background image

IR-03.1 Proximity Reader  

6.3  Installation tools 

  1.2÷1.5 kW hammer drill; 

  Ø16 mm hard-alloyed drill bits; 

  Ø5 mm hard-alloyed drill bits; 

  Flat slot screwdriver No2; 

 Mounting 

knife; 

 Level; 

  Measuring tape (2 m). 

 

Figure 3.  

IR-03.1

 reader installation layout 

(reader housing is dotted) 

Figure 4.  Piezoelectric element (

B1

), 

jumpers «reader number» (

XP2

), jumper 

«switch off end-of-line resistor» (

XP1

6.4  Installation procedure 

Assembly order: 

1.  Select the reader mounting place. Factors to be considered are given in clause 6.1. 

2.  Make the marking and holes in mounting surface for fixing the base-plate and cable 

laying from the reader (Ref. Fig. 3). 

3.  Release the screw at reader bottom fixing it to metal base-plate. Take off the metal 

base-plate and fasten it with 4 screws from delivery set.  

Содержание IR-03.1

Страница 1: ...Proximity Reader IR 03 1 CERTIFICATE ASSEMBLY AND OPERATION MANUAL...

Страница 2: ...Proximity Reader IR 03 1 Certificate Assembly and Operation Manual TC RU C RU 02 B 00368 4372 034 88226999 2012...

Страница 3: ...DUCT DESCRIPTION 4 4 1 Design 4 4 2 Operation principle 5 5 SAFETY REQUIREMENTS 5 6 INSTALLATION INSTRUCTIONS 6 6 1 Installation details 6 6 2 Cables parameters 6 6 3 Installation tools 7 6 4 Installa...

Страница 4: ...less than 24 hours indoors within normal climate conditions prior to putting it in operation Marking of the reader is made in form of a label located on the rear panel of the reader housing The label...

Страница 5: ...s off if the light was on and switches on if the light was off Reader protection from environmental exposures is ensured by covering its board with compound Shield cable for reader connection is outpu...

Страница 6: ...llet or any other magneto transparent container cover Maximum distance possible for identifier sensing by the reader depends on the type of identifier When switched on the reader radiates close low fr...

Страница 7: ...unted behind metal surface it is necessary to cut out the window in it and install the reader opposite and equidistant to window edges Ref Fig 2 provided that window measures are min 225 130 mm The wi...

Страница 8: ...oelectric element B1 jumpers reader number XP2 jumper switch off end of line resistor XP1 6 4 Installation procedure Assembly order 1 Select the reader mounting place Factors to be considered are give...

Страница 9: ...ot the end device of RS 485 communication line please cut by nippers the jumper switch off end of line resistor It is necessary to install end of line resistors at RS 485 line ends in this case 6 Lay...

Страница 10: ...roduct to the Customer All claims with regard to quantity completeness and defects to appearance of the Product delivered are accepted by the Manufacturer in writing within no more than 5 five working...

Страница 11: ...ave been detected the Customer is responsible for compensation of the Manufacturer s expenses related to the examination Apart from the warranties mentioned above the Manufacturer does not provide any...

Страница 12: ...e of sale ____________________ 20___ ____________________________________ signature seal Cutting line Warranty Repair Coupon IR 03 1 Proximity reader Serial number 5 4 7 Date of manufacture __________...

Страница 13: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Страница 14: ...www perco com...

Отзывы: