Installation
2
018-
11
15
Terminal Compartment Ex e
X1: Power 24 V DC / USB Ex e
The table below gives an overview of the 2 color schemes:
The Ethernet terminal assignment can be done either by EIA/TIA-568A or by EIA/TIA-568B
color scheme. Choose the color scheme according to your factory standard.
We recommend using S/FTP Cat.7 Ethernet cables to achieve best signal quality and longest
communication distances.
X2: Ethernet Ex e
Terminal
X1.1
V+
Power Supply
X1.2
V+
X1.3
GND
X1.4
GND
X1.5
VCC
USB Ex e
X1.6
D-
X1.7
D+
X1.8
GND
Terminal
Ethernet Terminal
Assignment acc.
EIA/TIA-568B
Ethernet Terminal
Assignment acc.
EIA/TIA-568A
X2.1
Tx+/D1+
white / orange
line
white / green line
OR fully green
X2.2
Tx-/D1-
orange / white
line OR fully orange
green / white line
X2.3
D3+
blue / white line
OR fully blue
blue / white line
OR fully blue
X2.4
D3-
white / blue line
white / blue line
X2.5
RX+/D2+
white / green line
white / orange
line
X2.6
RX-/D2-
green / white line
OR fully green
orange / white
line OR fully orange
X2.7
D4+
white / brown line
white / brown line
X2.8
D4-
brown / white line
OR fully brown
brown / white line
OR fully brown