background image

 

 

 

 

7.3

 

Connect Clients to Cloud

 

SpeedFusion Cloud provides a convenient way to route the LAN client to the cloud. From 

SpeedFusion Cloud > Connect Clients to Cloud

 

 

 

 

 

 

 

 

 

 

 

Содержание MAX 700

Страница 1: ...s of their respective owners MAX Series User Manual Pepwave Products MAX 700 HD2 HD2 IP67 HD2 Mini HD2 MBX HD Dome HD4 HD4 MBX MBX Mini HD4 IP67 Transit Transit Duo Transit 5G Transit Core Transit Mini Transit Pro E BR1 Classic BR1 MK2 BR1 Slim BR1 ENT BR1 M2M BR1 Mini BR1 Mini Core BR1 ESN BR1 Pro LTE BR1 Pro 5G BR1 IP55 BR1 IP67 BR2 IP55 On The Go HD2 with MediaFast HD4 with MediaFast SpeedFusio...

Страница 2: ...wave MAX Mobile Router Overview 14 MAX 700 14 MAX HD2 16 MAX HD2 IP67 18 MAX HD2 mini 19 MAX HD Dome 20 MAX Transit MAX Transit Duo CAT 12 22 MAX Transit CAT 18 24 MAX Transit 5G 26 MAX Transit Mini 27 MAX Transit Pro E 28 MAX Transit Core 29 MAX BR1 ESN 31 MAX HD2 and HD4 with MediaFast 32 MAX HD4 35 MAX HD4 MBX CAT 12 37 MAX HD2 4 MBX CAT 18 39 MAX MBX Mini 40 MAX HD4 IP67 41 MAX BR1 Classic 42 ...

Страница 3: ...VoIP 66 Per User Bandwidth Control 67 High Availability via VRRP 67 USB Modem and Android Tethering 68 Built In Remote User VPN Support 68 SIM card USSD support 69 KVM Virtualization 69 DPI Engine 70 NetFlow 70 Wi Fi Air Monitoring 70 SP Default Configuration 70 Installation 71 Preparation 71 Constructing the Network 71 Configuring the Network Environment 72 Mounting the Unit 73 Wall Mount 73 Car ...

Страница 4: ...ion 119 PPPoE Connection 121 L2TP Connection 122 GRE Connection 124 Cellular WAN 126 Wi Fi WAN 132 Creating Wi Fi Connection Profiles 138 WAN Health Check 139 Dynamic DNS Settings 141 Advanced Wi Fi Settings 143 MediaFast Configuration 147 Setting Up MediaFast Content Caching 147 Scheduling Content Prefetching 148 Viewing MediaFast Statistics 151 ContentHub 152 Configuring the ContentHub 152 Confi...

Страница 5: ...Latency 184 Expert Mode 184 Port Forwarding 186 UPnP NAT PMP Settings 187 NAT Mappings 189 QoS 191 User Groups 191 Bandwidth Control 192 Application 192 Application Prioritization 192 Prioritization for Custom Applications 192 DSL Cable Optimization 193 Firewall 194 Outbound and Inbound Firewall Rules 195 Access Rules 195 Apply Firewall Rules to PepVpn Traffic 199 Intrusion Detection and DoS Preve...

Страница 6: ...TP Forwarding 216 Web Proxy Forwarding 217 DNS Forwarding 218 Custom Service Forwarding 218 Service Passthrough 218 UART 220 GPS Forwarding 222 Ignition Sensing 222 Ignition Sensing installation 223 GPIO Menu 225 NTP Server 226 Grouped Networks 226 Remote SIM Management 228 SIM Toolkit 230 AP 232 AP Controller 232 Wireless SSID 232 Wireless Mesh 236 Settings 237 AP Controller Status 243 Info 243 A...

Страница 7: ...SMS Control 267 InControl 268 Configuration 268 Feature Add ons 269 Reboot 270 Tools 271 Ping 271 Traceroute Test 272 PepVPN Test 272 Wake on LAN 273 CLI Command Line Interface Support 273 Status 274 Device 274 GPS Data 276 Active Sessions 276 Client List 278 WINS Client 279 UPnP NAT PMP 279 OSPF RIPv2 280 BGP 280 SpeedFusion Status 281 Event Log 283 WAN Quality 285 Usage Reports 286 ...

Страница 8: ...Real Time 286 Hourly 287 Daily 287 Monthly 288 Appendix A Restoration of Factory Defaults 291 Appendix B FusionSIM Manual 292 Appendix C Declaration 304 ...

Страница 9: ...ies has a wide range of products suitable for many different deployments and markets Entry level SD WAN models such as the MAX BR1 are suitable for SMEs or branch offices High capacity SD WAN routers such as the MAX HD2 are suitable for larger organizations and head offices This manual covers setting up Pepwave routers and provides an introduction to their features and usage Tips Want to know more...

Страница 10: ... Qualified Domain Name HSDPA High Speed Downlink Packet Access HTTP Hyper Text Transfer Protocol ICMP Internet Control Message Protocol IP Internet Protocol LAN Local Area Network MAC Address Media Access Control Address MTU Maximum Transmission Unit MSS Maximum Segment Size NAT Network Address Translation PPPoE Point to Point Protocol over Ethernet QoS Quality of Service SNMP Simple Network Manag...

Страница 11: ...ns can be bonded together using our SpeedFusion technology This allows better reliability larger bandwidth and increased wireless coverage compared to use only one 4G LTE modem Below is a list of supported features on Pepwave routers Features vary by model For more information please see peplink com products 1 1 Supported Network Features 1 1 1 WAN Ethernet WAN connection in full half duplex Stati...

Страница 12: ...e Internet traffic to a remote VPN peer Optional pre shared key setting SpeedFusionTM throughput ping and traceroute tests PPTP server PPTP and IPsec passthrough 1 1 4 Firewall Outbound LAN to WAN firewall rules Inbound WAN to LAN firewall rules per WAN connection Intrusion detection and prevention Specification of NAT mappings Outbound firewall rules can be defined by destination domain name 1 1 ...

Страница 13: ...ity and Enforced algorithms 1 1 7 AP Controller Configure and manage Pepwave AP devices Review the status of connected APs 1 1 8 QoS Quality of service for different applications and custom protocols User group classification for different service levels Bandwidth usage control and monitoring on group and user level Application prioritization for custom protocols and DSL cable optimization ...

Страница 14: ...iguration via WAN and LAN interfaces Time server synchronization SNMP Email notification Read only user access for web admin Shared IP drop in mode Authentication and accounting by RADIUS server for web admin Built in WINS servers Syslog SIP passthrough PPTP packet passthrough Event log Active sessions Client list WINS client list UPnP NAT PMP Real time hourly daily and monthly bandwidth usage rep...

Страница 15: ...view 2 1 MAX 700 2 1 1 Panel Appearance 2 1 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready ...

Страница 16: ...work without traffic Wi Fi AP OFF Disabled Blinking slowly Enabled but no client connected Blinking Connected to network with traffic ON Client s connected to wireless network LAN and Ethernet WAN Ports Green LED ON 10 100 1000 Mbps Orange LED Blinking Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports ...

Страница 17: ...2 2 MAX HD2 For certification information please refer to Appendix B Declaration 2 2 1 Panel Appearance ...

Страница 18: ... wireless network s Blinking Connected to wireless network s with traffic ON Connected to wireless network s without traffic Cellular Indicators Cellular 1 Cellular 2 OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s LAN and Ethernet WAN Ports Green LED ON 1000 Mbps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected...

Страница 19: ... 2 3 1 Panel Appearance 2 3 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready ...

Страница 20: ... front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready Cellular Indicators Cellular 1 Cellular 2 OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s ...

Страница 21: ...reen LED ON POE Enabled OFF POE Disabled Orange LED Blinking 10 100 1000 Mbps and Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports 2 5 MAX HD Dome 2 5 1 Panel Appearance ...

Страница 22: ......

Страница 23: ... MAX Transit Duo CAT 12 2 6 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready ...

Страница 24: ...to network s For MAX TST_DUO Wi Fi Indicators Wi Fi OFF Wi Fi AP is turn off Blinking Wi Fi AP is turn on LAN and Ethernet WAN Ports Green LED ON 1000 Mbps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected without traffic Blinking Data is transferring OFF Port is not connected Port Type Auto MDI MDI X ports ...

Страница 25: ... Transit CAT 18 2 7 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready ...

Страница 26: ...to network s For MAX TST_DUO Wi Fi Indicators Wi Fi OFF Wi Fi AP is turn off Blinking Wi Fi AP is turn on LAN and Ethernet WAN Ports Green LED ON 1000 Mbps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected without traffic Blinking Data is transferring OFF Port is not connected Port Type Auto MDI MDI X ports ...

Страница 27: ...ors Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready Cellular Indicators Cellular 1 Status OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s Wi Fi Indicators Wi Fi OFF Wi Fi AP is turn off Blinking Wi Fi AP is turn on ...

Страница 28: ... is not connected Port Type Auto MDI MDI X ports 2 9 MAX Transit Mini 2 9 1 Panel Appearance 2 9 2 LED indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready Wi Fi Indicators Wi Fi OFF Disabled intermittent Blinking slowly Connecting to wireless network s ...

Страница 29: ...sabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s 2 10 MAX Transit Pro E 2 10 1 Panel Appearance 2 10 2 LED indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready ...

Страница 30: ... Port and Ethernet WAN Port Green LED ON 1000 Mbps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected without traffic Blinking Data is transferring OFF Port is not connected Port Type Auto MDI MDI X ports Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s 2 11 MAX Transit Core 2 11 1 Pane...

Страница 31: ...led OFF POE Disabled Orange LED Blinking 10 100 1000 Mbps with activity OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports LAN 2 3 Ports WAN Port Right LED GREEN 1000 Mbps OFF 10 100 Mbps or ports are not connected Left LED ORANGE Port is connected without traffic Blinking Data is transferring OFF Port is not connected ...

Страница 32: ...gineering use USB Ports For connecting 4G 3G USB modems 2 12 MAX BR1 ESN 2 12 1 Panel Appearance 2 12 2 LED indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error ...

Страница 33: ...ork s Blinking Connected to wireless network s with traffic ON Connected to wireless network s without traffic Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s 2 13 MAX HD2 and HD4 with MediaFast 2 13 1 Panel Appearance ...

Страница 34: ...affic ON Connected to wireless network s without traffic Cellular Indicators Cellular 1 Cellular 2 OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s LAN Ports Green LED ON POE Enabled OFF POE Disabled Orange LED Blinking 10 100 1000 Mbps and Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI ...

Страница 35: ...OFF Port is not connected Port Type Auto MDI MDI X ports ...

Страница 36: ...2 14 MAX HD4 2 14 1 Panel Appearance 2 14 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators ...

Страница 37: ...lular 1 Cellular 2 OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s LAN Ports Green LED ON POE Enabled OFF POE Disabled Orange LED Blinking 10 100 1000 Mbps and Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports Ethernet WAN Ports Green LED ON 1000 Mbps OFF 10 Mbps 100 Mbps or port i...

Страница 38: ...lease refer to Appendix B Declaration 2 15 1 Panel Appearance 2 15 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready ...

Страница 39: ...ing to wireless network s Blinking Connected to wireless network s with traffic ON Connected to wireless network s without traffic LAN and Ethernet WAN Ports Green LED ON 10 100 1000 Mbps Orange LED Blinking Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports ...

Страница 40: ...ws Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready Wi Fi AP and Wi Fi WAN Indicators Wi Fi WAN Cellular 1 Cellular 2 OFF Disabled Intermittent Blinking slowly Connecting to network s Blinking Connected to network s with traffic ON Connected to network s without traffic ...

Страница 41: ... X ports 2 17 MAX MBX Mini 2 17 1 Panel Appearance 2 17 2 LED Indicators The statuses indicated by the front panel LEDs are as follows LED Indicator Power LED OFF Power off GREEN Power on LAN Ports Green LED ON POE Enabled OFF POE Disabled Orange LED Blinking 10 100 1000 Mbps with activity OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports ...

Страница 42: ...t is connected without traffic Blinking Data is transferring OFF Port is not connected Port Type Auto MDI MDI X ports Console USB Ports Console Port Reserved for engineering use USB Ports For connecting 4G 3G USB modems 2 18 MAX HD4 IP67 2 18 1 Panel Appearance 2 18 2 LED Indicators ...

Страница 43: ...LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready 2 19 MAX BR1 Classic For certification information please refer to Appendix B Declaration 2 19 1 Panel Appearance ...

Страница 44: ...red Boot up error Green Ready Wi Fi Indicators Wi Fi OFF Disabled intermittent Blinking slowly Connecting to wireless network s Blinking Connected to wireless network s with traffic ON Connected to wireless network s without traffic Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s ...

Страница 45: ...se refer to Appendix B Declaration 2 20 1 Panel Appearance 2 20 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready ...

Страница 46: ...k s without traffic Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s LAN and Ethernet WAN Ports Green LED ON 1000 Mbps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected without traffic Blinking Data is transferring OFF Port is not connected Port Type Auto MDI MDI X ports ...

Страница 47: ... up or busy Blinking red Boot up error Green Ready Wi Fi Indicators Wi Fi OFF Disabled intermittent Blinking slowly Connecting to wireless network s Blinking Connected to wireless network s with traffic ON Connected to wireless network s without traffic Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s ...

Страница 48: ... 10 Mbps Orange LED ON Port is connected without traffic Blinking Data is transferring OFF Port is not connected Port Type Auto MDI MDI X ports 2 22 MAX BR1 Mini For certification information please refer to Appendix B Declaration 2 22 1 Panel Appearance ...

Страница 49: ...cators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s ...

Страница 50: ...FF Disabled intermittent Blinking slowly Connecting to wireless network s Blinking Connected to wireless network s with traffic ON Connected to wireless network s without traffic 2 23 MAX BR1 Mini Core 2 23 1 Panel Appearance ...

Страница 51: ...Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s 2 24 MAX BR1 M2M 2 24 1 Panel Appearance ...

Страница 52: ...2 24 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators ...

Страница 53: ...s Cellular OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s LAN and Ethernet WAN Ports Green LED ON 100 Mbps OFF 10 Mbps Orange LED ON Port is connected without traffic Blinking Data is transferring OFF Port is not connected Port Type Auto MDI MDI X ports ...

Страница 54: ...Booting up or busy Blinking red Boot up error Green Ready Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking slowly Connecting to network s Green Connected to network s LAN and Ethernet WAN Ports Green LED ON 10 100 1000 Mbps Orange LED Blinking Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports ...

Страница 55: ...d by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking Slowly Connecting to network s Green Connected to network s ...

Страница 56: ...ng Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports 2 27 MAX BR1 Pro 5G 2 27 1 Panel Appearance 2 27 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready ...

Страница 57: ...bps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected without traffic Blinking Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports WAN Port Right LED ON 1000 Mbps OFF 10 Mbps 100 Mbps or port is not connected Left LED ON Port is connected without traffic Blinking Data is transferring OFF No data is being transfer...

Страница 58: ...front panel LEDs are as follows LAN and Ethernet WAN Ports Green LED ON 1000 Mbps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected without traffic Blinking Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports ...

Страница 59: ... Indicators Status OFF System initializing Red Booting up or busy Blinking red Boot up error Green Ready LAN and Ethernet WAN Ports Green LED ON 1000Mbps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected without traffic Blinking Data is transferring OFF Port is not connected Port Type Auto MDI MDI X ports ...

Страница 60: ...ed or no SIM card inserted Blinking Connecting to network s in Standby Mode Green Connected to network s in Priority 1 Active LAN and WAN Indicators Green Powered on device connected to Ethernet port OFF No device connected to Ethernet port ...

Страница 61: ...ng Red Booting up or busy Blinking red Boot up error Green Ready Wi Fi Indicators Wi Fi OFF Disabled Intermittent Blinking slowly Connecting to wireless network s Blinking Connected to wireless network s with traffic ON Connected to wireless network s without traffic Cellular Indicators Cellular OFF Disabled or no SIM card inserted ON Connecting or connected to network s ...

Страница 62: ...D ON 1000Mbps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected without traffic Blinking Data is transferring OFF Port is not connected Port Type Auto MDI MDI X ports 2 31 MAX BR1 IP67 2 31 1 Panel Appearance ...

Страница 63: ...em is not attached to the port Green Modem is attached to the port Wi Fi Indicators Wi Fi OFF Disconnected from AP Green Connected to AP Status Indicators Status OFF System initializing Red Booting up or busy Green Ready LAN and Ethernet WAN Ports Green LED ON 100 Mbps OFF 10 Mbps Orange LED ON Port is connected without traffic Blinking Data is transferring ...

Страница 64: ...Port Type Auto MDI MDI X ports 2 33 SpeedFusion Engine 2 33 1 Panel Appearance 2 34 UBR LTE 2 34 1 Panel Appearance ...

Страница 65: ...LAN and Ethernet WAN Ports Green LED ON 1000 Mbps OFF 10 Mbps 100 Mbps or port is not connected Orange LED ON Port is connected without traffic Blinking Data is transferring OFF No data is being transferred or port is not connected Port Type Auto MDI MDI X ports Cellular Indicators Cellular OFF Disabled or no SIM card inserted Blinking Slowly Connecting to network s Green Connected to network s ...

Страница 66: ...2 35 PDX 2 35 2 LED Indicators The statuses indicated by the front panel LEDs are as follows Status Indicators Status OFF No battery installed Red Charging Blinking red Low Battery Green Full Charged ...

Страница 67: ...ithout making any changes to your network For any reason your Peplink router looses power the LAN Bypass will safely and automatically bypass the Peplink router to resume your original network connection Note Drop in mode is compatible for All MAX models except MAX BR1 IP67 VoIP and videoconferencing are highly sensitive to latency With QoS Peplink routers can detect VoIP traffic and assign it the...

Страница 68: ...et and set bandwidth limits for every user in the group 3 4 High Availability via VRRP When your organization has a corporate requirement demanding the highest availability with no single point of failure you can deploy two Peplink routers in High Availability mode With High Availability mode the second device will take over when needed Compatible with MAX 700 MAX HD2 All variants HD4 All Variants...

Страница 69: ... and above Compatible with MAX 700 HD2 all variants except IP67 HD4 All variants Use OpenVPN or L2TP with IPsec to safely and conveniently connect remote clients to your private network L2TP with IPsec is supported by most devices but legacy devices can also connect using PPTP Click here for the full instructions on setting up L2TP with IPsec Click here for the full instructions on setting up Open...

Страница 70: ...igure carrier specific services Click here for full instructions on using USSD 3 8 KVM Virtualization KVM is a virtualisation module that allows administrators using our routers to host a large range of virtual machines KVM is now supported on some MediaFast ContentHub routers Click here for the full instructions on how to set up KVM ...

Страница 71: ...feature go to https Device s IP cgi bin MANGA support cgi 3 11 Wi Fi Air Monitoring Pepwave routers support Wi Fi Air Monitoring Mode which used to troubleshoot remotely and proactively monitor Wi Fi and WAN performance The report can be viewed under InControl 2 Reports AirProbe Reports after enabling Wi Fi Air Monitoring Note To enable this feature go to https Device s IP cgi bin MANGA support cg...

Страница 72: ...ter installed with the TCP IP network protocol and a supported web browser Supported browsers include Microsoft Internet Explorer 11 or above Mozilla Firefox 24 or above Apple Safari 7 or above and Google Chrome 18 or above 4 2 Constructing the Network At a high level construct the network according to the following steps 1 With an Ethernet cable connect a computer to one of the LAN ports on the P...

Страница 73: ...fer to the following setup procedures LAN configuration For basic configuration refer to Section 8 Connecting to the Web Admin Interface For advanced configuration go to Section 9 Configuring the LAN Interface s WAN configuration For basic configuration refer to Section 8 Connecting to the Web Admin Interface For advanced configuration go to Section 9 2 Captive Portal ...

Страница 74: ... x 20mm head diameter 6mm head thickness 2 4mm The Pepwave MAX BR1 requires four screws for wall mounting 5 2 Car Mount The Pepwave MAX700 HD2 can be mounted in a vehicle using the included mounting brackets Place the mounting brackets by the two sides and screw them onto the device 5 3 IP67 Installation Guide Installation instructions for IP67 devices can be found here http download peplink com m...

Страница 75: ...5 4 PDX Accessory Kit Installation Guide 5 4 1 Battery Set appearance Step 2 Plug power cable into the socket ...

Страница 76: ...5 4 2 SFE DUO Set appearance ...

Страница 77: ... STEP 2 Assemble bracket to the device ...

Страница 78: ... STEP 3 Assemble SMA connectors to the bracket ...

Страница 79: ... STEP 4 Lock the SFE Duo set in the slot with 2 pcs M3 screws ...

Страница 80: ... STEP 5 Connect DC power ETH port STEP 6 Lock the slot cover with 4 pcs M3 screws ...

Страница 81: ......

Страница 82: ... http 192 168 50 1 This is the default LAN IP address for Pepwave routers 3 Enter the following to access the web admin interface Username admin Password admin This is the default username and password for Pepwave routers You must change the default password on the first successful logon Password requirements are A minimum of 10 lower AND upper case characters including at least 1 number When HTTP...

Страница 83: ...ion on setting up these connections please refer to Sections 8 and 9 Device Information displays details about the device including model name firmware version and uptime For further information please refer to Section 22 Important Note Configuration changes e g WAN LAN admin settings etc will take effect only after clicking the Save button at the bottom of each page The Apply Changes button cause...

Страница 84: ... is a subscription basis SpeedFusion Cloud license can be purchased at https store peplink com Cloud Solutions SpeedFusion Cloud Service 7 1 Activate SpeedFusion Cloud Service You are entitled to a 30 day free period with 100GB of SpeedFusion usage upon activation of the SpeedFusion Cloud service This offer is limited to once per device To get your activation key please visit SpeedFusion Cloud Go ...

Страница 85: ...elect the devices that you wish to activate SpeedFusion Cloud on and Click ACTIVATE From System Features Add ons paste the license key into the window and click on Activate once you have received the license key ...

Страница 86: ......

Страница 87: ...Enable SpeedFusion Cloud Enable SpeedFusion Cloud from SpeedFusion Cloud Choose Cloud Location Choose Automatic Click on the green tick button to confirm the change Click on Apply Changes to save the change ...

Страница 88: ...By default the router will build a SpeedFusion tunnel to the SpeedFusion Cloud ...

Страница 89: ......

Страница 90: ...ice like video streaming or VOIP a WAN Smoothing sub tunnel can be created Navigate to Speedfusion Cloud Choose a cloud location SFC A Speedfusion tunnel configuration window will pop out Click on the sign to create the WAN Smoothing sub tunnel ...

Страница 91: ......

Страница 92: ...Click on Save and Apply Changes to save the configuration Now the router has 2 Speedfusion tunnels to the Speedfusion Cloud ...

Страница 93: ...Create an outbound policy to steer the internet traffic to go into Speedfusion Cloud Please go to Advanced Outbound Policy click on Add Rule to create a new outbound policy ...

Страница 94: ...7 3 Connect Clients to Cloud SpeedFusion Cloud provides a convenient way to route the LAN client to the cloud From SpeedFusion Cloud Connect Clients to Cloud ...

Страница 95: ...ick Save Apply Changes 7 4 Link Wi Fi to Cloud SpeedFusion Cloud provides a convenient way to route the Wi Fi client to the cloud from SpeedFusion Cloud Link Wi Fi to Cloud This option is available for Balance 20X Balance 30 Pro and Balance One ...

Страница 96: ...SID for SpeedFusion Cloud The new SSID will inherit all settings from one of the existing SSIDs including the Security Policy Then click Save follow by Apply Changes SpeedFusion Cloud SSID will be shown on Dashboard ...

Страница 97: ...7 5 Optimize Cloud Application Optimize Cloud Application allows you to route Internet traffic to SpeedFusion Cloud based on the application Go to SpeedFusion Cloud Optimize Cloud Application ...

Страница 98: ...eted You can find which settings are using the VLAN by hovering over the grey X Alternatively a red X means that there are no settings using the VLAN You can delete that VLAN by clicking the red X Clicking on any of the existing LAN interfaces or creating a new one will show the following IP Settings IP Address The IP address and subnet mask of the Pepwave router on the LAN Network Settings Name E...

