Cable length

..................................................................................................................

0.8 m 

Distance between the reader and external controller  

for cable type 

F/UTP2-Cat5e 2×2×0,52

........................................................ max. 50 m 

maximal  ............................................................................................................ 200 m

2

 

Mean lifetime  ...........................................................................................................  8 years 

Ingress Protection Rating ..........................................................................  IP67 (EN 60529) 

Electric shock protection class ...................................................................... III (IEC 61140) 

Reader dimensions (without cable)...............................................................145×50×20 mm 

Reader weight...................................................................................................... max. 230 g 

3  DELIVERY SET 

Reader 

IR-03

 ......................................................................................................................1 

Metal base-plate .................................................................................................................1 

Assembly set: 

Plastic dowels .............................................................................................................4 

Screws .......................................................................................................................4 

Package ..............................................................................................................................1 

Assembly and operation manual .........................................................................................1 

4  PRODUCT DESCRIPTION 

4.1  Design 

Reader consists of a unit in plastic housing with three-color LED indicator on the front 
panel: green (upper), yellow (central) and red (lower). Reader comes with a sound 
indication.  

The card code reading is confirmed by the short-time sound signal and alteration of the 
yellow (central) light indicator’s state (switches off if the light was on and switches on if the 
light was off).  

Reader protection from environmental exposures is ensured by covering its board with 
compound. Shield cable for reader connection is output on its rear side.  

Also the reader back side features two jumpers:  

  closer to reader centre – three jumpers “reader number” (see Table 1); 

  closer to reader lower edge – jumper "switch off end-of-line resistor" (jumper uncut 

– end-of-line resistor is present, after cutting the jumper – end-of-line resistor is 
switched off). 

 

Note: 

Up to 8 readers can be connected to one controller. In this case, each reader using 
the jumper "reader number" must set an individual number (see Table 1). All readers 
with even numbers will be tied to one direction of the pass, and all readers with odd 
numbers to the other. Reference of the reader number to a passage direction is 
programmed by the software.  

                                            

2

 Maximum distance between the reader and external controller depends on the cable cross-section. 

For selecting the cable type please contact  PERCo specialists. 

Содержание IR-03.1

Страница 1: ...Proximity Reader IR 03 1 CERTIFICATE ASSEMBLY AND OPERATION MANUAL...

Страница 2: ...Proximity Reader IR 03 1 Certificate Assembly and Operation Manual TC RU C RU 02 B 00368 4372 034 88226999 2012...

Страница 3: ...DUCT DESCRIPTION 4 4 1 Design 4 4 2 Operation principle 5 5 SAFETY REQUIREMENTS 5 6 INSTALLATION INSTRUCTIONS 6 6 1 Installation details 6 6 2 Cables parameters 6 6 3 Installation tools 7 6 4 Installa...

Страница 4: ...less than 24 hours indoors within normal climate conditions prior to putting it in operation Marking of the reader is made in form of a label located on the rear panel of the reader housing The label...

Страница 5: ...s off if the light was on and switches on if the light was off Reader protection from environmental exposures is ensured by covering its board with compound Shield cable for reader connection is outpu...

Страница 6: ...llet or any other magneto transparent container cover Maximum distance possible for identifier sensing by the reader depends on the type of identifier When switched on the reader radiates close low fr...

Страница 7: ...unted behind metal surface it is necessary to cut out the window in it and install the reader opposite and equidistant to window edges Ref Fig 2 provided that window measures are min 225 130 mm The wi...

Страница 8: ...oelectric element B1 jumpers reader number XP2 jumper switch off end of line resistor XP1 6 4 Installation procedure Assembly order 1 Select the reader mounting place Factors to be considered are give...

Страница 9: ...ot the end device of RS 485 communication line please cut by nippers the jumper switch off end of line resistor It is necessary to install end of line resistors at RS 485 line ends in this case 6 Lay...

Страница 10: ...roduct to the Customer All claims with regard to quantity completeness and defects to appearance of the Product delivered are accepted by the Manufacturer in writing within no more than 5 five working...

Страница 11: ...ave been detected the Customer is responsible for compensation of the Manufacturer s expenses related to the examination Apart from the warranties mentioned above the Manufacturer does not provide any...

Страница 12: ...e of sale ____________________ 20___ ____________________________________ signature seal Cutting line Warranty Repair Coupon IR 03 1 Proximity reader Serial number 5 4 7 Date of manufacture __________...

Страница 13: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Страница 14: ...www perco com...

Отзывы: