Installation
Fiber Optic Specifications
The TX marking on the interface indicates the transmitted signal from the TCU/PCU to the
connected device (switch). Connect the RX of the fiber-optic cable here.
The RX marking shows the receiving signal of the TCU/PCU from the conneted device
(switch). Connect the TX of the fiber-optic cable here.
Optional Fiber-Optic Interface
TX
RX
Note!
When the fiber-optic interface is installed, no terminal connections are available at X2.
Minimum cable requirement
OM2 (50/125
µ
m)
Data rate
1 Gb
Max. distance
550 m
Mode
Multimode
Category
1000-BASE-SX
Link budget
3 dB (in addition to cabling with 550 m
OM2)
—
if counterpart uses Horizon GXP,
AFBR-5710 transceiver, 1002MC/SX media
converter, or equivalent
Note!
The fiber-optic interface of the TCU/PCU can be connected and safely operated with other
devices that comply with Class 1 limits in accordance with IEC 60825-1 or that are classified as
inherently safe optical radiation "op is" in accordance with IEC 60079-28.