Страница 99: ...ee Protocol Click the box will enable STP for this layer 2 profile bridge Override IP Address when bridge connected Select Do not override if the LAN IP address and local DHCP server should remain unchanged after the Layer 2 PepVPN is up If you choose to override IP address when the VPN is connected the device will not act as a router and most Layer 3 routing functions will cease to work DHCP Opti...

Страница 100: ...HCP clients If Assign DNS server automatically is selected the Pepwave router s built in DNS server address i e LAN IP address will be offered WINS Servers This option allows you to optionally specify a Windows Internet Name Service WINS server You may choose to use the built in WINS server or external WINS servers When this unit is connected using SpeedFusionTM other VPN peers can share this unit...

Страница 101: ...ed This is the port speed of the LAN interface It should be set to the same speed as the connected device to avoid port negotiation problems When a static speed is set you may choose whether to advertise its speed to the peer device Auto is selected by default You can choose not to advertise the port speed if the port has difficulty negotiating with the peer device Static Route Settings Static Rou...

Страница 102: ...esponding unique Virtual IP Address for NAT Traffic originating from the Local Network to remote connections will be SNAT ed and behave like coming from the defined Virtual Network While traffic initiated by remote peers to the Virtual Network will be DNAT ed accordingly Many to One NAT The subnet range defined in Local Network will be mapped to a single Virtual IP Address for NAT Traffic can only...

Страница 103: ...frequently updated DNS records By default DNS Caching is disabled Include Google Public DNS Servers When this option is enabled the DNS proxy server will also forward DNS requests to Google s Public DNS Servers in addition to the DNS servers defined in each WAN This could increase the DNS service s availability This setting is disabled by default Local DNS Records DNS Resolvers A Check the box to ...

Страница 104: ...njour forwarding Apple s zero configuration networking protocol Once VLAN configuration is complete click Save to store your changes Bonjour Forwarding Settings Enable Check this box to turn on Bonjour forwarding Bonjour Service Choose Service and Client networks from the drop down menus and then click to add the networks To delete an existing Bonjour listing click ...

Страница 105: ... will be automatically updated When drop in mode is enabled the LAN and the WAN for drop in mode ports will be bridged Traffic between the LAN hosts and WAN router will be forwarded between the devices In this case the hosts on both sides will not notice any IP or MAC address changes After successfully setting up the Pepwave MAX as part of the network using drop in mode it will depending on model ...

Страница 106: ...the passthrough IP address will be used to connect to WAN hosts email notification remote syslog etc The MAX will listen for this IP address when WAN hosts access services provided by the MAX web admin access from the WAN DNS server requests etc To connect to hosts on the LAN email notification remote syslog etc the default gateway address will be used The MAX will listen for this IP address when ...

Страница 107: ...Default Gateway WAN DNS Servers Enter the selected WAN s corresponding DNS server IP addresses To add a new LAN click the New LAN button To change LAN settings click the name of the LAN to change under the LAN heading The following settings are displayed when creating a new LAN or editing an existing LAN IP Settings IP Address Subnet Mask Enter the Pepwave router s IP address and subnet mask value...

Страница 108: ...out which an IP address of a DHCP client remains valid Upon expiration of Lease Time the assigned IP address will no longer be valid and the IP address assignment must be renewed DNS Servers This option allows you to input the DNS server addresses to be offered to DHCP clients If Assign DNS server automatically is selected the Pepwave router s built in DNS server address i e LAN IP address will be...

Страница 109: ...IP addresses on the LAN are identified by their MAC addresses The fixed IP address assignment is displayed as a cross reference list between the computers names MAC addresses and fixed IP addresses Section 22 3 DHCP Relay Settings Enable Check this box to turn on DHCP relay Click the icon to disable DHCP relay DHCP Server IP Address Enter the IP addresses of one or two DHCP servers in the provided...

Страница 110: ...ort settings navigate to Network Port Settings On this screen you can enable specific ports as well as determine the speed of the LAN ports whether each port is a trunk or access port can well as which VLAN each link belongs to if any ...

Страница 111: ...L in this field To reset the URL to factory settings click Default Access Mode Click Open Access to allow clients to freely access your router Click User Authentication to force your clients to authenticate before accessing your router RADIUS Server This authenticates your clients through a RADIUS server After selecting this option you will see the following fields Fill in the necessary informatio...

Страница 112: ...as been reached Allowed Networks Add networks that can bypass the captive Portal in this field To whitelist a network enter the domain name IP address here and click To delete an existing network from the list of allowed networks click the button next to the listing Allowed Clients Add MAC address and or IP addresses for client devices that are allowed to bypass the Captive Portal Clients accessin...

Страница 113: ...ave any additional messages for your users enter them in this field Terms Conditions If you would like to use your own set of terms and conditions please enter them here If left empty the built in portal will display the default terms and conditions Custom Landing Page Fill in this field to redirect clients to an external URL ...

Страница 114: ...priority and so on and drop it by releasing the mouse button To able a particular WAN connection drag on the appropriate WAN by holding the left mouse button move it the Disabled row and drop it by releasing the mouse button You can also set priorities on the Dashboard Click the Details button in the corresponding row to modify the connection setting Important Note Connection details will be chang...

Страница 115: ...ng the target IP addresses or host names where ICMP Ping packets will be sent to for health check If the box Use first two DNS servers as PING Hosts is checked the first two DNS servers will be the ping targets for checking the connection healthiness If the box is not checked the field Host 1 must be filled and the field Host 2 is optional The connection is considered to be up if ping responses ar...

Страница 116: ... and 95 of the monthly allowance If the box Disconnect when usage hits 100 of monthly allowance is checked this WAN connection will be disconnected automatically when the usage hits the monthly allowance It will not resume unless this option has been turned off or the usage has been reset when a new billing cycle starts Start Day This option allows you to select which day of the month a billing cy...

Страница 117: ... com dyndns org no ip org tzo com DNS O Matic Select Disabled to disable this feature See Section 9 5 for configuration details 9 1 1 DHCP Connection There are four possible connection methods 1 DHCP 2 Static IP 3 PPPoE 4 L2TP 5 GRE The DHCP connection method is suitable if the ISP provides an IP address automatically using DHCP e g satellite modem WiMAX modem cable Metro Ethernet etc ...

Страница 118: ...lows you to configure the management IP address for the DHCP WAN connection DNS Servers Each ISP may provide a set of DNS servers for DNS lookups This setting specifies the DNS Domain Name System servers to be used when a DNS lookup is routed through this connection Selecting Obtain DNS server address automatically results in the DNS servers being assigned by the WAN DHCP server to be used for out...

Страница 119: ...t from Backup WANs If this is checked the connection will be working independent from other Backup WAN connections Those in Backup Priority will ignore the status of this WAN connection and will be used when none of the other higher priority connections are available Standby State This option allows you to choose whether to remain connected when this WAN connection is no longer in the highest prio...

Страница 120: ...he maximum download speed Default weight control for outbound traffic will be adjusted according to this value 9 1 2 Static IP Connection The static IP connection method is suitable if your ISP provides a static IP address to connect directly ...

Страница 121: ...termined by and can be obtained from the ISP DNS Servers Each ISP may provide a set of DNS servers for DNS lookups This setting specifies the DNS Domain Name System servers to be used when a DNS lookup is routed through this connection Selecting Obtain DNS server address automatically results in the DNS servers being assigned by the WAN DHCP server to be used for outbound DNS lookups over the conn...

Страница 122: ... the help icon in this field you can display the IP Forwarding option if your network requires it PPPoE Username Password Enter the required information in these fields in order to connect via PPPoE to the ISP The parameter values are determined by and can be obtained from the ISP Confirm PPPoE Password Verify your password by entering it again in this field Service Name Optional Service name is p...

Страница 123: ...utomatically results in the DNS servers being assigned by the WAN DHCP server to be used for outbound DNS lookups over the connection The DNS servers are obtained along with the WAN IP address assigned from the DHCP server When Use the following DNS server address es is selected you may enter custom DNS server addresses for this WAN connection into the DNS Server 1 and DNS Server 2 fields 9 1 4 L2...

Страница 124: ...our password by entering it again in this field Server IP Address Host L2TP server address is a parameter which is provided by your ISP Note Leave this field blank unless it is provided by your ISP Address Type Your ISP will also indicate whether the server IP address is Dynamic or Static Please click the appropriate value DNS Servers Each ISP may provide a set of DNS servers for DNS lookups This ...

Страница 125: ...tion into the DNS server 1 and DNS server 2 fields 9 1 5 GRE Connection This connection method is suitable if your ISP provides a static WAN IP and Tunnel IP via GRE L2TP Settings Routing Mode NAT allows substituting the real address in a packet with a mapped address that is routable on the destination network By clicking the help icon in this field you can display the IP Forwarding option if your...

Страница 126: ... you to enter the IP address of the remote tunnel for the GRE tunnel connection DNS Servers Each ISP may provide a set of DNS servers for DNS lookups This setting specifies the DNS Domain Name System servers to be used when a DNS lookup is routed through this connection Selecting Obtain DNS server address automatically results in the DNS servers assigned by the PPPoE server to be used for outbound...

Страница 127: ... only ICCID This is a unique number assigned to a SIM card used in a cellular device MEID Some Pepwave routers support both HSPA and EV DO For Sprint or Verizon Wireless EV DO users a unique MEID identifier code in hexadecimal format is used by the carrier to associate the EV DO device with the user This information is presented in hex and decimal format IMEI This is the unique ID for identifying ...

Страница 128: ...tion The DNS servers are obtained along with the WAN IP address assigned by the DHCP server When Use the following DNS server address es is selected you may enter custom DNS server addresses for this WAN connection into the DNS server 1 and DNS server 2 fields Independent from Backup WANs If this is checked the connection will be working independent from other Backup WAN connections Those in Backu...

Страница 129: ...ar Settings SIM Card IIndicate which SIM card this cellular WAN will use Only applies to cellular WAN with redundant SIM cards For routers that support the SIM Injector you may select the Use Remote SIM Only to provision a SIM from a SIM Injector Further details on the SIM Injector found is available here https www peplink com products sim injector ...

Страница 130: ...rupt the connectivity for a short while Band Selection When set to Auto band selection allows for automatically connecting to available supported bands frequencies When set to Manual you can manually select the bands frequencies the SIM will connect to Data Roaming This checkbox enables data roaming on this particular SIM card When data roaming is enabled this option allows you to select in which ...

Страница 131: ...ed you will be notified by email when usage hits 75 and 95 of the monthly allowance If Disconnect when usage hits 100 of monthly allowance is checked this WAN connection will be disconnected automatically when the usage hits the monthly allowance It will not resume connection unless this option has been turned off or the usage has been reset when a new billing cycle starts Start Day This option al...

Страница 132: ...test will be treated as failed Health Check Interval This is the time interval between each health check test Health Check Retries This is the number of consecutive check failures before treating a connection as down Recovery Retries This is the number of responses required after a health check failure before treating a connection as up again Dynamic DNS Settings Dynamic DNS Service Provider This ...

Страница 133: ...tion Settings WAN Connection Name Enter a name to represent this WAN connection Operating Schedule Click the drop down menu to apply a time schedule to this interface Independent from Backup WANs If this is checked the connection will be working independent from other Backup WAN connections Those in Backup Priority will ignore the status of this WAN connection and will be used when none of the oth...

Страница 134: ...l width for this Wi Fi WAN 20MHz will have greater support for older devices using 2 4Ghz while 40MHz is appropriate for networks with newer devices that connect using 5Ghz Channel Selection Determine whether the channel will be automatically selected If you select custom the following table will appear Data Rate Selecting Auto will enable the router to automatically determine the best data rate w...

Страница 135: ... automatically when the usage hits the monthly allowance It will not resume connection unless this option has been turned off or the usage has been reset when a new billing cycle starts Start Day This option allows you to define which day of the month each billing cycle begins Monthly Allowance This field is for defining the maximum bandwidth usage allowed for the WAN connection each month Health ...

Страница 136: ... be issued to test connectivity with target DNS servers The connection will be treated as up if DNS responses are received from one or both of the servers regardless of whether the result was positive or negative Health Check DNS Servers This field allows you to specify two DNS hosts IP addresses with which connectivity is to be tested via DNS Lookup If Use first two DNS servers as Health Check DN...

Страница 137: ...seconds for ping DNS lookup requests The default timeout is 5 seconds Health Check Interval This setting specifies the time interval in seconds between ping or DNS lookup requests The default health check interval is 5 seconds Health Check Retries This setting specifies the number of consecutive ping DNS lookup timeouts after which the Pepwave MAX will treat the corresponding WAN connection as dow...

Страница 138: ... This setting specifies a list of hostnames or domains to be associated with the public Internet IP address of the WAN connection Important Note In order to use dynamic DNS services appropriate hostname registration s as well as a valid account with a supported dynamic DNS service provider are required A dynamic DNS update is performed whenever a WAN s IP address is changed such as when an IP is c...

Страница 139: ...to the one shown below Wi Fi Connection Profile Settings Type Select whether the network will connect automatically or manually Network Name SSID Enter a name to represent this Wi Fi connection Security This option allows you to select which security policy is used for this wireless network Available options Open WPA3 Personal AES CCMP WPA2 WPA3 Personal AES CCMP WPA2 Personal AES CCMP WPA2 Enterp...

Страница 140: ...l be issued to test the connectivity with a configurable target IP address or hostname A WAN connection is considered as up if ping responses are received from either one or both of the ping hosts PING Hosts This setting specifies IP addresses or hostnames with which connectivity is to be tested via ICMP ping If Use first two DNS servers as Ping Hosts is checked the target ping host will be the fi...

Страница 141: ...it Health Check Settings URL1 The URL will be retrieved when performing an HTTP health check When String to Match is left blank a health check will pass if the HTTP return code is between 200 and 299 Note HTTP redirection codes 301 or 302 are treated as failures When String to Match is filled a health check will pass if the HTTP return code is between 200 and 299 and if the HTTP response content c...

Страница 142: ...Settings Pepwave routers are capable of registering the domain name relationships to dynamic DNS service providers Through registration with dynamic DNS service provider s the default public Internet IP address of each WAN connection can be associated with a host name With dynamic DNS service enabled for a WAN connection you can connect to your WAN s IP address from the external even if its IP add...

Страница 143: ...is field allows you to specify a list of host names or domains to be associated with the public Internet IP address of the WAN connection If you need to enter more than one host use a carriage return to separate them Important Note In order to use dynamic DNS services appropriate host name registration s and a valid account with a supported dynamic DNS service provider are required A dynamic DNS u...

Страница 144: ...w If a North American region is selected RF channels 1 to 11 will be available and the maximum transmission power will be 26 dBm 400 mW If European region is selected RF channels 1 to 13 will be available The maximum transmission power will be 20 dBm 100 mW Note Users are required to choose an option suitable to local laws and regulations Preferred Frequency Indicate the preferred frequency to use...

Страница 145: ... will be utilized Channel 1 2 412 GHz is selected by default Auto Channel Update Indicate the time of day at which update automatic channel selection Output Power This option is for specifying the transmission output power for the Wi Fi AP There are 4 relative power levels available Max High Mid and Low The actual output power will be bound by the regulatory limits of the selected country Client S...

Страница 146: ...is for setting the time interval between each beacon By default 100ms is selected DTIM A This field allows you to set the frequency for the beacon to include delivery traffic indication messages The interval is measured in milliseconds The default value is set to 1 ms RTS Threshold A The RTS Request to Clear threshold determines the level of connection required before the AP starts sending data Th...

Страница 147: ... admin portal Admin Password Determines the password for the web admin portal on external AP Wi Fi WAN settings can be configured at Advanced Wi Fi Settings or Advanced Wi Fi WAN or some models Wi Fi WAN Settings Channel Width Available options are 20 40 MHz and 20 MHz Default is 20 40 MHz which allows both widths to be used simultaneously Bit Rate This option allows you to select a specific bit r...

Страница 148: ...ol MediaFast Enable Click the checkbox to enable MediaFast content caching Domains IP Addresses Choose to Cache on all domains or enter domain names and then choose either Whitelist cache the specified domains only or Blacklist do not cache the specified domains Source IP Subnet This setting allows caching to be enabled on custom subnets only If Any is selected then caching will apply to all subne...

Страница 149: ...allation for mediafast https caching Cache Control Content Type Check these boxes to cache the listed content types or leave boxes unchecked to disable caching for the listed types Cache Lifetime Settings Enter a file extension such as JPG or DOC Then enter a lifetime in days to specify how long files with that extension will be cached Add or delete entries using the controls on the right 11 2 Sch...

Страница 150: ...ue that is too low might indicate an incomplete download or incorrectly specified download target while a value that is too long could mean a download with an incorrectly specified target or stop time Result Last Download Check this field to ensure that the most recent download file size is within the expected range A value that is too low might indicate an incomplete download or incorrectly speci...

Страница 151: ...sted information to create your schedule Clear Web Cache To clear all cached content click this button Note that this action cannot be undone Clear Statistics To clear all prefetch and status page statistics click this button ...

Страница 152: ...11 3 Viewing MediaFast Statistics To get details on storage and bandwidth usage select Status MediaFast ...

Страница 153: ...igure storage To access ContentHub navigate to Advanced ContentHub and check the Enable box On an external server configure content a website or application that will be synced to the ContentHub For example an html5 website To configure a website or application as content follow the steps below Configure a website for ContentHub This option allows you to sync a website to the Pepwave router This w...

Страница 154: ...Hub to use as the domain name for client access such as http mytest com Method Only applicable for Application type content Choose between sync or file upload Source Enter the details of the server that the content will be downloaded from Enter credentials under Username and Password Period This field determines how often the router will search for updates to the source content Bandwidth Limit Set...

Страница 155: ...To access the content open a browser in the MFA s client and enter the domain details that were configured earlier such as http mytest com ...

Страница 156: ...application from the router itself by using one of the supported frameworks below Python version 2 7 12 Ruby version 2 3 3 Node js version 6 9 2 Install the desired framework under Package Manager as shown below After installing the framework change the Type to Application and configure the website ...

Страница 157: ...elow 1 Implement two bash script files start sh and stop sh in the root folder to start and stop your application The MediaFast router will only execute start sh and stop sh when the corresponding website is enabled and disabled respectively 2 Compress the application files and the bash script to tar gz format 3 Upload this tar file to the router ...

Страница 158: ...epwave up to the point of creating a running Docker Container Information about Docker can be found on the Docker Documentation site https docs docker com 2 This will allow you to run a file sharing platform ownCloud a web server WordPress Joomla a learning platform Moodle or a visualisation tool for viewing large scale data Kibana When creating a new Docker Container the Pepwave router will searc...

Страница 159: ...ns refer to our knowledge base articles 1 How to install a Virtual Machine on Peplink Pepwave MediaFast ContentHub Routers https forum peplink com t how to install a virtual machine into peplinkpepwave mediafastcontenthub routers 2 How to Install Virtual Machine with USB storage on Peplink Pepwave MediaFast ContentHub Routers https forum peplink com t how to install virtual machine with usb storag...

Страница 160: ...nd network congestion at one or more WANs other WANs can be used to continue carrying the network traffic Different models of our SD WAN routers have different numbers of site to site connections allowed End users who need to have more site to site connections can purchase a SpeedFusion license to increase the number of site to site connections allowed Pepwave routers can aggregate all WAN connect...

Страница 161: ... configure navigate to Advanced SpeedFusion or Advanced PepVPN and click the New Profile button to create a new VPN profile you may have to first save the displayed default profile in order to access the New Profile button Each profile specifies the settings for making VPN connection with one remote Pepwave or Peplink device Note that available settings vary by model A list of defined SpeedFusion ...

Страница 162: ...nique peer ID number in the Remote ID field Remote ID Pre shared Key This optional field becomes available when Remote ID Pre shared Key is selected as the Pepwave router s VPN Authentication method as explained above Pre shared Key defines the pre shared key used for this particular VPN connection The VPN connection s session key will be further protected by the pre shared key The connection will...

Страница 163: ...or connection from the remote peer Therefore at least one of the two VPN peers must specify this value Otherwise VPN connections cannot be established Cost Define path cost for this profile OSPF will determine the best route through the network using the assigned cost Default 10 Data Port This field is used to specify a UDP port number for transporting outgoing VPN data If Default is selected UDP ...

Страница 164: ...AN connections with the highest priority will be used To enable asymmetric connections connection mapping to remote WANs cut off latency and packet loss suspension time click the button Send All Traffic To This feature allows you to redirect all traffic to a specified PepVPN connection Click the button to select your connection and the following menu will appear You could also specify a DNS server...

Страница 165: ...ibility Determine the level of backward compatibility needed for PepVPN tunnels The use of the Latest setting is recommended as it will improve the performance and resilience of SpeedFusion connections Link Failure Detection Time The bonded VPN can detect routing failures on the path between two sites over each WAN connection Failed WAN connections will not be used to route VPN traffic Health chec...

Страница 166: ...need to add firewall rules for these ports and protocols to allow inbound and outbound traffic to pass through the firewall Tip Want to know more about VPN sub second session failover Visit our YouTube Channel for a video tutorial http youtu be TLQgdpPSY88 15 2 The Pepwave Router Behind a NAT Router Pepwave routers support establishing SpeedFusionTM over WAN connections which are behind a NAT netw...

Страница 167: ...connected to Router B are NAT d In this case the Peer IP Addresses Host Names field for Router B should be filled with all of Router A s hostnames or public IP addresses i e 212 1 1 1 212 2 2 2 and 212 3 3 3 and the field in Router A can be left blank The two NAT routers on WAN1 and WAN3 connected to Router A should inbound port forward TCP port 32015 to Router A so that all WANs will be utilized ...

Страница 168: ... Must Be Unique Among VPN Peers The entire interconnected SpeedFusionTM network is a single non NAT IP network Avoid duplicating subnets in your sites to prevent connectivity problems when accessing those subnets ...

Страница 169: ...6 1 IPsec VPN Settings Many Pepwave products can make multiple IPsec VPN connections with Peplink Pepwave Cisco and Juniper routers Note that all LAN subnets and the subnets behind them must be unique Otherwise VPN members will not be able to access each other All data can be routed over the VPN with a selection of encryption standards such as 3DES AES 128 and AES 256 To configure IPsec VPN on Pep...

Страница 170: ......

Страница 171: ... NAT Network has the same size for example policy 192 168 50 0 24 172 16 1 0 24 will translate the local IP address 192 168 50 10 to 172 16 1 10 and 192 168 50 20 to 172 16 1 20 This is a bidirectional mapping which means clients in remote site can initiate connection to the local clients using the mapped address too Many to One NAT policy if the defined NAT Network on the right hand side is an IP...

Страница 172: ...an group used within IKE This allows two parties to establish a shared secret over an insecure communications channel The larger the group number the higher the security Group 2 1024 bit is the default value Group 5 1536 bit is the alternative option Phase 1 SA Lifetime This setting specifies the lifetime limit of this Phase 1 Security Association By default it is set at 3600 seconds Phase 2 ESP P...

Страница 173: ...layer protocols inside virtual point to point links over an Internet Protocol network A GRE tunnel is similar to IPSec or PepVPN To configure a GRE Tunnel navigate to Advanced GRE Tunnel Click the New Profile button to create new GRE tunnel profiles that establish tunnel connections to remote tunnel endpoints via available WAN connections To edit the profiles click on its associated connection nam...

Страница 174: ...s for entering the remote GRE s IP address Tunnel Local IP Address This field is for specifying the tunnel source IP address Tunnel Remote IP Address This field is for specifying the tunnel destination IP address Tunnel Subnet Mask This field is to select the subnet mask that is to be used for the GRE tunnel Connection Select the appropriate WAN connection from the drop down menu Remote Networks I...

Страница 175: ...te Outbound policy is applied only when more than one WAN connection is active The settings for managing and load balancing outbound traffic are located at Advanced Outbound Policy or Advanced PepVPN depending on the model 17 1 Outbound Policy Outbound policies for managing and load balancing outbound traffic are located at ...

Страница 176: ...ibility Normal Application Compatibility Outbound traffic from a source LAN device to the same destination Internet IP address will be routed through the same WAN connection persistently regardless of protocol This option provides high compatibility to most applications and users still benefit from WAN link load balancing when multiple Internet servers are accessed Custom Outbound traffic behavior...

Страница 177: ...e bottom most rule is Default Edit this rule to change the device s default manner of controlling outbound traffic for all connections that do not match any of the rules above it Under the Service heading click Default to change these settings To rearrange the priority of outbound rules drag and drop them into the desired sequence ...

Страница 178: ...ed as the Default Rule You can select Custom to change the algorithm to be used Please refer to the upcoming sections for the details on the available algorithms To create a custom rule click Add Rule at the bottom of the table ...

Страница 179: ... the rule When Enable is unchecked the rule does not take effect the Pepwave router disregards the other parameters of the rule Click the drop down menu next to the checkbox to apply a time schedule to this custom rule Source This setting specifies the source IP Address IP Network MAC Address or Grouped Network for traffic that matches the rule Destination This setting specifies the destination IP...

Страница 180: ...he following protocols can be specified Any TCP UDP IP DSCP Alternatively the Protocol Selection Tool drop down menu can be used to automatically fill in the protocol and port number of common Internet services e g HTTP HTTPS etc After selecting an item from the Protocol Selection Tool drop down menu the protocol and port number remains manually modifiable Algorithm This setting specifies the beha...

Страница 181: ...ms By default this setting is disabled In this case existing IP sessions will not be terminated or affected when any other WAN connection is recovered When this setting is enabled existing IP sessions may be terminated when another WAN connection is recovered such that only the preferred healthy WAN connection s is used at any point in time 17 2 1 Algorithm Weighted Balance This setting specifies ...

Страница 182: ...security concern is that an IP address change during a session may be the result of an unauthorized intrusion attempt Therefore to prevent damages from the potential intrusion the session is terminated upon the detection of an IP address change Pepwave routers can be configured to distribute data traffic across multiple WAN connections Also the Internet IP depends on the WAN connections over which...

Страница 183: ... Bandwidth which is specified in the WAN settings page If you choose Custom you can customize the weight of each WAN manually by using the sliders 17 2 3 Algorithm Enforced This setting specifies the WAN connection usage to be applied on the specified IP protocol and port This setting is applicable only when Algorithm is set to Enforced Matching traffic will be routed through the specified WAN con...

Страница 184: ...s 17 2 5 Algorithm Overflow The traffic matching this rule will be routed through the healthy WAN connection that has the highest priority and is not in full load When this connection gets saturated new sessions will be routed to the next healthy WAN connection that is not in full load Drag and drop to specify the order of WAN connections to be used for routing traffic Only the highest priority he...

Страница 185: ...the lowest latency Latency checking packets are issued periodically to a nearby router of each WAN connection to determine its latency value The latency of a WAN is the packet round trip time of the WAN connection Additional network usage may be incurred as a result Tip The roundtrip time of a 6M down 640k uplink can be higher than that of a 2M down 2M up link because the overall round trip time i...

Страница 186: ...eedFusionTM routes learned from remote VPN peers By default this bar is on the top of all custom rules This position means that traffic for remote VPN subnets will be routed to the corresponding VPN peer You can create custom Priority or Enforced rules and move them above the bar to override the SpeedFusionTM routes Upon disabling Expert Mode all rules above the bar will be removed ...

Страница 187: ...r disregards the other parameters of the rule Service Name This setting identifies the service to the system administrator Valid values for this setting consist of only alphanumeric and underscore _ characters IP Protocol The IP Protocol setting along with the Port setting specifies the protocol of the service as TCP UDP ICMP or IP Traffic that is received by the Pepwave router via the specified p...

Страница 188: ...rotocol set to TCP and Port set to Port Range and Service Ports 80 88 TCP traffic received on ports 80 through 88 is forwarded to the configured servers via the respective ports Port Mapping traffic that is received by Pepwave router via the specified protocol at the specified port is forwarded via a different port to the servers specified by the Servers setting For example with IP Protocol set to...

Страница 189: ...port of all WAN connections default IP address will be forwarded Check the corresponding box es to enable UPnP and or NAT PMP Enable these features only if you trust the computers connected to the LAN ports When the options are enabled a table listing all the forwarded ports under these two protocols can be found at Status UPnP NAT PMP ...

Страница 190: ...elow in order to facilitate inbound and outbound traffic This option is only available when IP Address is selected Range The IP range is a contiguous group of private IP addresses used by the LAN host The system maps these addresses to a number of public IP addresses specified below to facilitate outbound traffic This option is only available when IP Range is selected Network The IP network refers...

Страница 191: ...uld be used when an IP connection is made from a LAN host to the Internet Each LAN host in an IP range or IP network will be evenly mapped to one of each selected WAN s IP addresses for better IP address utilization in a persistent manner for better application compatibility Note that if you do not want to use a specific WAN for outgoing accesses you should still choose default here then customize...

Страница 192: ...the top of the table and have higher precedence larger and less specific subnets are placed towards the bottom Add Edit User Group Subnet IP Address From the drop down menu choose whether you are going to define the client s by an IP Address or a Subnet If IP Address is selected enter a name defined in DHCP reservation table or a LAN client s IP address If Subnet is selected enter a subnet address...

Страница 193: ...any Pepwave routers you can choose whether to apply the same prioritization settings to all user groups or customize the settings for each group Three application priority levels can be set High Normal and Low Pepwave routers can detect various application traffic types by inspecting the packet content Select an application by choosing a supported application or by defining a custom application ma...

Страница 194: ...port number and DSCP value 20 3 3 DSL Cable Optimization DSL cable based WAN connections have lower upload bandwidth and higher download bandwidth When a DSL cable circuit s uplink is congested the download bandwidth will be affected Users will not be able to download data at full speed until the uplink becomes less congested DSL Cable Optimization can relieve such an issue When it is enabled the ...

Страница 195: ...fensive websites and or other inappropriate uses The firewall functionality of Pepwave routers supports the selective filtering of data traffic in both directions Outbound LAN to WAN Inbound WAN to LAN Internal Network VLAN to VLAN The firewall also supports the following functionality Intrusion detection and DoS prevention Web blocking With SpeedFusionTM enabled the firewall rules also apply to V...

Страница 196: ...firewall settings are located at Advanced Firewall Access Rules Outbound Firewall Rules Click Add Rule to display the following screen Inbound firewall settings are located at Advanced Firewall Access Rules Inbound Firewall Rules Click Add Rule to display the following screen ...

Страница 197: ...nal Network firewall settings are located at Advanced Firewall Access Rules Internal Network Firewall Rules Click Add Rule to display the following window Inbound Outbound Internal Network Firewall Settings ...

Страница 198: ...to automatically fill in the protocol and port number of common Internet services e g HTTP HTTPS etc After selecting an item from the Protocol Selection Tool drop down menu the protocol and port number remains manually modifiable Source IP Port This specifies the source IP address es and port number s to be matched for the firewall rule A single address or a network can be specified as the Source ...

Страница 199: ...s LEN Packet length PROTO Protocol SPT Source port DPT Destination port Click Save to store your changes To create an additional firewall rule click Add Rule and repeat the above steps To change a rule s priority simply drag and drop the rule Hold the left mouse button on the rule Move it to the desired position Drop it by releasing the mouse button Rules are matched from top to bottom If a connec...

Страница 200: ...c 21 1 3 Intrusion Detection and DoS Prevention When this feature is enabled the Pepwave router will detect and prevent the following kinds of intrusions and denial of service attacks Port scan o NMAP FIN URG PSH o Xmas tree o Another Xmas tree o Null scan o SYN RST o SYN FIN SYN flood prevention Ping flood attack prevention ...

Страница 201: ...ose applications to be blocked from LAN PPTP PepVPN peer clients access except for those on the Exempted User Groups or Exempted Subnets defined below 21 2 2 Web Blocking Defines website domain names to be blocked from LAN PPTP PepVPN peer clients access ...

Страница 202: ...Exceptions can be added using the instructions in Sections 20 1 3 2 and 20 1 3 3 You may enter the wild card at the end of a domain name to block any web site with a host name having the domain name in the middle For example If you enter foobar then www foobar com www foobar co jp or foobar co uk will be blocked Placing the wild card in any other position is not supported The Pepwave MAX will insp...

Страница 203: ...to reach the following menu OSPF Router ID This field determines the ID of the router By default this is specified as the WAN IP address If you want to specify your own ID enter it into the Custom field Area This is an overview of the OSPF areas that you have defined Clicking on the name under Area allows you to configure the connection To define a new area click Add To delete an existing area cli...

Страница 204: ...Link Type Choose the type of network that this area will use Authentication If an authentication method is used select one from this drop down menu Available options are MD5 and Text Authentication key s may be input next to the drop down menu after selecting an authentication method Interfaces Select the interface s that this area will use to listen to and deliver OSPF packets ...

Страница 205: ...ach other Received PepVPN routes will not be forwarded to other PepVPN peers to reduce bandwidth consumption Network Advertising Networks to be advertised over OSPF RIPv2 If no network is selected all LAN VLAN networks will be advertised by default Static Route Advertising Enabling OSPF RIPv2 Route Advertising allows it to advertise LAN static routes over OSPF RIPv2 Static routes on the Excluded N...

Страница 206: ...or s ASN Multihop TTL This field determines the Time to live TTL of BGP packets Leave this field blank if the BGP neighbor is directly connected otherwise you must specify a TTL value This option should be used if the configured Neighbor s IP address does not match the selected Interface s network subnets The TTL value must be between 2 to 255 Password Optional Assign a password for MD5 authentica...

Страница 207: ... Detection for path failure All directly connected Neighbors that use the same physical interface share the same BFD settings All mulithop Neighbors share the same multihop BFD settings You can configure BFD settings in the BGP profile listing page after this option is enabled Network Advertising Select the Networks that will be advertised to the BGP Neighbor Static Route Advertising Enable this o...

Страница 208: ...utes in Restricted Networks will be rejected routes not in the list will be accepted Restricted Networks This field specifies the network s in the route import entry Exact Match When this box is checked only routes with the same Network and Subnet Mask will be filtered Otherwise routes within the Networks and Subnets will be filtered Filter Mode This field allows for the selection of the filter mo...

Страница 209: ...etwork and Subnet Mask will be filtered Otherwise routes within the Networks and Subnets will be filtered Export to other BGP Profile When this box is checked routes learnt from this BGP profile will be exported to other BGP profiles Export to OSPF When this box is checked routes learnt from this BGP profile will be exported to the OSPF routing protocol ...

Страница 210: ...IPsec Remote User Access Settings Pre shared Key Enter your pre shared key in the text field Please note that remote devices will need this preshared key to access the Balance Listen On This setting is for specifying the WAN IP addresses that allow remote user access Disable Weak Ciphers Click the button to show and enable this option When checked weak ciphers such as 3DES will be disabled Continu...

Страница 211: ...tworks PPTP has many well known security issues Continue to configure authentication method 23 4 Authentication Methods Authentication Method Connect to Network Select the VLAN network for remote users to enable remote user access on Authentication Determine the method of authenticating remote users User accounts This setting allows you to define the Remote User Accounts Click Add to input usernam...

Страница 212: ...s to allow for LDAP server authentication Radius Server Enter the matching Radius server details to allow for Radius server authentication Active Directory Enter the matching Active Directory details to allow for Active Directory server authentication ...

Страница 213: ...cally where there is a drop in connection configured on a LAN bypass port In the diagram the WAN ports of each Pepwave router connect to the router and to the modem Both Pepwave routers connect to the same LAN switch via a LAN port An elaboration on the technical details of the implementation of the virtual router redundancy protocol VRRP RFC 3768 by Pepwave routers follows In an HA configuration ...

Страница 214: ...be configured as the slave Resume Master Role Upon Recovery This option is displayed when Master mode is selected in Preferred Role If this option is enabled once the device has recovered from an outage it will take over and resume its Master role from the slave unit Configuration Sync This option is displayed when Slave mode is selected in Preferred Role If this option is enabled and the Master S...

Страница 215: ...setting specifies the subnet mask of the LAN Important Note For Pepwave routers in NAT mode the virtual IP VIP should be set as the default gateway for all hosts on the LAN segment For example a firewall sitting behind the Pepwave router should set its default gateway as the virtual IP instead of the IP of the master router In drop in mode no other configuration needs to be set ...

