21 from the Slave section side DC cable 22 from the Slave section side CAN cable2 1 Not included in the standard deliv...

Страница 13: ... swing panel 1 Slave section is connected to Master section with two connection cables 19 20 Use double sided sections to arrange more passage lane The double sided section is completed with an RC panel and equipped with two swing panels 1 on the Master side and on the Slave side Each swing panel has its motor drive Slave side is connected to the speed gate Master section or to the Master side of ...

Страница 14: ...gate It displays the constant indication white arrow or red cross red indicator of passage denial white indicator of the passage direction The type of indication of the front end block can be chosen during the installation of the speed gate by connecting the front end cable to the corresponding indication control module connector located under the speed gate cover on the protection plate Fig 20 By...

Страница 15: ...cesses the incoming control commands transferred to Unlock A Stop Unlock B and Fire Alarm control inputs monitors the status of swing panels turn optical sensors and creates commands for the motor drive of the speed gate swing panels on the basis of the data received The microcontroller also creates signals on the control board outputs for indication on the RC panel Led A Led Stop and Led B output...

Страница 16: ... operating mode FA_Dir to choose swing panel direction of rotation in case an emergency passage opening Fire Alarm signal is sent By default the switch is in OFF position which corresponds to the swing gate being opened in B direction Size1 Size2 to set the speed gate swing panels size By default both switches are in OFF position Table 1 Positioning of Size1 Size2 switches according to the swing p...

Страница 17: ...s Speed gate operation is performed by sending control signals to Unlock A Stop and Unlock B outputs The control signal is sending a low level signal to Unlock A Stop and Unlock B contacts regarding GND contacts Normally open relay contact or layout with an open collector output can serve as a control element Fig 10 and 11 Speed gate emergency unlocking is performed by sending a control signal to ...

Страница 18: ...ntial control mode Control mode will be changed after speed gate being powered Pulse control mode The mode is used for speed gate operation from RC panel wireless remote control and ACS controller with the outputs supporting pulse control mode Speed gate operation at pulse control mode is described in Table 7 Control signal duration at sending control command to control inputs is to be not less th...

Страница 19: ...tes a command for the swing panels motor drive to open the passage The Time of holding in unlocked state 8 seconds by default countdown begins 3 The speed gate swing panels open in the chosen direction The user can pass through the speed gate in the chosen direction 4 Any movement detected in the passageway is registered as a completed passage PASS A or PASS B relay output corresponding to the pas...

Страница 20: ...ith a flexible multicore cable to Unlock A Stop Unlock B Led A Led Stop Led B Sound and GND contacts of the X2 terminal block according to the speed gate connection layout Fig 18 Figure 12 Standard RC panel orientation regarding speed gate sections Note WRC is connected to Unlock A Stop Unlock B and GND contacts of the X2 terminal block Power supply of the WRC is connected to 12V contact of the X3...

Страница 21: ...ortunity of built in proximity card readers installation under the section top cover ACS controller outputs are connected to Unlock A Stop Unlock B and GND contacts of the X2 terminal block ACS controller inputs are connected to PASS A PASS B and to Common contacts of the X3 terminal block Connection is performed in accordance with the speed gate connection layout Fig 18 5 4 Optional devices conne...

Страница 22: ... voltage 42 V maximum commutation current 0 25 A closed contact resistance max 0 15 Ohm Maximum consumption current of the siren connected to the contact 12V of the X3 connector block on control board should not exceed 0 3 A 5 4 3 External indication External indication blocks for corresponding passage directions are connected to Light A and Light B outputs Outputs have the full contact block NO n...

Страница 23: ...ls 116 48 12 cm Box with ATG 425 set of swing panels 78 60 12 cm Box with ATG 425 set of swing panels 78 65 8 cm Transportation boxes weight gross ST 01 Box 1 ST 01 M section max 125 kg Box 2 ST 01 S section max 125 kg STD 01 Box 1 double sided section max 140 kg Box with STC 01 set of section top covers max 24 kg Box with SDC 01 double sided section cover max 18 kg Box with ATG 300 set of swing p...

Страница 24: ...ion and declines any claims arising thereof in case the installation is not done in compliance with the instructions provided in this Manual 8 1 Installation details It is recommended to mount the speed gate on a steady and level concrete grade 400 or higher strength class B22 5 stone or similar foundation at least 150 mm thick to level the foundation so that the anchoring points of the speed gate...

Страница 25: ...location for Master and Slave sections and for double sided section if needed However it is necessary to consider the sections relative positioning the Master section panel side of the double sided section should always been placed opposite to the Slave section panel side of the double sided section 3 Mark and drill holes for anchor sleeves on the mounting surface for fastening speed gate sections...

Страница 26: ...ck and install the double sided section Act as described in points 7 9 for both sides of the section Place the double sided section so its Slave side stands towards the installed Master section 13 Take DC and CAN connection cables out of the central post of the double sided section from the Slave side if they hadn t been routed in the cable channel earlier Lead them through the hole that is locate...

Страница 27: ...hem Fig 21 Sect 8 9 3 23 Mount swing panel cover plate 4 from installation kit Fig 21 Sect 8 9 4 24 Mount front panels 8 Sect 8 9 2 After installation make sure that the top edges of the panels are flush with the section housing Front end indication block panel should be installed where indication control module is located This module is fixed to one of the two steel protection plates in the top d...

Страница 28: ...ST 01 Speed gate STD 01 Double sided section 8 5 Mounting surface marking layouts Figure 15 Speed gate marking layout ATG 425 swing panel dimensions are given in brackets 27 ...

