PER-EKO type KSW & KSW PLUS – Instruction Manual
3
INTRODUCTION
Dear purchaser and user of the boiler type KSW & KSW PLUS – the following start-up and technical
documentation comprises all the information necessary to operate and maintain our boiler type KSW & KSW PLUS.
1. GENERAL INFORMATION
The purpose of the following instruction manual is to familiarize the user with the operation of the solid fuel
boiler. Before installing and using the boiler, every user ought to get acquainted with the instruction manual. The manual
comprises recommendations and clues concerning handling and appropriate use of the boiler.
Violation of the terms, conditions and clues enclosed in the following documentation frees the boiler
manufacturer from any obligations and warranties.
As a standard feature, KSW PLUS boilers have an inbuilt electronic temperature controller with a fan.
Before the boiler is installed, one ought to get acquainted with the instruction manual and make sure
that the boiler did not get damaged during transport and that the equipment is complete.
1.1 Application
Steel central heating boiler KSW & KSW PLUS is meant for providing water-based heating for family houses,
garages, utility rooms, etc.
The highest water temperature in the boiler cannot exceed 95 °C.
The boilers belong to a group of low-temperature boilers and are not subject to registration in the District Office of
Technical Supervision. The boilers are meant to operate in central heating water systems with gravitational or forced
circulation in an open thermal cycle, both having all the safety features in accordance with the requirements of the PN-
91/B-02413 norms, which relate to the security of water - supported heating of an open thermal cycle.
Boiler’s technical specification:
Boiler type
Nominal power
[kW]
Utility room height [m]
Size of heated surface*
[m
2
]
Cubic capacity of
heated surface [m
3
]
KSW 5
5
2,5
45
110
KSW 9
9
2,5
75
185
KSW 12
12
2,5
100
250
KSW 16
16
2,5
130
325
KSW 18
18
2,5
150
375
KSW 24
24
2,5
200
500
KSW 30
30
2,5
250
625
KSW 35
35
2,5
340
850
KSW 40
40
2,5
380
950
KSW 50
50
2,5
500
1250
* depending on the insulation of a building;
1. 2 Fuel
The basic fuel used with the KSW & KSW PLUS boilers is coal of the following granulation: 20÷40 mm or 40÷60
mm, with a fuel value of about 25 MJ/kg. The substitute fuel is a mixture of coke (type OI or OII) and coal type 32.1, range
nut coal class II 24/12, according to norm PN-82/C-97001-3 and a proportion of both fuels 1:1 or 2:1. The substitute fuel can
also be a mixture of nut coal (70%) and dust coal (30%). It is not recommended to burn entirely with dust coal with boilers
KSW and KSW PLUS. Other fuels not mentioned in the Instruction Manual (i.e. briquettes from hard coal or brown coal,