Страница 216: ...ty 24 2 Certificate Manager This section allows for certificates to be assigned to the local VPN Web Admin SSL Captive Portal SSL OpenVPN CA Wi Fi WAN Client certificate and Wi Fi WAN CA Certificate The following knowledge base article describes how to create self signed certificates and import it to a Peplink Product ...

Страница 217: ...ecified after selecting Enable DNS Forwarding When this option is enabled all outgoing DNS lookups will be intercepted and redirected to the built in DNS name server If any LAN device is using the DNS name servers of a WAN connection you may want to enable this option to enhance the DNS availability without modifying the DNS server setting of the clients The built in DNS name server will distribut...

Страница 218: ...r a WAN connection SMTP connections for the WAN will be simply be forwarded to the connection s original destination Note If you want to route all SMTP connections only to particular WAN connection s you should create a custom rule in outbound policy see Section 14 2 24 3 2 Web Proxy Forwarding When this feature is enabled the Pepwave router will intercept all outgoing connections destined for the...

Страница 219: ... to the router and then specify the IP Address and Port of the server you wish to forward to the service to 24 4 Service Passthrough Service passthrough settings can be found at Advanced Misc Settings Service Passthrough Some Internet services need to be specially handled in a multi WAN environment Pepwave routers can handle these services such that Internet applications do not notice being behind...

Страница 220: ... In a multi WAN situation they must be routed to the same WAN connection Otherwise problems will arise in transferring files By default the Pepwave router monitors TCP control connections on port 21 for any FTP connections and binds TCP connections of the same FTP session to the same WAN If you have an FTP server listening on a port number other than 21 you can check Define custom control ports an...

Страница 221: ...rminal block The RS 232 serial interface can be used to connect to a serial device and make it accessible over an TCP IP network The serial interface can be enabled and parameters can be set on the web admin page under Advanced UART Make sure they match the serial device you are connecting to ...

Страница 222: ... 8 CTS Pin 9 The RS232 serial interface is not an isolated RS232 External galvanic isolation may be added if required Be sure to check whether your serial cable is a null modem cable commonly known as crossover cable or a straight through cable If in doubt swap Rx and Tx and RTS and CTS at the other end and give it another go Once connected your serial device should be accessible on your Pepwave M...

Страница 223: ...send GPS reports in NMEA format select one or more sentence types for sending the data GPRMC GPGGA GPVTG GPGSA and GPGSV Vehicle ID The vehicle ID will be appended in the last field of the NMEA sentence Note that the NMEA sentence will become customized and non standard TAIP Sentence Type TAIP ID optional If you ve chosen to send GPS reports in TAIP format select one or more sentence types for sen...

Страница 224: ...he engine of a vehicle is turned off Ignition Sensing installation Functoin Colour Wire I O optional Brown IGN I P connected to positive feed on the ignition Orange DC IN connected to permanent negative feed ground Black DC IN connected to permanent positive feed power 12VDC 2A Red Currently not functional will be used for additional features in future firmware ...

Страница 225: ...Connectivity diagram for devices with 4 pin connector Connectivity diagram for devices with terminal block connection ...

Страница 226: ...ut a digital output or an analog input Digital Input the connection supports input sensing it reads the external input and determines if the settings should be High on or Low off Digital Output when there is a healthy WAN connection the output pin is marked as High on Otherwise it will be marked as Low off Note The Digital Output state on off upon rebooting the device may vary depending on the mod...

Страница 227: ...t connected devices always receive the correct time Compatible with BR1 ENT 700 HW3 HD2 4 Transit NTP Server setting can be found via Advanced Misc Settings NTP Server Time Settings can be found at System Time Time Settings 24 9 Grouped Networks Advanced Grouped Networks allows to configure destination networks in grouped format Select Add group to create a new group with single IPaddresses or sub...

Страница 228: ...The created network groups can be used in outbound policies firewall rules ...

Страница 229: ...ector or Appendix B for more details on FusionSIM Manual Remote SIM Host Settings Remote SIM Host Settings Active LAN Discovery Check this box to enable Auto LAN discovery of the remote SIM server Remote SIM Host Enter the public IP address of the SIM Injector If you enter IP addresses here it is not necessary to tick the Auto LAN Discovery box above You may define the Remote SIM information by cl...

Страница 230: ...ming Enables data roaming on this particular SIM card Operator Settings for LTE HSPA EDGE GPRS Only This setting allows you to configure the APN settings of your connection If Auto is selected the mobile operator should be detected automatically The connected device will be configured and connection will be made automatically If there is any difficulty in making a connection you may select Custom ...

Страница 231: ... Data USSD is a protocol used by mobile phones to communicate with their service provider s computers One of the most common uses is to query the available balance Enter your USSD code under the USSD Code text field and click Submit You will receive a confirmation To check the SMS response click Get After a few minutes you will receive a response to your USSD code ...

Страница 232: ...SMS The SMS option allows you to read SMS text messages that have been sent to the SIM in your Pepwave router ...

Страница 233: ...d DHCP option CAPWAP Access Controller addresses field 138 will be added to the DHCP server A local DNS record AP Controller will be added to the local DNS proxy Sync Method As soon as possible Progressively One at a time Permitted AP Access points to manage can be specified here If Any is selected the AP controller will manage any AP that reports to it If Approved List is selected only APs with s...

Страница 234: ...n all outgoing packets generated from this wireless network i e packets that travel from the Wi Fi segment through the Pepwave AP One unit to the Ethernet segment via the LAN port The default value of this setting is 0 which means VLAN tagging is disabled instead of tagged with zero Broadcast SSID This setting specifies whether or not Wi Fi clients can scan the SSID of this wireless network Broadc...

Страница 235: ...manner in which clients are physically connected to the network Layer 2 Isolation A Layer 2 refers to the second layer in the ISO Open System Interconnect model When this option is enabled clients on the same VLAN SSID or subnet are isolated to that VLAN SSID or subnet which can enhance security Traffic is passed to the upper communication layer s By default the setting is disabled Maximum Number ...

Страница 236: ...P which is NOT WPA3 PSK capable the AP Controller will not push those WPA3 and WPA2 WPA3 SSID to that AP Access Control Restricted Mode The settings allow the administrator to control access using MAC address filtering Available options are None Deny all except listed and Accept all except listed MAC Address List Connection coming from the MAC addresses in this list will be either denied or accept...

Страница 237: ...Support is available on devices running 802 11ac Wi Fi 5 and above Along with the AP Controller mesh network extensions can be established which can expand network coverage Note that the Wireless Mesh settings need to match the Mesh ID and Shared Key of the other devices on the same selected frequency band To create a new Wireless Mesh profile go to AP Wireless Mesh and click Add Wireless Mesh Set...

Страница 238: ... use this AP profile You can also select the frequencies at which each network will transmit Please note that the Pepwave MAX does not detect whether the AP is capable of transmitting at both frequencies Instructions to transmit at unsupported frequencies will be ignored by the AP Operating Country This drop down menu specifies the national regional regulations which the AP ...

Страница 239: ...hen the country is selected as Japan with protocol 802 11b If Auto is set the system will perform channel scanning based on the scheduled time set and choose the most suitable channel automatically Auto Channel Update Indicate the time of day at which update automatic channel selection Output PowerA This drop down menu determines the power at which the AP under this profile will broadcast When fix...

Страница 240: ... The interval unit is measured in milliseconds RTS ThresholdA This field provides the option to set the minimum packet size for the unit to send an RTS using the RTS CTS handshake Setting 0 disables this feature Fragmentation ThresholdA Determines the maximum size in bytes that each packet fragment will be broken down into Set 0 to disable fragmentation Distance Time ConverterA Select the distance...

Страница 241: ...rection This option will be available if you have chosen HTTPS as the Web Access Protocol With this enabled any HTTP access to the web admin will redirect to HTTPS automatically Admin User Name This field specifies the administrator username of the web admin It is set as admin by default Admin Password This field allows you to specify a new administrator password You may also click the Generate bu...

Страница 242: ... Available options are 802 11ng and 802 11na By default 802 11ng is selected Channel This option allows you to select which 802 11 RF channel will be used Channel 1 2 412 GHz is selected by default Channel Width Auto 20 40 MHz and 20 MHz are available The default setting is Auto 20 40 MHz which allows both widths to be used simultaneously Output Power This option is for specifying the transmission...

Страница 243: ...lot TimeA This field is for specifying the wait time before the Router transmits a packet By default this field is set to 9 µs ACK TimeoutA This field is for setting the wait time to receive an acknowledgement packet before performing a retransmission By default this field is set to 48 µs Frame AggregationA This option allows you to enable frame aggregation to increase transmission throughput Guar...

Страница 244: ...z Clicking either box will toggle the display of information for that frequency By default the graphs display the number of clients and data usage for both 2 4GHz and 5 GHz frequencies SSID The colored boxes indicate the SSID to display information for Clicking any colored box will toggle the display of information for that SSID By default all the graphs show information for all SSIDs No of APs Th...

Страница 245: ...e over any line on the graph to see the data usage by each SSID for that point in time Use the buttons next to Zoom to select the time scale you wish to view In addition you could use the sliders at the bottom to further refine your timescale Events This event log displays all activity on your AP network down to the client level Click View Alerts to see only alerts and click the More link for addi...

Страница 246: ... Point Usage AP Name Serial Number This field enables you to quickly find your device if you know its name or serial number Fill in the field to begin searching Partial names and serial numbers are supported Online Status This button toggles whether your search will include offline devices Managed Wireless Devices ...

Страница 247: ...the client will broadcast Click the icon to see a graph displaying usage Click any point in the graphs to display detailed usage and client information for that device using that SSID at that point in time On the Data Usage by menu you can display the information by SSID or by AP send receive rate Click the Event tab next to Wireless Usage to view a detailed event log for that particular device ...

Страница 248: ...26 3 Wireless SSID In depth SSID reports are available under AP Controller Status Wireless SSID Click the blue arrow on any SSID to obtain more detailed usage information on each SSID ...

Страница 249: ...of your wireless distribution system WDS or Mesh and track activity by MAC address by navigating to AP Controller Status Mesh WDS This table shows the detailed information of each AP including protocol transmit rate sent received signal strength and duration ...

Страница 250: ...26 5 Wireless Client You can search for specific Wi Fi users by navigating to AP Controller Status Wireless Client ...

Страница 251: ...26 6 Nearby Device A listing of near devices can be accessed by navigating to AP Controller Status Nearby ...

Страница 252: ...ss will result in a popup with information on how this device was detected Click the icons and the device will be moved to the bottom table of identified devices 26 7 Event Log You can access the AP Controller Event log by navigating to AP Controller Status Event Log ...

Страница 253: ...ink for additional records 27 Toolbox Tools for managing firmware packs can be found at AP Toolbox Firmware Packs Here you can manage the firmware of your AP Clicking on will result in information regarding each firmware pack To receive new firmware packs you can click Check for Updates to download new packs or you can click Manual Upload to manually upload a firmware pack Click Default to define ...

Страница 254: ...t Before the session expires you may click the Logout button in the web admin to exit the session 0 hours 0 minutes signifies an unlimited session time This setting should be used only in special situations as it will lower the system security level if users do not log out before closing the browser The default is 4 hours 0 minutes For security reasons after logging in to the web admin Interface f...

Страница 255: ...er terminates its access to the web admin interface By default it is set to 4 hours Authentication by RADIUS With this box is checked the web admin will authenticate using an external RADIUS server Authenticated users are treated as either admin with full read write permission or user with read only access Local admin and user accounts will be disabled When the device is not able to communicate wi...

Страница 256: ...nting access to LAN and WAN clients or to LAN clients only Security This option is for specifying the protocol s through which the web admin interface can be accessed HTTP HTTPS HTTP HTTPS Web Admin Port This field is for specifying the port number on which the web admin interface can be accessed Web Admin Access This option is for specifying the network interfaces through which the web admin inte...