Страница 29: ...Assembly and Operation Manual Figure 16 Speed gate and double sided section marking layout ATG 425 swing panel dimensions are given in brackets 28 ...

Страница 30: ...ster section section side 1 A2 Slave section section side 1 A2 1 ST 01 761 drive control board Slave section section side 1 A3 RC panel 1 A41 Speed gate PS 1 A51 Fire Alarm signal sending device 1 A6 11 A6 21 ACS controller 1 A71 Wireless remote control 1 A81 12V DC siren 1 A9 11 A9 21 Remote indication block 2 A101 Remote indicators PS 1 1 2 DC connection cable 2 3 4 CAN connection cable 2 5 Wire...

Страница 31: ... adjusting manually speed gate swing gates initial position Proceed as follows 1 Turn off the speed gate power supply 2 Switch the R2 switch to the ON position R1 switch should be in OFF position 3 Arrange the swing panels into the required initial position and adjust them relatively to each other 30 ...

Страница 32: ...d for the Auto opening mode if the speed gate is not occupied for passage from the opposite direction the green indicator passage granting is constantly lit but in the other direction of the passage the red indicator passage denial is lit In case if the passage from the opposite direction is authorized from RC panel WRC kit or ACS controller the Auto opening mode is turned off for the time of this...

Страница 33: ...omponents from falling and damage place them on an even and steady surface prevent them from scratches 8 9 1 Central post cover plate To remove the central post cover plate 5 pull the cover plate down along the post take it aside from the post bringing the hooks from slots in the central post Fig 19 Central post cover plate is to be installed in the reverse order Figure 19 Central post cover plate...

Страница 34: ... indication block Side post front panel assembly is to be installed in the reverse order Prior to mounting removing the side post panel section top cover 10 is to be removed first see Sect 8 9 6 Figure 20 Side post front panel disassembly the dashed line shows the location of the reader 8 9 3 Swing panel Two people shall install and remove the swing panels The swing panel is fixed to the rotating ...

Страница 35: ...ted in the bottom part of the rotating support Fig 21 3 Fix the installed part of the cover plate with a Philips screwdriver to the rotating support with two M4 10 screws with washers from the delivery set 4 Turn fully the rotating support of swing panel in the counterclockwise direction Mount the second part of the cover plate likewise 5 Check the gaps between swing panel and its cover plates bet...

Страница 36: ... indication block on the surface located above the rotating support of swing panel and using an SW4 Allen wrench fix it on the post top duct 12 using two M5 12 screws with washers from the delivery set 4 Check the evenness of the gap between the indications module and the swing panel cover plate loosen the M4 10 screws and tighten them if needed Remove the central post indication block in a revers...

Страница 37: ... the installation kit through the holes in the bottom part of the top duct of the section Figure 23 Installation of the STC 01G SDC 01G section top cover Installation order of the STC 01GS SDC 01GS section top covers see Fig 24 Take one glass piece of the top cover featuring an indication block and connect the connection cable of the indication control module PASS connector Fig 20 to the top cover...

Страница 38: ...n to the gaps between the top cover and the duct along the whole perimeter repeat steps again if necessary Remove the top cover in the reverse order Attention During long term and intensive operation of the turnstile with built in readers scratches and scuff marks can appear on the glass surface either from access cards presentation as well as from wallets bags wristbands watches rings etc or from...

Страница 39: ...l cover plate 4 Sect 8 9 4 4 Remove the central post cover plate 5 Sect 8 9 1 5 Remove both covers from the bottom duct 14 Sect 8 9 7 6 For ST 01 section remove the central post rear panel 6 Unscrew 2 M6 16 screws for SW5 Allen wrench in the bottom ducts M6 16 screws for SW5 Allen wrench at the bottom of the central post and 2 M5 12 screws for SW4 Allen wrench in the top duct Fig 29 For STD 01 sec...

Страница 40: ...STD 01 Double sided section Figure 27 Filling glass fixing in the ST 01 central post Figure 28 Filling glass fixing in the central post of the double sided section STD 01 Figure 29 Central post rear panel disassembly 39 ...

Страница 41: ...is ready for operation 9 2 Pulse control mode Speed gate control command sending from the RC panel and its indication on the speed gate sections is performed in accordance with Table 7 Passage directions are independent of each other i e sending a command for one direction doesn t change the opposite direction mode Table 7 Pulse control mode Indication Command RC panel operator actions1 RC panel C...

Страница 42: ...ntact Red Stop indicator is on Red for both directions Swing panels are closed Direction open Low level on the contact of the chosen direction High level on all other contacts Green indicator of the chosen Left Right direction is on Green for the chosen direction Swing panels turn in the passage direction Both directions open Low level on Unlock A and Unlock B contacts High level on Stop contact B...

Страница 43: ...able Disconnect the speed gate power supply from the mains open the central post cover plate Check the integrity of the power cable check the reliability of the power cords in the XT3 terminal block of the control board One of the indication blocks does not work while the speed gate operation corresponds to the algorithm No control signal is sent to the indication block Check the integrity of the ...

Страница 44: ...e contact Stop and a high level at the contact Unlock A or active front is at the contact Stop while there is a low level at the contact Unlock B and a high level at contact Unlock A At this command the passage direction B opens until the command Always locked is received the status of the passage direction A does not change at that Free passage open for free passage in both directions Active fron...

Страница 45: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com ...

Страница 46: ...www perco com ...

Отзывы: