Certificate & Operation Manual
16
3. Add the following Internal response in
"Configuration"
→
"Edit"
→
"Internal response"
section:
−
"Source type:"
– "Visitor ID card presentation",
−
"Source number:"
– "1"
(number of OD that is physically connected to the card
capture reader),
−
"Source direction:"
– "1" or "2"
(depending on the passage direction that is
controlled by the card capture reader),
−
"Receiver type:"
– "Activate output",
−
"Receiver number:" - "3"
(number of the output that is physically connected to the
“Capture card” input of the card capture reader),
−
"Response characteristic:"
– "Response time":
4. Any free input of the controller can be used for receiving the "Alarm" signal sent by the card
capture reader. It is necessary to set the type of response on the activation of this input, for
example, blocking of the reader in the passage direction that is controlled by the card
capture reader: