IR-03.1 Proximity Reader
For reader mounting a metal base-plate is included in delivery set.
The metal base-plate has 4 holes to fix it with screws to mounting surface. Reader is fixed
to metal base-plate with a screw in lower part of reader housing.
4.2 Operation principle
Readers provide code reading from Proximity identifiers with operation frequency 125 kHz
(hereinafter – the identifier) produced by HID Corporation type ProxCard II, ISOProx II,
trinkets ProxKey II (standard formats HID: 26 bit (H10301), 37 bit (H10302, H10304)), and
the production of EM-Microelectronic-Marin SA.
Code reading is provided by presenting identifier to the reader, while identifier can be
placed inside pocket, wallet or any other magneto transparent container (cover). Maximum
distance possible for identifier sensing by the reader depends on the type of identifier.
When switched on the reader radiates close low frequency (125 kHz) electromagnetic
field. Caught in this field the identifier activates and starts transmitting individual encoded
signal received by the reader.
Reader transforms the input signal in accordance with an external device interface and
sends it to controller of external device via
RS-485
interface.
Figure 1. Reader operation
5 SAFETY REQUIREMENTS
Attention!
Before mounting and first switch-on carefully study this manual.
Reader installation must be carried out by circuit installer.
Use only serviceable tools at reader installation.
Joining of all connectors is made only upon power supply off.
Cable laying should be produced subject to electrical devices operation rules.