Страница 257: ...ere w x y z is an IP address e g 192 168 0 0 and m is the subnet mask in CIDR format which is between 0 and 32 inclusively For example 192 168 0 0 24 To define multiple subnets separate each IP subnet one in a line For example 192 168 0 0 24 10 8 0 0 16 Allowed WAN IP Address es This is to choose which WAN IP address es the web server should listen on 28 2 Firmware Web admin interface automaticall...

Страница 258: ...l depend on your internet connection s speed The firmware will now be applied to the router The amount of time it takes for the firmware to upgrade will also depend on the router that s being upgraded Upgrading the firmware will cause the router to reboot Web admin interface install updates manually In some cases a special build may be provided via a ticket or it may be found in the forum Upgradin...

Страница 259: ...e Upgrade section Navigate to the location that the firmware was downloaded to select the img file and click the Open button Click on the Manual Upgrade button to start the upgrade process A prompt will be displayed advising to download the Current Active Configuration Please click on the underlined download text After downloading the current config click the Ok button to start the upgrade process...

Страница 260: ...he Pepwave router s event log and e mail notifications Check Show all to show all time zone options Time Server This setting specifies the NTP network time server to be utilized by the Pepwave router 28 4 Schedule Enable and disable different functions such as WAN connections outbound policy and firewalls at different times based on a user scheduled configuration profile The settings for this are ...

Страница 261: ... to choose pre defined schedules as your starting point Please note that upon selection previous changes on the schedule map will be deleted Schedule Map Click on the desired times to enable features at that time period You can hold your mouse for faster entry 28 5 Email Notification Email notification functionality provides a system administrator with up to date information on network status The ...

Страница 262: ...on Security This setting specifies via a drop down menu one of the following valid Connection Security None STARTTLS SSL TLS SMTP Port This field is for specifying the SMTP port number By default this is set to 25 If Connection Security is selected STARTTLS the default port number will be set to 587 If Connection Security is selected SSL TLS the default port number will be set to 465 You may custo...

Страница 263: ...notifications For multiple recipients separate each email addresses using the enter key After you have finished setting up email notifications you can click the Test Email Notification button to test the settings before saving After Test Email Notification is clicked you will see this screen to confirm the settings Click Send Test Notification to confirm In a few seconds you will see a message wit...

Страница 264: ......

Страница 265: ...t the specified remote syslog server Remote Syslog Host This setting specifies the IP address or hostname of the remote syslog server Push Events The Pepwave router can also send push notifications to mobile devices that have our Mobile Router Utility installed Check the box to activate this feature URL Logging This setting is to enable event logging at the specified log server URL Logging Host Th...

Страница 266: ...rd that can be used to collect information about the Pepwave router SNMP configuration is located at System SNMP SNMP Settings SNMP Device Name This field shows the router name defined at System Admin Security SNMP Port This option specifies the port which SNMP will use The default port is 161 SNMPv1 This option allows you to enable SNMP version 1 SNMPv2 This option allows you to enable SNMP versi...

Страница 267: ...ubnet mask To define a user name for SNMPv3 click Add SNMP User in the SNMPv3 User Name table upon which the following screen is displayed SNMPv3 User Settings User Name This setting specifies a user name to be used in SNMPv3 Authentication Protocol This setting specifies via a drop down menu one of the following valid authentication protocols NONE MD5 SHA When MD5 or SHA is selected an entry fiel...

Страница 268: ... supports SMS and note that some plans may incur additional charges for this SMS Control can reboot devices and configure cellular settings over signalling channels even if the modem does not have a data connection For details of supported SMS command sets please refer to our knowledge base SMS Control Settings Enable Click the checkbox to enable the SMS Control Password This setting sets the pass...

Страница 269: ...ll be sent to the system if you enable the features in the system Alternately you could also privately host InControl Simply check the box beside the Privately Host InControl open and enter the IP Address of your InControl Host You can sign up for an InControl account at https incontrol2 peplink com You can register your devices under the account monitor their status see their usage reports and re...

Страница 270: ...mputer and then click Upload The new settings can then be applied by clicking the Apply Changes button on the page header or you can cancel the procedure by pressing discard on the main page of the web admin interface Upload Configurations from High Availability Pair In a high availability HA configuration a Pepwave router can quickly load the configuration of its HA counterpart To do so click the...

Страница 271: ...ter can equip with two copies of firmware Each copy can be a different version You can select the firmware version you would like to reboot the device with The firmware marked with Running is the current system boot up firmware Please note that a firmware upgrade will always replace the inactive firmware partition ...

Страница 272: ...n specify the number of pings in the field Number of times to a maximum number of 10 times Packet Size can be set to a maximum of 1472 bytes The ping utility is located at System Tools Ping illustrated below Tip A system administrator can use the ping utility to manually check the connectivity of a particular LAN WAN connection ...

Страница 273: ...s Traceroute Tip A system administrator can use the traceroute utility to analyze the connection path of a LAN WAN connection 29 3 PepVPN Test The PepVPN Test tool can help to test the throughput between different VPN peers You can define the Test Type Direction and Duration of the test and press Go to perform the throughput test The VPN test utility is located at System Tools PepVPN Test illustra...

Страница 274: ...he drop down list and click Send to send a magic packet 29 5 CLI Command Line Interface Support The CLI command line interface can be accessed via SSH This field enables CLI support The below settings specify which TCP port and which interface s should accept remote SSH CLI access The user name and password used for remote SSH CLI access are the same as those used for web admin access ...

Страница 275: ...e specified in the Device Name field located at System Admin Security Model This shows the model name and number of this device Product Code If your model uses a product code it will appear here Hardware Revision This shows the hardware version of this device Serial Number This shows the serial number of this device ...

Страница 276: ...ned to the Pepwave router appears here Uptime This shows the length of time since the device has been rebooted System Time This shows the current system time OpenVPN Client Profile Link to download OpenVpn Client profile when this is enabled in Remote User Access Diagnostic Report The Download link is for exporting a diagnostic report file required for system investigation Remote Assistance Click ...

Страница 277: ...e GPS enabled devices export real time location data in NMEA format through the LAN IP address at TCP port 60660 It is accessible from the LAN or over a SpeedFusion connection To access the data via a virtual serial port install a virtual serial port driver Visit http www peplink com index php view faq id 294 to download the driver 30 3 Active Sessions Information on active sessions can be found a...

Страница 278: ...tion This screen also indicates the number of sessions initiated by each WAN port In addition you can see which clients are initiating the most sessions You can also perform a filtered search for specific sessions You can filter by subnet port protocol and interface To perform a search navigate to Status Active Sessions Search ...

Страница 279: ...onnection on the Pepwave router A filter is available to sort active session information Enter a keyword in the field or check one of the WAN connection boxes for filtering 30 4 Client List The client list table is located at Status Client List It lists DHCP and online client IP addresses ...

Страница 280: ...tus WINS Client The WINS client table lists the IP addresses and names of WINS clients This option will only be available when you have enabled the WINS server navigation Network Interfaces LAN The names of clients retrieved will be automatically matched into the Client List see previous section Click Flush All to flush all WINS client records 30 6 UPnP NAT PMP The table that shows the forwarded p...

Страница 281: ...records click Delete All on the right hand side below the table Important Note UPnP NAT PMP records will be deleted immediately after clicking the button or Delete All without the need to click Save or Confirm 30 7 OSPF RIPv2 Shows status of OSPF and RIPv2 30 8 BGP Shows status of BGP ...

Страница 282: ...usionTM status information is located at Status SpeedFusionTM Details about SpeedFusionTM connection peers appears as below Click on the corresponding peer name to explore the WAN connection s status and subnet information of each VPN peer ...

Страница 283: ......

Страница 284: ...ws you to run PepVPN Tests allowing throughput tests Peplink also published a whitepaper about Speedfusion which can be downloaded from the following url http download peplink com resources whitepaper speedfusion and best practices 2019 pdf 30 10Event Log Event log information is located at Status Event Log ...

Страница 285: ...The log section displays a list of events that has taken place on the Pepwave router Check Auto Refresh to refresh log entries automatically Click the Clear Log button to clear the log ...

Страница 286: ...WAN Quality The Status WAN Quality allow to show detailed information about each connected WAN connection For cellular connections it shows signal strength quality throughput and latency for the past hour ...

Страница 287: ...is switched off e g LAN bypass is neither recorded nor shown 32 1 Real Time The Data transferred since installation table indicates how much network traffic has been processed by the device since the first bootup The Data transferred since last reboot table indicates how much network traffic has been processed by the device since the last bootup ...

Страница 288: ...usage for all WAN connections with the option of viewing each individual connection Select the desired connection to check from the drop down menu 32 3 Daily This page shows the daily bandwidth usage for all WAN connections with the option of viewing ...

Страница 289: ... selected to view the bandwidth usage of only a particular WAN connection The scale of the graph can be set to display megabytes MB or gigabytes GB All WAN Daily Bandwidth Usage 32 4 Monthly This page shows the monthly bandwidth usage for each WAN connection If you have enabled the Bandwidth Monitoring feature you can check the usage of each particular connection and view the information by Billin...

Страница 290: ...is not available if you have chosen to view the bandwidth of an individual WAN connection The scale of the graph can be set to display megabytes MB or gigabytes GB All WAN Monthly Bandwidth Usage ...

Страница 291: ...Ethernet WAN Monthly Bandwidth Usage Tip By default the scale of data size is in MB 1GB equals 1024MB ...

Страница 292: ... reset Note The LED status light blinks in RED 2 times and release the button green status light starts blinking Hold for approximately 20 seconds for factory reset Note The LED status light blinks in RED 3 times and release the button all WAN LAN port lights start blinking After the Pepwave router finishes rebooting the factory default settings will be restored Important Note All previous configu...

Страница 293: ... check for the latest Firmware version on the device s WEB configuration page A list of products that support FusionSIM can be found on the SIM Injector WEB page Please check under the section Supported models SIM Injector reset and login details How to reset a SIM Injector Hold the reset button for 5 10 seconds Once the LED status light turns RED the reset button can be released SIM Injector will...

Страница 294: ...g to access a cellular router IMPORTANT Cellular WAN will not fallback to the local SIM if it is configured to use the SIM Injector Configuring the SIM Injector 1 Connect the SIM Injector to the LAN port of the cellular router 2 Insert SIM cards into the SIM Injector The SIM cards will be automatically detected IMPORTANT SIM cards inserted into SIM Injector must not have a PIN code Note 1 The SIM ...

Страница 295: ...to LAN discovery checkbox and click Save and Apply Changes 5 Click Save and then Apply Changes Step 2 Enable RemoteSIM for the selected Cellular interface 2 Scroll down to Cellular settings 3 In the SIM Card section select Use Remote SIM Only 4 Enter configuration settings in Remote SIM Settings section Click on Scan nearby remote SIM server to show the serial number s of the connected SIM Injecto...

Страница 296: ...tep 3 Optional Custom SIM cards settings 1a For a Balance router go to the Network Top tab 1b For a MAX router go to the Advanced Top tab 2 Under Misc settings Left side tab find Remote SIM Management 3 Click on the Add Remote SIM button fill in all the required info and click Save This section allows defining custom requirements for a SIM card located in a certain SIM slot Enable Disable roaming ...

Страница 297: ... Additional configurations for Cellular Routers Step 1 Disable the DHCP server HD Dome 1 should act as a DHCP server HD Dome 2 should be configured to have a static IP address with DHCP disabled Both routers should be in the same subnet e g 192 168 50 1 and 192 168 50 2 1 Go to Network Top tab then Network Settings Left side tab and click on Untagged LAN This will open up the LAN settings page 2 C...

Страница 298: ...AN 2 The image below shows the values that need to be changed to create a new VLAN Note set different IP addresses for each HD dome e g 192 168 10 1 and 192 168 10 2 3 Click Save and Apply Changes 4 Go to Network Top tab then Port Settings Left side tab 5 Set the Port Type to Access and set VLAN to Untagged LAN see picture below 6 Click Save and Apply Changes Configuration requirements for the mai...

Страница 299: ... as a DHCP client WAN 1 will automatically get the Gateway IP address from HD Dome 1 Configure WAN 2 as a Static IP and set it to 192 168 50 12 Configure WAN 2 Gateway to 192 168 50 2 Same as the HD Dome 2 s IP address ...

Страница 300: ...s are provided to the HD Domes via the main router In this example the Remote SIM Proxy functionality needs to be enabled on the main router Notes HD Dome can be replaced with any other cellular router that supports RemoteSIM It is recommended to use Peplink Balance series or X series routers as the main router ...

Страница 301: ...rent subnets e g 192 168 50 1 24 and 192 168 100 1 24 Note please make sure the Peplink router is running Firmware 8 1 0 or above 1 Open the main router WEB interface and change From IP address cgi bin MANGA index cgi to IP address cgi bin MANGA support cgi This will open the support cgi page 2 Scroll down to find Remote SIM Proxy and click on click to configure that is located next to it 3 Check ...

Страница 302: ...he SIM Injector It can be another Internet connection via Ethernet or Fiber if possible or a secondary cellular interface with a local SIM Ignite SIM Due to its high latency it is not recommended to use satellite WAN for connecting to a SIM Injector in remote locations SIM Injector configuration is the same as in Scenario 1 Cellular Router configuration Step 1 Enable the SIM Injector communication...

Страница 303: ...jector and click Save and Apply Changes Notes Do NOT check Auto LAN Discovery Do NOT add a SIM Injector serial number to the Remote SIM Host field Step 2 RemoteSIM and custom SIM card settings configurations are the same as in Scenario 1 ...

Страница 304: ...r settings If you can see the Remote SIM Settings section then the cellular router supports Remote SIMs Monitor the status of the Remote SIM 1 Go to Network Top tab then WAN Left side tab and click Details on the cellular WAN which was configured to use RemoteSIM 2 Check the WAN Connection Status section Within the cell WAN details there is a section for Remote SIM SIM card IMSI SIM Injector seria...

Страница 305: ...uipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment IEEE 802 11b or 802 11g operation of this product in the U S A is firmware limite...

Страница 306: ......

Страница 307: ......

Страница 308: ... UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 309: ...CE Statement for Pepwave Routers MAX BR1 Mini for MC7455 ...

Страница 310: ......

Страница 311: ... UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 312: ...ubi meme si le brouillage est susceptible d en compromettre le fonctionnement This product meets the applicable Innovation Science and Economic Development Canada technical specifications Le présent produit est conforme aux spécifications techniques applicables d Innovation Sciences et Développement économique Canada This device complies with the ISED radiation exposure limit set forth for an unco...

Страница 313: ...he instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense IC Warning This device contains licence exempt transmitter s receiver s that comply with Innovation Science and Economic Development Canada s lice...

Страница 314: ...isted below with the maximum permissible gain indicated Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device Le present emetteur radio 20682 P1930LITER6 a ete approuve par Innovation Sciences et Developpement economique Canada pour fonctionner avec les types d antenne enumeres ci dessou...

Страница 315: ...r s authority to operate this equipment Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 24cm between the radiator your body Industry Canada Statement For MAX BR1 MK2 This product meets the applicable Innovation Science and Economic Development Cana...

Страница 316: ...afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux ii Le gain maximal d antenne permis pour les dispositifs avec antenne s amovible s utilisant la bande 5725 5850 MHz doit se conformer à la limitation P I R E spécifiée pour l exploitation point à point et non point à point selon le cas En outre les utilisateurs devraient aussi être...

Страница 317: ...CE Statement for Pepwave Routers MAX BR1 MK2 ...

Страница 318: ......

Страница 319: ...GPP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 320: ...and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the us...

Страница 321: ...epter tout brouillage radioelectrique subi meme si le brouillage est susceptible d en compromettre le fonctionnement This device complies with the ISED radiation exposure limit set forth for an uncontrolled environment This device should be installed and operated with minimum distance 20cm between the radiator your body Cet équipement est conforme avec l exposition aux radiations ISED définies pou...

Страница 322: ...CE Statement for Pepwave Routers MAX BR1 Classic for MC7455 ...

Страница 323: ......

Страница 324: ... UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 325: ...CE Statement for Pepwave Routers MAX BR1 Classic for EC25 E ...

Страница 326: ......

Страница 327: ... 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body https www peplink com ...

Страница 328: ...d operated with minimum distance 20cm between the radiator your body Any Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ISED Warning Statement For MAX HD4 MBX Industry Canada Statement This device complies with Industry Canada s licence exempt RSSs Operation is subject to the following two conditions ...

Страница 329: ...ance sont désignés utilisateurs principaux c à d qu ils ont la priorité pour les bande 5725 5850 MHz et que ces radars pourraient causer du brouillage et ou des dommages aux dispositifs LAN EL IC Radiation Exposure Statement This equipment complies with Innovation Science and Economic Development Canada RF exposure limits set forth for an uncontrolled environment This equipment should be installed...

Страница 330: ...CE Statement for Pepwave Routers MAX HD4 MBX For EM7565 ...

Страница 331: ......

Страница 332: ...PP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 333: ...CE Statement for Pepwave Routers MAX HD2 MBX MAX HD4 MBX For LM960A18 ...

Страница 334: ......

Страница 335: ...PP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 336: ... FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 50 centimeters between the radiator and your body Industry Canada Statement MAX HD2 This product meets the applicable Innovation Science and Economic Development Canada technical specifications Le présent produit est conforme aux spécifications tech...

Страница 337: ... I R E spécifiée pour l exploitation point à point et non point à point selon le cas En outre les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux c à d qu ils ont la priorité pour les bande 5725 5850 MHz et que ces radars pourraient causer du brouillage et ou des dommages aux dispositifs LAN EL Radiation Exposure Stat...

Страница 338: ......

Страница 339: ...CE Statement for Pepwave Routers MAX HD2 For MC7455 ...

Страница 340: ......

Страница 341: ...GPP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 342: ...CE Statement for Pepwave Routers MAX HD2 For MC7565 ...

Страница 343: ......

Страница 344: ...GPP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 345: ...20mm head diameter 6mm head thickness 2 4mm The Pepwave MAX BR1 Classic requires four screws for wall mounting Output of the external power source shall complied with ES1 and ES2 requirements output rating 10 30 Vdc minimum 12W DC Jack or POE injector with minimum ambient temperature 65 altitude 5000m and evaluated in accordance to UL EN IEC 60950 1 and or UL EN IEC 62368 1 Ensure to connect the p...

Страница 346: ...tter End users and installers must be provide with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment ...

Страница 347: ...nces radio RF Cet equipement est conforme avec l exposition aux radiations IC definies pour un environnement noncontrole Cet equipement doit etre installe et utilise a une distance minimum de 23 cm entre le radiateuret votre corps Cet emetteur ne doit pas etre co localisees ou operant en conjonction avec une autreantenne ou transmetteur Les utilisateurs finaux et les installateurs doivent etre inf...

Страница 348: ...antenna gain for 5GHz 5725 5850 MHz 4 73 dBi Battery Caution Statement Risk of explosion if the battery is replaced by an incorrect type ...

Страница 349: ...CE Statement for Pepwave Routers MAX BR1 Pro 5G ...

Страница 350: ......

Страница 351: ... with CE radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com FCC Requirements for Operation in the United States Federal Communications Commission FCC Compliance Notice ...

Страница 352: ...armful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Industry Canada Statement MAX...

Страница 353: ...energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modifications not expressly approved by the party responsible for...

Страница 354: ...cations Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment Industry Canada Statement MAX HD2 IP67 MAX HD2 Mini MAX HD2 Dome MAX HD4...

Страница 355: ...CE Statement for Pepwave Routers MAX HD2 IP67 ...

Страница 356: ......

Страница 357: ...This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 358: ...CE Statement for Pepwave Routers MAX HD1 Dome ...

Страница 359: ......

Страница 360: ...This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 361: ...CE Statement for Pepwave Routers MAX HD2 Dome ...

Страница 362: ......

Страница 363: ...This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 364: ...CE Statement for Pepwave Routers MAX BR1 ESN ...

Страница 365: ......

Страница 366: ... UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 367: ...tatement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 40 centimeters between the radiator and your body Industry Canada Statement MAX HD4 This product meets the applicable Innovation Science and Economic Development Canada technical specifications Le present produit...

Страница 368: ...tes mobiles utilisant les memes canaux ii Le gain maximal d antenne permis pour les dispositifs avec antenne s amovible s utilisant la bande 5725 5850 MHz doit se conformer a la limitation P I R E specifiee pour l exploitation point a point et non point a point selon le cas En outre les utilisateurs devraient aussi etre avises que les utilisateurs de radars de haute puissance sont designes utilisa...

Страница 369: ...CE Statement for Pepwave Routers MAX HD4 ...

Страница 370: ......

Страница 371: ...efer 3GPP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 372: ...CE Statement for Pepwave Routers MAX HD4 IP67 ...

Страница 373: ......

Страница 374: ...This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 375: ...CE Statement for Pepwave Routers SpeedFusion Engine ...

Страница 376: ......

Страница 377: ...EC25 E module This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 378: ...uipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Operations in the 5 15 5 25GHz band are restricted to indoor usage only Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 24 cen...

Страница 379: ...ejudiciable aux systemes de satellites mobiles utilisant les memes canaux ii Le gain maximal d antenne permis pour les dispositifs avec antenne s amovible s utilisant la bande 5725 5850 MHz doit se conformer a la limitation P I R E specifiee pour l exploitation point a point et non point a point selon le cas En outre les utilisateurs devraient aussi etre avises que les utilisateurs de radars de ha...

Страница 380: ......

Страница 381: ......

Страница 382: ...PP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 383: ...CE Statement for Pepwave Routers MAX Transit For LM960A18 ...

Страница 384: ......

Страница 385: ...PP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 386: ...sly approved by the party responsible for compliance could void your authority to operate the equipment Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body Industry Canada Statement MAX Transit ...

Страница 387: ...r use with this device Antenna types Replacement Antenna Antenna gain in dBi 5 33 dBi Innovation Sciences et Developpement economique Canada a approuve l utilisation de ce transmetteur radio avec les types d antenne enumeres ci dessous le gain maximal admissible etant indique Les types d antennes non inclus dans cette liste qui ont un gain superieur au gain maximal indique pour tout type liste son...

Страница 388: ...CE Statement for Pepwave Routers MAX Transit Mini ...

Страница 389: ......

Страница 390: ...UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20 cm between the radiator your body contact as https www peplink com ...

Страница 391: ...This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 23 centimeters between the radiator and your body Industry Canada Statement MAX BR1 PRO MAX BR2 PRO UBR LTE This product meets the applicable Innovation Science and Economic Development Canada technical specifications Le ...

Страница 392: ...ence and or damage to LE LAN devices iii where applicable antenna type s antenna models s and worst case tilt angle s necessary to remain compliant with the e i r p elevation mask requirement set forth in section 6 2 2 3 shall be clearly indicated i Le dispositif fonctionnant dans la bande 5150 5250 MHz est reserve uniquement pour utilisation a l interieur afin de reduire les risques de brouillage...

Страница 393: ...ipement est conforme avec l exposition aux radiations ISED definies pour un environnement non controle Cet equipement doit etre installe et utilise a une distance minimum de 23 cm entre le radiateur et votre corps ...

Страница 394: ...CE Statement for Pepwave Routers MAX BR1 PRO MAX BR2 PRO UBR LTE ...

Страница 395: ......

Страница 396: ...PP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your body contact as https www peplink com ...

Страница 397: ...requency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modifications not expressly approved by the party respon...

Страница 398: ...CE Statement for Pepwave Routers MAX BR1 IP55 ...

Страница 399: ......

Страница 400: ...m WWAN Refer 3GPP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 50cm between the radiator your body contact as https www peplink com ...

Страница 401: ...CE Statement for Pepwave Routers MAX BR2 IP55 ...

Страница 402: ......

Страница 403: ...m WWAN Refer 3GPP TS 36 521 1 UE Power class This equipment complies with CE radiation exposure limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with a minimum distance of 50cm between the radiator your body contact as https www peplink com ...

Страница 404: ...Specification MAX Series MAX 700 MAX HD2 MAX HD2 Media Fast MAX HD2 Mini MAX HD2 HD4 MBX MAX BR1 ENT MAX BR1NT MAX HD4 MAX HD4 Media Fast MediaFast 200 Output Rating 5V DC 2A 5V DC 2A 5V DC 2A 5V DC 0 5A 5V DC 2A 5V DC 2A ...

Отзывы: